메뉴 건너뛰기




Volumn 26, Issue 3, 2003, Pages 97-103

Boron neutron capture therapy (BNCT) for malignant melanoma with special reference to absorbed doses to the normal skin and tumor

Author keywords

Absorbed dose; BNCT; BPA; Dose optimization; Dosimetry; Melanoma

Indexed keywords

DOSIMETRY; IRRADIATION; PATIENT TREATMENT; PHARMACOKINETICS; RADIATION; SKIN; TUMORS;

EID: 10744226723     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178777     Document Type: Article
Times cited : (57)

References (21)
  • 1
    • 33745945620 scopus 로고
    • The role of chemistry in the development of boron neutron capoture therapy of cancer
    • Hawthorne, M. F. The role of chemistry in the development of boron neutron capoture therapy of cancer, Angew Chem Int Ed Engl 32:950-984, 1993.
    • (1993) Angew Chem Int Ed Engl , vol.32 , pp. 950-984
    • Hawthorne, M.F.1
  • 2
  • 4
    • 0002230191 scopus 로고    scopus 로고
    • Selective thermal neutron capture therapy of cancer cells using their specific metabolic activities-melanoma as prototype
    • In: Mishima Y, ed.; New York, London, Plenum Press
    • Mishima, Y. Selective thermal neutron capture therapy of cancer cells using their specific metabolic activities-melanoma as prototype, In: Mishima Y, ed. Cancer Neutron Capture Therapy, New York, London, Plenum Press, 1-26, 1996.
    • (1996) Cancer Neutron Capture Therapy , pp. 1-26
    • Mishima, Y.1
  • 5
    • 0024539685 scopus 로고
    • Improvement of solubility of p-boronophenylalanine by complex formation with monosaccharides
    • Yoshino, K., Suzuki, K., Mori, Y., et al. Improvement of solubility of p-boronophenylalanine by complex formation with monosaccharides. Strahlenther Oncol, 165:127-129, 1989.
    • (1989) Strahlenther Oncol , vol.165 , pp. 127-129
    • Yoshino, K.1    Suzuki, K.2    Mori, Y.3
  • 6
    • 0020494826 scopus 로고
    • 10B concentration in tissue for neutron capture therapy by prompt gamma-ray spectrometry
    • 10B concentration in tissue for neutron capture therapy by prompt gamma-ray spectrometry, Nucl Inst Method 204:525-531, 1982.
    • (1982) Nucl Inst Method , vol.204 , pp. 525-531
    • Kobayashi, T.1    Kanda, K.2
  • 7
    • 0022507012 scopus 로고
    • The role of radiotherapy in recurrent and metastatic malignant melanomas: A clinical radiobiological study
    • Overgaard, J. The role of radiotherapy in recurrent and metastatic malignant melanomas: A clinical radiobiological study, Int J Radiat Oncol Biol Phys 12, 867-872, 1986.
    • (1986) Int J Radiat Oncol Biol Phys , vol.12 , pp. 867-872
    • Overgaard, J.1
  • 8
    • 0019964560 scopus 로고
    • Implication of the quadratic cell survival curve and human skin radiation "tolerance dose" on fractionation and superfractionation dose selection
    • Douglas, B. G. Implication of the quadratic cell survival curve and human skin radiation "tolerance dose" on fractionation and superfractionation dose selection, Int J Radiat Oncol Biol Phys 8, 1135-1142, 1982.
    • (1982) Int J Radiat Oncol Biol Phys , vol.8 , pp. 1135-1142
    • Douglas, B.G.1
  • 9
    • 0028332134 scopus 로고
    • 10B-paraboronophenylalanine with special reference to evaluation of radiation dose and damage to the normal skin
    • 10B-paraboronophenylalanine with special reference to evaluation of radiation dose and damage to the normal skin, Radiat Res 138:435-442, 1994.
    • (1994) Radiat Res , vol.138 , pp. 435-442
    • Fukuda, H.1    Hiratsuka, J.2    Honda, C.3
  • 10
    • 0013514373 scopus 로고    scopus 로고
    • BNCT of malignant melanoma - Radiobiological analysis and data comparison with conventional radiotherapy
    • In: Mishima Y, ed.; New York, London: Plenum Press:
    • Fukuda, H., Mishima, Y., Hiratsuka, J, et al. BNCT of malignant melanoma - Radiobiological analysis and data comparison with conventional radiotherapy. In: Mishima Y, ed. Cancer Neutron Capture Therapy, New York, London: Plenum Press: 663-671, 1996
    • (1996) Cancer Neutron Capture Therapy , pp. 663-671
    • Fukuda, H.1    Mishima, Y.2    Hiratsuka, J.3
  • 11
    • 0033070298 scopus 로고    scopus 로고
