메뉴 건너뛰기




Volumn 50, Issue 6 II, 2003, Pages 2420-2426

Extensive Performance Studies for the ATLAS BIS-MDT Precision Muon Chambers with Cosmic Rays

(27)  Alexopoulos, T a   Avramidou, R a   Bratzler, U a   Cernoch, C b   Dris, M a   Fassouliotis, D c   Filippas, T A a   Fokitis, E a   Gazis, E N a   Ioannou, P c   Katsoufis, E C a   Kourkoumelis, Ch c   Krepouri, A d   Liolios, T d   Maltezos, S a   Manolopoulou, M d   Palestini, S b   Petridou, Ch d   Polychronakos, V e   Sampsonidis, D d   more..


Author keywords

ATLAS; Cosmic rays; Gas detectors; Muon spectrometer; Particle detectors

Indexed keywords

COMPUTER SIMULATION; GAMMA RAYS; GAS DETECTORS; HIGH ENERGY PHYSICS; IRRADIATION; MAGNETS; PARTICLE DETECTORS; PROTONS; SIGNAL THEORY; SPECTROMETERS;

EID: 10744221007     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2003.820630     Document Type: Conference Paper
Times cited : (5)

References (21)
  • 2
    • 0034274088 scopus 로고    scopus 로고
    • A facility for the test of large area muon chambers at high rates: CERN-EP-2000-031, CERN-SL-2000-008-EA, Geneva, CERN, 16 Feb. 2000
    • S. Agosteo et al., "A facility for the test of large area muon chambers at high rates: CERN-EP-2000-031, CERN-SL-2000-008-EA, Geneva, CERN, 16 Feb. 2000," Nucl. Instrum. Methods Phys. Res., vol. A: 452, no. 1-2, pp. 94-104, 2000.
    • (2000) Nucl. Instrum. Methods Phys. Res. , vol.A 452 , Issue.1-2 , pp. 94-104
    • Agosteo, S.1
  • 4
    • 0036475686 scopus 로고    scopus 로고
    • The first precision drift tube chambers for the ATLAS muon spectrometer: ATL-MUON-2001-004, (MPI-PhE/2001-03), (ATL-COM-MUON-2001-015), 28 Feb. 2001
    • F. Bauer et al., "The first precision drift tube chambers for the ATLAS muon spectrometer: ATL-MUON-2001-004, (MPI-PhE/2001-03), (ATL-COM-MUON-2001-015), 28 Feb. 2001," Nucl. Iustrum. Methods, vol. A478, pp. 153-157, 2000.
    • (2000) Nucl. Iustrum. Methods , vol.A478 , pp. 153-157
    • Bauer, F.1
  • 8
    • 0036815730 scopus 로고    scopus 로고
    • A quality assurance and quality control (QA_QC) procedure of the monitored drift tubes (MDT) for the BIS-chambers of the ATLAS muon spectrometer
    • Oct.
    • _, "A quality assurance and quality control (QA_QC) procedure of the monitored drift tubes (MDT) for the BIS-chambers of the ATLAS muon spectrometer," IEEE Trans. Nucl. Sci. - Nucl. Instrum. Methods, vol. 49, no. 5, pp. 2484-2487, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. - Nucl. Instrum. Methods , vol.49 , Issue.5 , pp. 2484-2487
  • 18
    • 17444445347 scopus 로고    scopus 로고
    • Construction and test of a full scale prototype of an atlas muon spectrometer tracking chamber
    • A. Biscossa et al., "Construction and test of a full scale prototype of an atlas muon spectrometer tracking chamber," Nucl. Instrum. Methods, vol. A425, pp. 140-164, 1999.
    • (1999) Nucl. Instrum. Methods , vol.A425 , pp. 140-164
    • Biscossa, A.1
  • 19
    • 0347571801 scopus 로고    scopus 로고
    • Calypso: A full scale MDT prototype for the ATLAS muon spectrometer
    • _, "Calypso: A full scale MDT prototype for the ATLAS muon spectrometer," Nucl. Instrum. Methods, vol. A419, pp. 331-335, 1998.
    • (1998) Nucl. Instrum. Methods , vol.A419 , pp. 331-335
  • 21
    • 0035306404 scopus 로고    scopus 로고
    • Construction and test of MDT chambers for the ATLAS muon spectrometer
    • F. Bauer et al., "Construction and test of MDT chambers for the ATLAS muon spectrometer," Nucl. Instrum. Methods Phys. Res., vol. A: 46, pp. 17-20, 2000.
    • (2000) Nucl. Instrum. Methods Phys. Res. , vol.A 46 , pp. 17-20
    • Bauer, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.