-
1
-
-
0024798039
-
In-vitro spinal arthrodesis implant mechanical testing protocols
-
Ashman, R. B.; J. E. Bechtold, W. T. Edwards: In-vitro spinal arthrodesis implant mechanical testing protocols. J. Spinal Disord. 2 (1989) 274-281.
-
(1989)
J. Spinal Disord.
, vol.2
, pp. 274-281
-
-
Ashman, R.B.1
Bechtold, J.E.2
Edwards, W.T.3
-
2
-
-
0032169008
-
A biomechanical study of anterior thoracolumbar screw fixation
-
Breeze, S. W.; B. J. Doherty, P. S. Noble, A. LeBlanc, M. H. Heggeness: A biomechanical study of anterior thoracolumbar screw fixation. Spine 23 (1998) 1829-1831.
-
(1998)
Spine
, vol.23
, pp. 1829-1831
-
-
Breeze, S.W.1
Doherty, B.J.2
Noble, P.S.3
LeBlanc, A.4
Heggeness, M.H.5
-
3
-
-
0030898188
-
Operative treatment of scoliosis with Cotrel-Dubousset-Hopf instrumentation. New anterior spinal device
-
Hopf, C. G.; P. Eysel, J. Dubousset: Operative treatment of scoliosis with Cotrel-Dubousset-Hopf instrumentation. New anterior spinal device. Spine 22 (1997) 618-628.
-
(1997)
Spine
, vol.22
, pp. 618-628
-
-
Hopf, C.G.1
Eysel, P.2
Dubousset, J.3
-
4
-
-
0030024429
-
Strength of fixation of anterior vertebral body screws
-
Horton, W. C.; S. F. Blackstock, J. T. Norman, C. S. Hill, M. A. Feiertag, W. C. Hutton: Strength of fixation of anterior vertebral body screws. Spine 21 (1996), 439-444.
-
(1996)
Spine
, vol.21
, pp. 439-444
-
-
Horton, W.C.1
Blackstock, S.F.2
Norman, J.T.3
Hill, C.S.4
Feiertag, M.A.5
Hutton, W.C.6
-
5
-
-
0345726022
-
Changes in cadaveric cancellous vertebral bone strength in relation to time. A biomechanical investigation
-
Käâb, M.J.; R. Putz, D. Gebauer, W. Plitz: Changes in cadaveric cancellous vertebral bone strength in relation to time. A biomechanical investigation. Spine 23 (1998) 1215-1219.
-
(1998)
Spine
, vol.23
, pp. 1215-1219
-
-
Käâb, M.J.1
Putz, R.2
Gebauer, D.3
Plitz, W.4
-
6
-
-
0029977364
-
New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis. Application of the Kaneda two-rod system
-
Kaneda, K.; Y. Shono, S. Satoh, K. Abumi: New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis. Application of the Kaneda two-rod system. Spine 21 (1996) 1250-62.
-
(1996)
Spine
, vol.21
, pp. 1250-1262
-
-
Kaneda, K.1
Shono, Y.2
Satoh, S.3
Abumi, K.4
-
7
-
-
0029999312
-
Langfristige Behandlungs-ergebnisse ventraler und kombinierter ventrodorsaler Spondylodesen in der operativen Therapie der Skoliose
-
Karbowski, A.; U. Liljenqvist, D. Bettin, J. Heine: Langfristige Behandlungs-ergebnisse ventraler und kombinierter ventrodorsaler Spondylodesen in der operativen Therapie der Skoliose. Z Orthop 134 (1996) 81-88.
-
(1996)
Z. Orthop.
, vol.134
, pp. 81-88
-
-
Karbowski, A.1
Liljenqvist, U.2
Bettin, D.3
Heine, J.4
-
9
-
-
0029825385
-
Insertional torque and pull-out strength of conical and cylindrical pedicle screws in cadaveric bone
-
Kwok, A. W. L.; J. A. Finkelstein, T. Woodside, T. C. Hearn, R. W. Hu: Insertional torque and pull-out strength of conical and cylindrical pedicle screws in cadaveric bone. Spine 21 (1996) 2429-2434.
-
(1996)
Spine
, vol.21
, pp. 2429-2434
-
-
Kwok, A.W.L.1
Finkelstein, J.A.2
Woodside, T.3
Hearn, T.C.4
Hu, R.W.5
-
10
-
-
0032522914
-
Anterior vertebral body screw pullout testing. A comparison of Zielke VDS, Kaneda, Universal Spine System and Universal Spine System with pullout-resistant nut
-
Lieberman, I. H.; R. Khazim, T. Woodside: Anterior vertebral body screw pullout testing. A comparison of Zielke VDS, Kaneda, Universal Spine System and Universal Spine System with pullout-resistant nut. Spine 23 (1998) 908-910.
