메뉴 건너뛰기




Volumn 10, Issue 4, 1996, Pages 514-516

A comparison of slit-lamp supported versus hand-held biometry

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BIOMETRY; CATARACT EXTRACTION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EYE REFRACTION; HUMAN; INTERMETHOD COMPARISON; LENS IMPLANT; RANDOMIZED CONTROLLED TRIAL;

EID: 0029818844     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/eye.1996.112     Document Type: Article
Times cited : (3)

References (10)
  • 3
    • 0023105263 scopus 로고
    • Theoretical approach to intraocular lens calculation using Gaussian optics
    • Olsen T. Theoretical approach to intraocular lens calculation using Gaussian optics. J Cataract Refract Surg 1987;13:141-5.
    • (1987) J Cataract Refract Surg , vol.13 , pp. 141-145
    • Olsen, T.1
  • 4
    • 0016713554 scopus 로고
    • Calculation of the optical power of intraocular lenses
    • Fyodorov SN, Galin MA, Linksa A. Calculation of the optical power of intraocular lenses. Invest Ophthalmol 1975;14:625-8.
    • (1975) Invest Ophthalmol , vol.14 , pp. 625-628
    • Fyodorov, S.N.1    Galin, M.A.2    Linksa, A.3
  • 5
    • 0025056799 scopus 로고
    • Effect of keratometer and axial length measurement errors on primary implant power calculations
    • McEwan JR, Massengill RK, Samuel D, et al. Effect of keratometer and axial length measurement errors on primary implant power calculations. J Cataract Refract Surg 1990;16:61-70.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 61-70
    • McEwan, J.R.1    Massengill, R.K.2    Samuel, D.3
  • 6
    • 0020263309 scopus 로고
    • Axial length measurement and its relation to intraocular lens power calculations
    • Shammas HJF. Axial length measurement and its relation to intraocular lens power calculations. Am Intra-Ocular Implant Soc J 1982;8:346-9.
    • (1982) Am Intra-Ocular Implant Soc J , vol.8 , pp. 346-349
    • Shammas, H.J.F.1
  • 7
    • 0023811024 scopus 로고
    • Calculating axial length in the aphakic and pseudophakic eye
    • Olsen T. Calculating axial length in the aphakic and pseudophakic eye. J Cataract Refract Surg 1988;15: 413-6.
    • (1988) J Cataract Refract Surg , vol.15 , pp. 413-416
    • Olsen, T.1
  • 8
    • 0022449921 scopus 로고
    • Improving the predictability of intraocular lens power calculations
    • Holladay JT, Prager TC, Ruiz RS, et al. Improving the predictability of intraocular lens power calculations. Arch Ophthalmol 1986;104:539-41.
    • (1986) Arch Ophthalmol , vol.104 , pp. 539-541
    • Holladay, J.T.1    Prager, T.C.2    Ruiz, R.S.3
  • 9
    • 0024315421 scopus 로고
    • Comparison of contact and immersion techniques for axial length measurement and implant power calculation
    • Schelenz J, Kammann J. Comparison of contact and immersion techniques for axial length measurement and implant power calculation. J Cataract Refract Surg 1989;15:425-8.
    • (1989) J Cataract Refract Surg , vol.15 , pp. 425-428
    • Schelenz, J.1    Kammann, J.2
  • 10
    • 0025174236 scopus 로고
    • Clinical evaluation of the Bio-pen for axial length measurement
    • Shammas JH, Swearingen M. Clinical evaluation of the Bio-pen for axial length measurement. J Cataract Refract Surg 1990;16:120-2.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 120-122
    • Shammas, J.H.1    Swearingen, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.