메뉴 건너뛰기




Volumn 49 II, Issue 5, 2002, Pages 2484-2487

A quality assurance and quality control (QA_QC) procedure of the monitored drift tubes (MDT) for the BIS-chambers of the ATLAS muon spectrometer

Author keywords

ATLAS; Gas detectors; Muon spectrometer; Particle detectors; Quality control

Indexed keywords

COLLIDING BEAM ACCELERATORS; ELECTRIC CURRENT MEASUREMENT; PARTICLE SPECTROMETERS; PROTONS; QUALITY ASSURANCE; QUALITY CONTROL; TENSILE TESTING;

EID: 0036815730     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2002.803885     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 0011951605 scopus 로고    scopus 로고
    • ATLAS muon spectrometer tech. design rep
    • "ATLAS Muon Spectrometer Tech. Design Rep.," ATLAS Collab., CERN/LHCC/97-22, vol. TDR 10, 1997.
    • (1997) ATLAS Collab., CERN/LHCC/97-22 , vol.TDR10
  • 3
    • 0011991716 scopus 로고    scopus 로고
    • The QA_QC results of the BIS-module-0 monitored drift tubes
    • ATL-MUON-NOTE-2000-019
    • M. Dris, E. N. Gazis, S. Maltezos, G. Stavropoulos, and R. Avramidou, "The QA_QC Results of the BIS-Module-0 Monitored Drift Tubes,", ATL-MUON-NOTE-2000-019, 1999.
    • (1999)
    • Dris, M.1    Gazis, E.N.2    Maltezos, S.3    Stavropoulos, G.4    Avramidou, R.5
  • 4
    • 0004310102 scopus 로고    scopus 로고
    • Construction of the BIS MDT chamber module-0
    • ATL-COM-MUON-NOTE-2001-006
    • D. Sampsonidis et al., "Construction of the BIS MDT Chamber Module-0,", ATL-COM-MUON-NOTE-2001-006, 2001.
    • (2001)
    • Sampsonidis, D.1
  • 5
    • 0034204838 scopus 로고    scopus 로고
    • An electromagnetic micrometer to measure the wire centering in high-resolution aluminum drift tubes
    • June
    • M. Cambiaghi et al., "An electromagnetic micrometer to measure the wire centering in high-resolution Aluminum drift tubes," IEEE Trans. Nucl. Sci., vol. 47, pp. 784-788, June 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 784-788
    • Cambiaghi, M.1
  • 6
    • 0035304902 scopus 로고    scopus 로고
    • The pavia-roma 1 ATLAS MDT quality control system
    • C. Bini et al., "The Pavia-Roma 1 ATLAS MDT quality control system," Nucl. Instr. Meth., vol. A461, pp. 65-67, 2001.
    • (2001) Nucl. Instr. Meth. , vol.A461 , pp. 65-67
    • Bini, C.1
  • 7
    • 1642327869 scopus 로고    scopus 로고
    • Differential manometer for gas leak measurement
    • [On-line]
    • G. Chelkov. Differential Manometer for Gas Leak Measurement. [On-line]. Available http://atlas.web.cern.ch/Atlas/project/MDT/www/mirrordubna/atlas/QAQC/chleak/dfm anom.htm
    • Chelkov, G.1
  • 8
    • 4243460889 scopus 로고    scopus 로고
    • The quality assurance_quality control of the monitored drift tubes
    • Nat. Tech. Univ. Athens, HEP Lab., ATL-MUON-NOTE 2001-017
    • T. Alexopoulos et al., "The Quality Assurance_Quality Control of the Monitored Drift Tubes," Nat. Tech. Univ. Athens, HEP Lab., ATL-MUON-NOTE 2001-017, 2001.
    • (2001)
    • Alexopoulos, T.1
  • 9
    • 0011921029 scopus 로고    scopus 로고
    • Gas leak rate measurement system for the LHC-ATLAS BIS-monitored drift tubes
    • T. Alexopoulos et al., "Gas Leak Rate Measurement System for the LHC-ATLAS BIS-Monitored Drift Tubes,", SCIENTIFIC-NOTE-ATLAS 2002-016, 2001.
    • (2001) SCIENTIFIC-NOTE-ATLAS 2002-016
    • Alexopoulos, T.1
  • 10
    • 0004349448 scopus 로고    scopus 로고
    • Local monitor box (LMB) for the ATLAS-DCS
    • [On-line]
    • H. Burckhart. Local Monitor Box (LMB) for the ATLAS-DCS. [On-line]. Available http://atlasinfo.cern.ch/ATLAS/GROUPS/DAQTRIG/DCS/lmb.html
    • Burckhart, H.1
  • 11
    • 0004342156 scopus 로고    scopus 로고
    • A low cost accurate system for multi-point temperature measurement and processing
    • ATL-NOTE, to be published
    • T. Alexopoulos et al., "A Low Cost Accurate System for Multi-Point Temperature Measurement and Processing,", ATL-NOTE, to be published.
    • Alexopoulos, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.