Volumn 9, Issue 3, 1999, Pages 228-233

Laparoscopic omentectomy for peritoneal dialysis catheter flow obstruction: A case report and review of the literature

Author keywords

Laparoscopy; Omentectomy; Peritoneal catheters; Peritoneal dialysis

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CLINICAL FEATURE; HUMAN; LAPAROSCOPIC SURGERY; MALE; OBSTRUCTION; PERITONEAL CATHETER; PERITONEAL DIALYSIS; PRIORITY JOURNAL; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; TREATMENT OUTCOME;

EID: 0033023283     PISSN: 10517200     EISSN: None     Source Type: Journal    
DOI: 10.1097/00129689-199906000-00018     Document Type: Article
Times cited : (47)

References (29)
  • 1
    • 0024596686 scopus 로고
    • Value of peritoneoscopy for nonfunctioning continuous ambulatory peritoneal dialysis catheters
    • Smith DW, Rankin RA. Value of peritoneoscopy for nonfunctioning continuous ambulatory peritoneal dialysis catheters. Gastrointest Endosc 1989;35:90-2.
    • (1989) Gastrointest Endosc , vol.35 , pp. 90-92
    • Smith, D.W.1    Rankin, R.A.2
  • 2
    • 0026212321 scopus 로고
    • Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters
    • Kittur DS, Gazaway PM, Abidin MR. Laparoscopic repositioning of malfunctioning peritoneal dialysis catheters. Surg Laparosc Endosc 1991;1:179-82.
    • (1991) Surg Laparosc Endosc , vol.1 , pp. 179-182
    • Kittur, D.S.1    Gazaway, P.M.2    Abidin, M.R.3
  • 3
    • 0028913339 scopus 로고
    • Laparoscopic manipulation of a malfunctioning peritoneal dialysis catheter in a child
    • Graham SM, Flowers JL, Fritz K, Voigt R. Laparoscopic manipulation of a malfunctioning peritoneal dialysis catheter in a child. Surg Laparosc Endosc 1995;5:144-7.
    • (1995) Surg Laparosc Endosc , vol.5 , pp. 144-147
    • Graham, S.M.1    Flowers, J.L.2    Fritz, K.3    Voigt, R.4
  • 4
    • 0030330060 scopus 로고    scopus 로고
    • Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters
    • Brandt CP, Ricanati ES. Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters. Adv Perit Dial 1996; 12:223-6.
    • (1996) Adv Perit Dial , vol.12 , pp. 223-226
    • Brandt, C.P.1    Ricanati, E.S.2
  • 5
    • 0030011418 scopus 로고    scopus 로고
    • Laparoscopic epiplopexy of the greater omentum and epiploic appendices in the salvaging of dysfunctional peritoneal dialysis catheters
    • Crabtree JH, Fishman A. Laparoscopic epiplopexy of the greater omentum and epiploic appendices in the salvaging of dysfunctional peritoneal dialysis catheters. Surg Laparosc Endosc 1996; 6:176-80.
    • (1996) Surg Laparosc Endosc , vol.6 , pp. 176-180
    • Crabtree, J.H.1    Fishman, A.2
  • 6
    • 0031085592 scopus 로고    scopus 로고
    • Laparoscopic salvage of malfunctioning peritoneal catheters
    • Amerling R, Maile DV, Spivak H, et al. Laparoscopic salvage of malfunctioning peritoneal catheters. Surg Endosc 1997;11:249-52.
    • (1997) Surg Endosc , vol.11 , pp. 249-252
    • Amerling, R.1    Maile, D.V.2    Spivak, H.3
  • 7
    • 0031952617 scopus 로고    scopus 로고
    • A practical approach to laparoscopic surgery for malfunctioning peritoneal dialysis catheters
    • Barone GW, Johnson DD, Webb JW. A practical approach to laparoscopic surgery for malfunctioning peritoneal dialysis catheters. J Laparoendosc Adv Surg Tech 1998;8:19-23.
    • (1998) J Laparoendosc Adv Surg Tech , vol.8 , pp. 19-23
    • Barone, G.W.1    Johnson, D.D.2    Webb, J.W.3
  • 8
    • 0002428694 scopus 로고
    • Chronic peritoneal dialysis catheters: Effects of catheter design, materials, and location