-
(1998)
Spine
, vol.23
, pp. 908-910
-
-
Lieberman, I.H.1
Khazim, R.2
Woodside, T.3
-
12
-
-
0036940380
-
Die MACS TL HMA Hohltonne. Eine alternative Möglichkeit der stabilen Implantatverankerung im Wirbelkörper auch für langstreckige Fusionen
-
Schramm M.; S. Krummbein, H. Kraus, H. Hirschfelder, R. P. Pitto: Die MACS TL HMA Hohltonne. Eine alternative Möglichkeit der stabilen Implantatverankerung im Wirbelkörper auch für langstreckige Fusionen. Der Orthopäde 31 (2002) 494-502.
-
(2002)
Der Orthopäde
, vol.31
, pp. 494-502
-
-
Schramm, M.1
Krummbein, S.2
Kraus, H.3
Hirschfelder, H.4
Pitto, R.P.5
-
13
-
-
0026046073
-
A biomechanical analysis of Zielke, Kaneda and Cotrel-Dubousset instrumentations in thoracolumbar scoliosis. A calf spine model
-
Shono, Y.; K. Kaneda, I. Yamamota: A biomechanical analysis of Zielke, Kaneda and Cotrel-Dubousset instrumentations in thoracolumbar scoliosis. A calf spine model. Spine 16 (1991) 1305-1311.
-
(1991)
Spine
, vol.16
, pp. 1305-1311
-
-
Shono, Y.1
Kaneda, K.2
Yamamota, I.3
-
14
-
-
0025351033
-
Experimental testing and comparison of variables in transpedicular screw fixation. A biomechanical study
-
Skinner, R.; J. Maybee, E. Transfeldt, R. Venter, W. Chalmers: Experimental testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 16, (1990) 195-201.
-
(1990)
Spine
, vol.16
, pp. 195-201
-
-
Skinner, R.1
Maybee, J.2
Transfeldt, E.3
Venter, R.4
Chalmers, W.5
-
15
-
-
0015694102
-
Mechanical factors influencing the holding power of screws in compact bone
-
Uhthoff, H. K.: Mechanical factors influencing the holding power of screws in compact bone. J. Bone Joint Surg., 55-B (1973) 633-639.
-
(1973)
J. Bone Joint Surg.
, vol.55 B
, pp. 633-639
-
-
Uhthoff, H.K.1
-
16
-
-
0030152272
-
Biomechanical comparison of calf and human spines
-
Wilke, H. J.; S. Krischak, L. Claes: Biomechanical comparison of calf and human spines. J. Orthop. Research 14 (1996) 500-503.
-
(1996)
J. Orthop. Research
, vol.14
, pp. 500-503
-
-
Wilke, H.J.1
Krischak, S.2
Claes, L.3
-
17
-
-
0031924426
-
Testing criteria for spinal implants - Recommendations for the standardization of in vitro stability testing of spinal implants
-
Wilke, H. J.; K. Wenger, L. Claes: Testing criteria for spinal implants - recommendations for the standardization of in vitro stability testing of spinal implants. Eur. Spine J. 7 (1998) 148-154.
-
(1998)
Eur. Spine J.
, vol.7
, pp. 148-154
-
-
Wilke, H.J.1
Wenger, K.2
Claes, L.3
-
18
-
-
0034992658
-
Combined antero-posterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure
-
Wilke, H.J.; V. Kemmerich, L. E. Claes, M. Arand: Combined antero-posterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure. J. Bone Joint Surg. 83-B (2001) 609-617.
-
(2001)
J. Bone Joint Surg.
, vol.83 B
, pp. 609-617
-
-
Wilke, H.J.1
Kemmerich, V.2
Claes, L.E.3
Arand, M.4
-
19
-
-
0027203876
-
Pedicle screw pullout strength. Correlation with insertional torque
-
Zdeblick, T. A.; D. N. Kunz, M. E. Cooks, R. McCabe: Pedicle screw pullout strength. Correlation with insertional torque. Spine 18 (1993) 1673-1676.
-
(1993)
Spine
, vol.18
, pp. 1673-1676
-
-
Zdeblick, T.A.1
Kunz, D.N.2
Cooks, M.E.3
McCabe, R.4
-
20
-
-
0030052703
-
Performance of ventral spondylodesis screws in cervical vertebrae of varying bone mineral density
-
Zink, P. M.: Performance of ventral spondylodesis screws in cervical vertebrae of varying bone mineral density. Spine (1996) 2145-2152.
-
(1996)
Spine
, pp. 2145-2152
-
-
Zink, P.M.1
|