메뉴 건너뛰기




Volumn 36, Issue 2, 2004, Pages 197-199

Microfluidic Tools for High-Throughput Screening

Author keywords

[No Author keywords available]

Indexed keywords

DIMETICONE; GLASS; SILICONE; WATER OIL CREAM;

EID: 0842288281     PISSN: 07366205     EISSN: None     Source Type: Journal    
DOI: 10.2144/04362te01     Document Type: Short Survey
Times cited : (22)

References (19)
  • 1
    • 0036532590 scopus 로고    scopus 로고
    • Novel miniaturized systems in high-throughput screening
    • Battersby, B.J. and M. Trau. 2002. Novel miniaturized systems in high-throughput screening. Trends Biotechnol. 20:167-173.
    • (2002) Trends Biotechnol. , vol.20 , pp. 167-173
    • Battersby, B.J.1    Trau, M.2
  • 2
  • 5
    • 0032225683 scopus 로고    scopus 로고
    • A microfabricated device for sizing DNA and sorting cells
    • Chou, H.-P., C. Spence, A. Scherer, and S. Quake. 1998. A microfabricated device for sizing DNA and sorting cells. Proc. SPIE 3258:181.
    • (1998) Proc. SPIE , vol.3258 , pp. 181
    • Chou, H.-P.1    Spence, C.2    Scherer, A.3    Quake, S.4
  • 7
    • 0023335467 scopus 로고
    • Spontaneous vesiculation of uncharged phospholipid dispersions consisting of lecithin and lysolecithin
    • Hauser, H. 1987. Spontaneous vesiculation of uncharged phospholipid dispersions consisting of lecithin and lysolecithin. Chem. Phys. Lipids 43:283-299.
    • (1987) Chem. Phys. Lipids , vol.43 , pp. 283-299
    • Hauser, H.1
  • 8
    • 0031854986 scopus 로고    scopus 로고
    • Man-made cell-like compartments for molecular evolution
    • Tawfik, D.S. and A.D. Griffiths. 1998. Man-made cell-like compartments for molecular evolution. Nat. Biotechnol. 16:652-656.
    • (1998) Nat. Biotechnol. , vol.16 , pp. 652-656
    • Tawfik, D.S.1    Griffiths, A.D.2
  • 9
    • 4544366400 scopus 로고    scopus 로고
    • Dynamic pattern formation in a vesicle-generating microfluidic device
    • Thorsen, T., R.W. Roberts, F.H. Arnold, and S.R. Quake. 2001. Dynamic pattern formation in a vesicle-generating microfluidic device. Phys. Rev. Lett. 86:4163-4166.
    • (2001) Phys. Rev. Lett. , vol.86 , pp. 4163-4166
    • Thorsen, T.1    Roberts, R.W.2    Arnold, F.H.3    Quake, S.R.4
  • 10
    • 0037450165 scopus 로고    scopus 로고
    • Ismagilov. A microfluidic systems for controlling reaction networks in time
    • Song, H., J.D. Tice, and R.F. 2003. Ismagilov. A microfluidic systems for controlling reaction networks in time. Angew. Chem. Intl. Ed. 42: 768-772.
    • (2003) Angew. Chem. Intl. Ed. , vol.42 , pp. 768-772
    • Song, H.1    Tice, J.D.2
  • 12
    • 0035456648 scopus 로고    scopus 로고
    • Cell placement and neural guidance using a three-dimensional microfluidic array
    • Griscom, L., P. Degenaar, B. LePioufle, E. Tamiya, and H. Fujita. 2001. Cell placement and neural guidance using a three-dimensional microfluidic array. Jpn. J. Appl. Physics 40:5485-5490.
    • (2001) Jpn. J. Appl. Physics , vol.40 , pp. 5485-5490
    • Griscom, L.1    Degenaar, P.2    LePioufle, B.3    Tamiya, E.4    Fujita, H.5
  • 14
    • 0344496517 scopus 로고    scopus 로고
    • Patterning ligands on reactive SAMs by microcontact printing
    • Lahiri, J., E. Ostuni, and G.M. Whitesides. 1999. Patterning ligands on reactive SAMs by microcontact printing. Langmuir 15:2055-2060.
    • (1999) Langmuir , vol.15 , pp. 2055-2060
    • Lahiri, J.1    Ostuni, E.2    Whitesides, G.M.3
  • 16
    • 0034615958 scopus 로고    scopus 로고
    • Monolithic microfabricated valves and pumps by multilayer soft lithography
    • Unger, M.A., H.-P. Chou, T. Thorsen, A. Scherer, and S. Quake. 2000. Monolithic microfabricated valves and pumps by multilayer soft lithography. Science 288:113-116.
    • (2000) Science , vol.288 , pp. 113-116
    • Unger, M.A.1    Chou, H.-P.2    Thorsen, T.3    Scherer, A.4    Quake, S.5
  • 17
    • 0037131390 scopus 로고    scopus 로고
    • Microfluidic large-scale integration
    • Thorsen, T., S.J. Maerkl, and S.R. Quake. 2002. Microfluidic large-scale integration. Science 298:580-584.
    • (2002) Science , vol.298 , pp. 580-584
    • Thorsen, T.1    Maerkl, S.J.2    Quake, S.R.3
  • 18
    • 0036603767 scopus 로고    scopus 로고
    • Microchip-based high-throughput screening analysis of combinatorial libraries
    • Khandurina, J. and Andras Guttman. 2002. Microchip-based high-throughput screening analysis of combinatorial libraries. Curr. Opin. Chem. Biol. 6:359-366.
    • (2002) Curr. Opin. Chem. Biol. , vol.6 , pp. 359-366
    • Khandurina, J.1    Guttman, A.2
  • 19
    • 18244421009 scopus 로고    scopus 로고
    • Making analysis in the life sciences faster through miniaturization
    • Sassi, A.P., Q.F. Xue, and H.H. Hooper. 2000. Making analysis in the life sciences faster through miniaturization. Am. Lab. 32:36-41.
    • (2000) Am. Lab. , vol.32 , pp. 36-41
    • Sassi, A.P.1    Xue, Q.F.2    Hooper, H.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.