    • 10B-p-boronophenyl-alanine in tumours, skin and blood of melanoma patients: A study of boron neutron capture therapy for malignant melanoma
    • 10B-p-boronophenyl-alanine in tumours, skin and blood of melanoma patients: A study of boron neutron capture therapy for malignant melanoma, Melanoma Res 9:75-83, 1999.
    • (1999) Melanoma Res , vol.9 , pp. 75-83
    • Fukuda, H.1    Honda, C.2    Wadabayashi, N.3
  • 12
    • 0018072244 scopus 로고
    • The relationship between total dose, number of fractions and fraction size in the response of malignant melanoma in patients
    • Hornsey, S. The relationship between total dose, number of fractions and fraction size in the response of malignant melanoma in patients, Br J Radiol 51:905-909, 1977
    • (1977) Br J Radiol , vol.51 , pp. 905-909
    • Hornsey, S.1
  • 13
    • 0018897594 scopus 로고
    • Radiation therapy of malignant melanoma
    • Overgaard, J. Radiation therapy of malignant melanoma, Int J Radiat Oncol Phys 6:41-44, 1980.
    • (1980) Int J Radiat Oncol Phys , vol.6 , pp. 41-44
    • Overgaard, J.1
  • 14
    • 0022651806 scopus 로고
    • Some factors of importance in the radiation treatment of malignant melanoma
    • Overgaad, J., Overgaard, M., Hansen, P. V., et al. Some factors of importance in the radiation treatment of malignant melanoma, Radiother Oncol 5:183-192, 1986.
    • (1986) Radiother Oncol , vol.5 , pp. 183-192
    • Overgaad, J.1    Overgaard, M.2    Hansen, P.V.3
  • 15
    • 0017056890 scopus 로고
    • Radiation therapy of malignant melanoma: Experience with high individual treatment doses
    • Hebermalz, H. J., Fisher, J. J. Radiation therapy of malignant melanoma: Experience with high individual treatment doses, Cancer 38:2258-2262, 1976.
    • (1976) Cancer , vol.38 , pp. 2258-2262
    • Hebermalz, H.J.1    Fisher, J.J.2
  • 16
    • 0023242989 scopus 로고
    • Malignant melanoma: Analysis of dose fractionation in radiation therapy
    • Konefal, J. B., Emami, B., Pilepich, M. V. Malignant melanoma: Analysis of dose fractionation in radiation therapy, Radiology 164:607-610, 1987.
    • (1987) Radiology , vol.164 , pp. 607-610
    • Konefal, J.B.1    Emami, B.2    Pilepich, M.V.3
  • 17
    • 0021164443 scopus 로고
    • Human malignant melanoma
    • Mackie, R. M., Young, D. Human malignant melanoma, Int J Dermatol 23:433-443, 1984.
    • (1984) Int J Dermatol , vol.23 , pp. 433-443
    • Mackie, R.M.1    Young, D.2
  • 18
    • 0031769698 scopus 로고    scopus 로고
    • Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy
    • Bradley, P. D., Rosenfeld, A. B. Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy, Medical Physics 25:2220-2225, 1998.
    • (1998) Medical Physics , vol.25 , pp. 2220-2225
    • Bradley, P.D.1    Rosenfeld, A.B.2
  • 19
    • 0031917756 scopus 로고    scopus 로고
    • Fluorine-18-labeled fluoroboronophenylalanine PET in patients with glioma
    • Imahori, Y., Ueda, S., Ohmori, Y., et al. Fluorine-18-labeled fluoroboronophenylalanine PET in patients with glioma. J Nucl Med 39:325-333, 1998.
    • (1998) J Nucl Med , vol.39 , pp. 325-333
    • Imahori, Y.1    Ueda, S.2    Ohmori, Y.3
  • 20
    • 0030712915 scopus 로고    scopus 로고
    • Evaluation of fluorine-18-BPA-fructose for boron neutron capture treatment planning
    • Kabalka, G. W., Smith, G. T., Reid, W. S., et al. Evaluation of fluorine-18-BPA-fructose for boron neutron capture treatment planning, J Nucl Med 38: 1762-1767, 1997.
    • (1997) J Nucl Med , vol.38 , pp. 1762-1767
    • Kabalka, G.W.1    Smith, G.T.2    Reid, W.S.3
  • 21
    • 0033795948 scopus 로고    scopus 로고
    • A non-invasive dose estimation system for clinical BNCT based on PG-SPECT - Conceptual study and fundamental experiments using HPGe and CdTe semiconductor detectors
    • Kobayashi, T., Sakurai, Y. and Ichikawa, M. A non-invasive dose estimation system for clinical BNCT based on PG-SPECT - Conceptual study and fundamental experiments using HPGe and CdTe semiconductor detectors, Medical Phys 27:2124-2132, 2000.
    • (2000) Medical Phys , vol.27 , pp. 2124-2132
    • Kobayashi, T.1    Sakurai, Y.2    Ichikawa, M.3