    • Ash SR. Chronic peritoneal dialysis catheters: effects of catheter design, materials, and location. Semin Dialr 1990;3:39-46.
    • (1990) Semin Dialr , vol.3 , pp. 39-46
    • Ash, S.R.1
  • 9
    • 0344972800 scopus 로고    scopus 로고
    • Long-term experience with polyurethane, pail handle, coiled tip peritoneal dialysis catheters
    • Crabtree JH, Siddiqi RA, Chung JJ, Greenwald LT. Long-term experience with polyurethane, pail handle, coiled tip peritoneal dialysis catheters. ASAIO J 1998;44:309-13.
    • (1998) ASAIO J , vol.44 , pp. 309-313
    • Crabtree, J.H.1    Siddiqi, R.A.2    Chung, J.J.3    Greenwald, L.T.4
  • 10
    • 0032952287 scopus 로고    scopus 로고
    • Videolaparoscopic implantation of long-term peritoneal dialysis catheters
    • Crabtree JH, Fishman A. Videolaparoscopic implantation of long-term peritoneal dialysis catheters. Surg Endosc 1999;13:186-90.
    • (1999) Surg Endosc , vol.13 , pp. 186-190
    • Crabtree, J.H.1    Fishman, A.2
  • 11
    • 0021806650 scopus 로고
    • Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis
    • Wilson JAP, Swartz RD. Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis. Dig Dis Sci 1985:30:465-7.
    • (1985) Dig Dis Sci , vol.30 , pp. 465-467
    • Wilson, J.A.P.1    Swartz, R.D.2
  • 13
    • 0027257876 scopus 로고
    • Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients
    • Chao SH, Tsai TJ. Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients. Nephron 1993;65:157-8.
    • (1993) Nephron , vol.65 , pp. 157-158
    • Chao, S.H.1    Tsai, T.J.2
  • 14
    • 0028073865 scopus 로고
    • Laparoscopy: An alternative to surgery in patients treated with continuous ambulatory peritoneal dialysis
    • Mutter D, Marichal JF, Heibel F, Marescaux J, Hannedouche T. Laparoscopy: an alternative to surgery in patients treated with continuous ambulatory peritoneal dialysis. Nephron 1994;68: 334-7.
    • (1994) Nephron , vol.68 , pp. 334-337
    • Mutter, D.1    Marichal, J.F.2    Heibel, F.3    Marescaux, J.4    Hannedouche, T.5
  • 15
    • 0030163231 scopus 로고    scopus 로고
    • Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two-puncture technique
    • Nijhuis PHA, Smulders JF, Jakimowicz JJ. Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two-puncture technique. Surg Endosc 1996:10:676-9.
    • (1996) Surg Endosc , vol.10 , pp. 676-679
    • Nijhuis, P.H.A.1    Smulders, J.F.2    Jakimowicz, J.J.3
  • 16
    • 0032091284 scopus 로고    scopus 로고
    • Laparoscopic management of Tenckhoff catheters in continuous ambulatory peritoneal dialysis
    • Leung LC, Yiu MK, Man CW, Chan WH, Lee KW, Lau KW. Laparoscopic management of Tenckhoff catheters in continuous ambulatory peritoneal dialysis. Surg Endosc 1998:12:891-3.
    • (1998) Surg Endosc , vol.12 , pp. 891-893
    • Leung, L.C.1    Yiu, M.K.2    Man, C.W.3    Chan, W.H.4    Lee, K.W.5    Lau, K.W.6
  • 17
    • 0028509552 scopus 로고
    • Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter
    • Hughes CR, Angotti DM, Jubelirer RA. Laparoscopic repositioning of a continuous ambulatory peritoneal dialysis (CAPD) catheter. Surg Endosc 1994;8:1108-9.
    • (1994) Surg Endosc , vol.8 , pp. 1108-1109
    • Hughes, C.R.1    Angotti, D.M.2    Jubelirer, R.A.3
  • 18
    • 0030716754 scopus 로고    scopus 로고
    • Videolaparoscopy with partial omentectomy in patients on peritoneal dialysis
    • Campisi S, Cavatorta F, Ramo E, Varano P. Videolaparoscopy with partial omentectomy in patients on peritoneal dialysis. Perit Dial Int 1997:17:211-2.
    • (1997) Perit Dial Int , vol.17 , pp. 211-212
