메뉴 건너뛰기




Volumn 13, Issue 1, 2003, Pages 65-68

Laparoscopic salpingectomy: The definitive treatment for peritoneal dialysis catheter outflow obstruction caused by oviductal fimbriae

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CATHETER OUTFLOW OBSTRUCTION; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; FEMALE; HUMAN; KIDNEY FAILURE; LAPAROSCOPIC SURGERY; LAPAROSCOPY; OBSTRUCTION; OVIDUCT; PERITONEAL CATHETER; PRIORITY JOURNAL; SALPINGECTOMY; SURGICAL TECHNIQUE; TREATMENT INDICATION;

EID: 0347927338     PISSN: 10926429     EISSN: None     Source Type: Journal    
DOI: 10.1089/109264203321235511     Document Type: Article
Times cited : (15)

References (16)
  • 2
    • 0029302696 scopus 로고
    • Laparoscopic salvage of Tenckhoff catheters
    • Owens LV, Brader AH. Laparoscopic salvage of Tenckhoff catheters. Surg Endosc 1995;9:517-518.
    • (1995) Surg Endosc , vol.9 , pp. 517-518
    • Owens, L.V.1    Brader, A.H.2
  • 3
    • 0031085592 scopus 로고    scopus 로고
    • Laparoscopic salvage of malfunctioning peritoneal catheters
    • Amerling R, Maele V, Spivak H, et al. Laparoscopic salvage of malfunctioning peritoneal catheters. Surg Endosc 1997;11:249-259.
    • (1997) Surg Endosc , vol.11 , pp. 249-259
    • Amerling, R.1    Maele, V.2    Spivak, H.3
  • 4
    • 0026212321 scopus 로고
    • Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters
    • Kittur DS, Gazaway PM, Abidin MR. Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters. Surg Laparosc Endosc 1991;1:179-182.
    • (1991) Surg Laparosc Endosc , vol.1 , pp. 179-182
    • Kittur, D.S.1    Gazaway, P.M.2    Abidin, M.R.3
  • 5
    • 0028509552 scopus 로고
    • Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter
    • Hughes CR, Angotti DM, Jubelirer RA. Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter. Surg Endosc 1994;8:1108-1109.
    • (1994) Surg Endosc , vol.8 , pp. 1108-1109
    • Hughes, C.R.1    Angotti, D.M.2    Jubelirer, R.A.3
  • 6
    • 0028913339 scopus 로고
    • Laparoscopic manipulation of a malfunctioning peritoneal dialysis catheter in a child
    • Graham SM, Flowers JL, Fritz K, Voigt R. Laparoscopic manipulation of a malfunctioning peritoneal dialysis catheter in a child. Surg Laparosc Endosc 1995;5:144-147.
    • (1995) Surg Laparosc Endosc , vol.5 , pp. 144-147
    • Graham, S.M.1    Flowers, J.L.2    Fritz, K.3    Voigt, R.4
  • 7
    • 0029918559 scopus 로고    scopus 로고
    • Entrapment of the appendix and the fallopian tube in peritoneal dialysis catheters in two children
    • Borghol M, Alrabeeah A. Entrapment of the appendix and the fallopian tube in peritoneal dialysis catheters in two children. J Pediatr Surg 1996;31:427-429.
    • (1996) J Pediatr Surg , vol.31 , pp. 427-429
    • Borghol, M.1    Alrabeeah, A.2
  • 8
    • 0025066709 scopus 로고
    • Peritoneal dialysis outflow obstruction due to oviductal fimbriae: A case report
    • Abidin MR, Spector DA, Kittur DS. Peritoneal dialysis outflow obstruction due to oviductal fimbriae: A case report. Am J Kidney Dis 1990;3:256-258.
    • (1990) Am J Kidney Dis , vol.3 , pp. 256-258
    • Abidin, M.R.1    Spector, D.A.2    Kittur, D.S.3
  • 9
    • 0024192407 scopus 로고
    • Fallopian tube capture of peritoneal dialysis catheter
    • Harrison NA, Howell GP, Rainford DJ. Fallopian tube capture of peritoneal dialysis catheter. Nephron 1988;50:258.
    • (1988) Nephron , vol.50 , pp. 258
    • Harrison, N.A.1    Howell, G.P.2    Rainford, D.J.3
  • 10
    • 0030163231 scopus 로고    scopus 로고
    • Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two puncture technique
    • Nijhuis PHA, Smulders JF, Jakimowicz JJ. Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two puncture technique. Surg Endosc 1996;10:676-679.
    • (1996) Surg Endosc , vol.10 , pp. 676-679
    • Nijhuis, P.H.A.1    Smulders, J.F.2    Jakimowicz, J.J.3
  • 11
    • 0030330060 scopus 로고    scopus 로고
    • Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters
    • Brandt CP, Ricanati ES. Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters. Adv Perit Dial 1996;12:223-226.
    • (1996) Adv Perit Dial , vol.12 , pp. 223-226
    • Brandt, C.P.1    Ricanati, E.S.2
  • 12
    • 0033023283 scopus 로고    scopus 로고
    • Laparoscopic omentectomy for peritoneal dialysis catheter flow obstruction: A case report and review of the literature
    • Crabtree JH, Fishman A. Laparoscopic omentectomy for peritoneal dialysis catheter flow obstruction: A case report and review of the literature. Surg Laparosc Endosc Percutan Tech 1999;9:228-233.
    • (1999) Surg Laparosc Endosc Percutan Tech , vol.9 , pp. 228-233
    • Crabtree, J.H.1    Fishman, A.2
  • 13
    • 0026568239 scopus 로고
    • Peritoneal dialysis catheter obstruction by fallopian tube: A case report
    • Abouljoud MS, Cruz C, Dow RW, Mozes MF. Peritoneal dialysis catheter obstruction by fallopian tube: A case report. Perit Dial Int 1992;12:257-258.
    • (1992) Perit Dial Int , vol.12 , pp. 257-258
    • Abouljoud, M.S.1    Cruz, C.2    Dow, R.W.3    Mozes, M.F.4
  • 14
    • 0042913293 scopus 로고    scopus 로고
    • Laparoscopic salvage of malfunctioning peritoneal dialysis catheters by ovarian fimbria: A case report
    • Uchiyama K, Fujikawa K, Suga A, Naito K. Laparoscopic salvage of malfunctioning peritoneal dialysis catheters by ovarian fimbria: A case report [in Japanese]. Hinyokika Kiyo 2001;47:669-671.
    • (2001) Hinyokika Kiyo , vol.47 , pp. 669-671
    • Uchiyama, K.1    Fujikawa, K.2    Suga, A.3    Naito, K.4
  • 15
    • 0029179483 scopus 로고
    • Vaginal peritoneal dialysate leakage per fallopian tubes
    • Whiting MA, Smith NI, Agar JW. Vaginal peritoneal dialysate leakage per fallopian tubes. Perit Dial Int 1995;15:85.
    • (1995) Perit Dial Int , vol.15 , pp. 85
    • Whiting, M.A.1    Smith, N.I.2    Agar, J.W.3
  • 16
    • 0027416801 scopus 로고
    • Fallopian tube capture of chronic peritoneal dialysis catheter
    • Macallister RJ, Morgan SH. Fallopian tube capture of chronic peritoneal dialysis catheter. Perit Dial Int 1993;13:74-76.
    • (1993) Perit Dial Int , vol.13 , pp. 74-76
    • Macallister, R.J.1    Morgan, S.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.