Analysis and evaluation of periodic physiological organ motion in radiotherapy treatments

Author keywords

Clinical target volume; Fluoroscopic images; Margins; Organ motion; Radiotherapy

Indexed keywords

ARTICLE; AUTOMATION; COMPUTER ASSISTED RADIOTHERAPY; DENSITY FUNCTIONAL THEORY; FLUOROSCOPY; MOVEMENT (PHYSIOLOGY); ORGAN; PERIODICITY; PRIORITY JOURNAL; PROBABILITY; TREATMENT PLANNING;

EID: 10044261068     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2004.08.023     Document Type: Article
Times cited : (8)

References (20)
  • 3
    • 0033237778 scopus 로고    scopus 로고
    • Set-up error and organ motion uncertainty: A review
    • J.T. Booth, and S.F. Zavgorodni Set-up error and organ motion uncertainty: a review Australas Phys Eng Sci Med 22 1999 29 47
    • (1999) Australas Phys Eng Sci Med , vol.22 , pp. 29-47
    • Booth, J.T.1    Zavgorodni, S.F.2
  • 4
    • 10044255096 scopus 로고    scopus 로고
    • CTV definition by automatic measurement and integration of organ motion. 19th annual ESTRO meeting. Estambul 2000
    • S. Díez, A. Santos, and J. Garcia CTV definition by automatic measurement and integration of organ motion. 19th annual ESTRO meeting. Estambul 2000 Radiother Oncol 56 2000 61
    • (2000) Radiother Oncol , vol.56 , pp. 61
    • Díez, S.1    Santos, A.2    Garcia, J.3
  • 7
    • 0031870905 scopus 로고    scopus 로고
    • What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
    • L. Ekberg, O. Holmberg, L. Wittgren, G. Bjelkengren, and T. Landberg What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? Radiother Oncol 48 1998 71 77
    • (1998) Radiother Oncol , vol.48 , pp. 71-77
    • Ekberg, L.1    Holmberg, O.2    Wittgren, L.3    Bjelkengren, G.4    Landberg, T.5
  • 10
    • 0003651542 scopus 로고
    • Prescribing, recording and reporting photon beam therapy
    • ICRU;
    • International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy. ICRU Report 50. ICRU; 1993.
    • (1993) ICRU Report 50
  • 11
    • 0003418877 scopus 로고    scopus 로고
    • Prescribing, recording and reporting photon beam therapy. (Supplement to ICRU report 50)
    • ICRU;
    • International Commission on Radiation Units and Measurements. Prescribing, recording and reporting photon beam therapy. (Supplement to ICRU report 50). ICRU Report 62. ICRU; 1999.
    • (1999) ICRU Report 62
  • 12
    • 0034006554 scopus 로고    scopus 로고
    • Breathing-synchronized radiotherapy program at the University of California Davis Center Cancer
    • H.D. Kubo, P.M. Len, S. Minohara, and H. Mostafavi Breathing-synchronized radiotherapy program at the University of California Davis Center Cancer Med Phys 27 2000 343 353
    • (2000) Med Phys , vol.27 , pp. 343-353
    • Kubo, H.D.1    Len, P.M.2    Minohara, S.3    Mostafavi, H.4
  • 13
    • 0032941481 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculations
    • A.E. Lujan, E.W. Larsen, J.M. Balter, and R.K. Ten Haken A method for incorporating organ motion due to breathing into 3D dose calculations Med Phys 26 1999 715 720
    • (1999) Med Phys , vol.26 , pp. 715-720
    • Lujan, A.E.1    Larsen, E.W.2    Balter, J.M.3    Ten Haken, R.K.4
  • 14
    • 0029975378 scopus 로고    scopus 로고
    • A method for incorporating organ motion uncertainties into three-dimensional conformal treatment plans
    • G.S. Mageras, G.J. Kutcher, and S.A. Leibel A method for incorporating organ motion uncertainties into three-dimensional conformal treatment plans Int J Radiant Oncol Biol Phys 35 1996 333 342
    • (1996) Int J Radiant Oncol Biol Phys , vol.35 , pp. 333-342
    • Mageras, G.S.1    Kutcher, G.J.2    Leibel, S.A.3
  • 15
    • 0034128896 scopus 로고    scopus 로고
    • Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variation into the radiotherapy treatment planning system
    • S.D. McCarter, and W.A. Beckhan Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variation into the radiotherapy treatment planning system Phys Med Biol 45 2000 923 931
    • (2000) Phys Med Biol , vol.45 , pp. 923-931
    • McCarter, S.D.1    Beckhan, W.A.2
  • 16
    • 0033813993 scopus 로고    scopus 로고
    • How should breathing motion be combined with other errors when drawing margins around clinical target volumes?
    • A.L. McKenzie How should breathing motion be combined with other errors when drawing margins around clinical target volumes? Br J Radiol 73 2000 973 977
    • (2000) Br J Radiol , vol.73 , pp. 973-977
    • McKenzie, A.L.1
  • 17
    • 0028289096 scopus 로고
    • Predictive respiratory gating: A new method to reduce motion artifacts on CT scans
    • C.J. Ritchie, J. Hsieh, M.F. Gard, J.D. Godwin, Y. Kim, and C.R. Crawford Predictive respiratory gating: a new method to reduce motion artifacts on CT scans Radiology 190 1994 847 852
    • (1994) Radiology , vol.190 , pp. 847-852
    • Ritchie, C.J.1    Hsieh, J.2    Gard, M.F.3    Godwin, J.D.4    Kim, Y.5    Crawford, C.R.6
  • 18
    • 0007261749 scopus 로고    scopus 로고
    • Characterization of respiratory motion for paediatric conformal 3D therapy
    • M.R. Sontag, Z.W. Lai, B.W. Mcroy, and R.D. Waters Characterization of respiratory motion for paediatric conformal 3D therapy Med Phys 23 1996
    • (1996) Med Phys , vol.23
    • Sontag, M.R.1    Lai, Z.W.2    McRoy, B.W.3    Waters, R.D.4
  • 20
    • 0033013520 scopus 로고    scopus 로고
    • The use of active breathing control (ABC) to reduce margin for breathing motion
    • J.W. Wong, M.B. Sharpe, and D.A. Jaffray The use of active breathing control (ABC) to reduce margin for breathing motion Int J Radiat Oncol Biol Phys 44 1999 911 919
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , pp. 911-919
    • Wong, J.W.1    Sharpe, M.B.2    Jaffray, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.