    • Campisi, S.1    Cavatorta, F.2    Ramo, E.3    Varano, P.4
  • 20
    • 0027970315 scopus 로고
    • Omentectomy with peritoneal catheter placement in acute renal failure
    • Pumford N, Cassey J, Uttley WS. Omentectomy with peritoneal catheter placement in acute renal failure. Nephron 1994;68:327-8.
    • (1994) Nephron , vol.68 , pp. 327-328
    • Pumford, N.1    Cassey, J.2    Uttley, W.S.3
  • 21
    • 0029682261 scopus 로고    scopus 로고
    • Peritonectomy procedures
    • Sugarbaker PH. Peritonectomy procedures. Cancer Treat Res 1996:82:235-53.
    • (1996) Cancer Treat Res , vol.82 , pp. 235-253
    • Sugarbaker, P.H.1
  • 22
    • 2442748400 scopus 로고
    • Cancer of the ovary
    • Baltimore: Urban & Schwarzenberg
    • Boyd ME. Cancer of the ovary. In: Practical gynecological surgery. Baltimore: Urban & Schwarzenberg, 1989:35-44.
    • (1989) Practical Gynecological Surgery , pp. 35-44
    • Boyd, M.E.1
  • 23
    • 0029009274 scopus 로고
    • Laparoscopic surgical procedures for early ovarian cancer
    • Chu KK, Chen FP, Chang SD. Laparoscopic surgical procedures for early ovarian cancer. Acta Obsted Gynecol Scand 1995;74: 391-401.
    • (1995) Acta Obsted Gynecol Scand , vol.74 , pp. 391-401
    • Chu, K.K.1    Chen, F.P.2    Chang, S.D.3
  • 24
    • 0029164320 scopus 로고
    • Laparoscopic staging of early ovarian cancer
    • Pomel C, Provencher D, Dauplat J, et al. Laparoscopic staging of early ovarian cancer. Gynecol Oncol 1995;58:301-6.
    • (1995) Gynecol Oncol , vol.58 , pp. 301-306
    • Pomel, C.1    Provencher, D.2    Dauplat, J.3
  • 25
    • 0028802912 scopus 로고
    • Malfunctioning peritoneal dialysis catheter repaired by laparoscopic surgery
    • Julian TB, Ribeiro U, Bruns F, Fraley D. Malfunctioning peritoneal dialysis catheter repaired by laparoscopic surgery. Perit Dial Int 1995;15:363-6.
    • (1995) Perit Dial Int , vol.15 , pp. 363-366
    • Julian, T.B.1    Ribeiro, U.2    Bruns, F.3    Fraley, D.4
  • 26
    • 0032222592 scopus 로고    scopus 로고
    • Videolaparoscopic peritoneal dialysis catheter implant and rescue procedures under local anesthesia with nitrous oxide pneumoperitoneum
    • Crabtree JH, Fishman A, Huen IT. Videolaparoscopic peritoneal dialysis catheter implant and rescue procedures under local anesthesia with nitrous oxide pneumoperitoneum. Adv Perit Dial 1998; 14:83-6.
    • (1998) Adv Perit Dial , vol.14 , pp. 83-86
    • Crabtree, J.H.1    Fishman, A.2    Huen, I.T.3
  • 27
    • 0032869777 scopus 로고    scopus 로고
    • Videoscopic surgery under local and regional anesthesia with helium abdominal insufflation
    • in press
    • Crabtree JH, Fishman A. Videoscopic surgery under local and regional anesthesia with helium abdominal insufflation. Surg Endosc (in press).
    • Surg Endosc
    • Crabtree, J.H.1    Fishman, A.2
  • 28
    • 0025230214 scopus 로고
    • Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD
    • Gibson DH, Heasley RN, Price JH, Doherty CC, Douglas JF. Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD. Clin Nephrol 1990;33:208.
    • (1990) Clin Nephrol , vol.33 , pp. 208
    • Gibson, D.H.1    Heasley, R.N.2    Price, J.H.3    Doherty, C.C.4    Douglas, J.F.5
  • 29
    • 0030195345 scopus 로고    scopus 로고
    • Radially expanding dilatation. A superior method of laparoscopic trocar access
    • Bhoyrul S, Mori T, Way W. Radially expanding dilatation. A superior method of laparoscopic trocar access. Surg Endosc 1996; 10:775-8.
    • (1996) Surg Endosc , vol.10 , pp. 775-778
    • Bhoyrul, S.1    Mori, T.2    Way, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.