메뉴 건너뛰기




Volumn 10, Issue 1, 2004, Pages 5-20

The impact of modeling complexity and two-phase flow parameters on the accuracy of system modeling for unitary air conditioners

Author keywords

[No Author keywords available]

Indexed keywords

COMPRESSORS; CONDENSERS (LIQUEFIERS); EVAPORATORS; HEAT EXCHANGERS; HEAT TRANSFER COEFFICIENTS; REFRIGERANTS; TWO PHASE FLOW;

EID: 0347764597     PISSN: 10789669     EISSN: None     Source Type: Journal    
DOI: 10.1080/10789669.2004.10391087     Document Type: Article
Times cited : (10)

References (24)
  • 1
    • 0000171681 scopus 로고
    • Correlation of liquid fraction in two-phase flow with application to liquid metals
    • Baroczy, C. J., 1965. Correlation of liquid fraction in two-phase flow with application to liquid metals. Chemical Engineering Progress Symposium Series, 61 (57):179–191.
    • (1965) Chemical Engineering Progress Symposium Series , vol.61 , Issue.57 , pp. 179-191
    • Baroczy, C.J.1
  • 2
    • 0000957106 scopus 로고
    • Effectiveness models for cooling towers and cooling coils
    • Braun, J. E., Klein, S. A., and Mitchell, J. W., 1989. Effectiveness models for cooling towers and cooling coils. ASHRAE Transactions, 95 (2):164–174.
    • (1989) ASHRAE Transactions , vol.95 , Issue.2 , pp. 164-174
    • Braun, J.E.1    Klein, S.A.2    Mitchell, J.W.3
  • 8
    • 0000351691 scopus 로고
    • New equations for heat and mass transfer in turbulent pipe and channel flow
    • Gnielinski, V., 1976. New equations for heat and mass transfer in turbulent pipe and channel flow. Int. Chem. Eng., Vol. 16:359–368.
    • (1976) Int. Chem. Eng. , vol.16 , pp. 359-368
    • Gnielinski, V.1
  • 9
    • 0020717034 scopus 로고
    • Simple and explicit formulas for the friction factor in turbulent pipe flow
    • Haaland, S. E., 1983. Simple and explicit formulas for the friction factor in turbulent pipe flow. J. Fluids Eng., Vol. 105:89–90.
    • (1983) J. Fluids Eng. , vol.105 , pp. 89-90
    • Haaland, S.E.1
  • 12
    • 0038681895 scopus 로고    scopus 로고
    • Accurate charge inventory modeling for unitary air conditioners
    • Harms, T. M., Groll, E. A., and Braun, J. E., 2003. Accurate charge inventory modeling for unitary air conditioners. HVAC&R Research, Vol. 9:55–78.
    • (2003) HVAC&R Research , vol.9 , pp. 55-78
    • Harms, T.M.1    Groll, E.A.2    Braun, J.E.3
  • 13
    • 0001824533 scopus 로고
    • Holdup in gas-liquid flow
    • Hughmark, G. A., 1962. Holdup in gas-liquid flow. Chem. Eng. Progress, Vol. 58:62–65.
    • (1962) Chem. Eng. Progress , vol.58 , pp. 62-65
    • Hughmark, G.A.1
  • 15
    • 0031337514 scopus 로고    scopus 로고
    • Predicting flow boiling heat transfer of refrigerants in microfin tubes
    • Kandlikar, S. G., and Raykoff, T., 1997. Predicting flow boiling heat transfer of refrigerants in microfin tubes. Enhanced Heat Transfer, Vol. 4:257–268.
    • (1997) Enhanced Heat Transfer , vol.4 , pp. 257-268
    • Kandlikar, S.G.1    Raykoff, T.2
  • 16
    • 0033715989 scopus 로고    scopus 로고
    • Evaluating the accuracy of PUREZ in predicting unitary equipment performance
    • LeRoy, J. T., Groll, E. A., and Braun, J. E., 2000. Evaluating the accuracy of PUREZ in predicting unitary equipment performance. ASHRAE Transactions, 106 (1):200–215.
    • (2000) ASHRAE Transactions , vol.106 , Issue.1 , pp. 200-215
    • LeRoy, J.T.1    Groll, E.A.2    Braun, J.E.3
  • 17
    • 0027886754 scopus 로고
    • Assessing the capability of the HPSIM program to simulate room air conditioners
    • Marques, M. E., and Melo, C., 1993. Assessing the capability of the HPSIM program to simulate room air conditioners. ASHRAE Transactions, 99 (2):309–316.
    • (1993) ASHRAE Transactions , vol.99 , Issue.2 , pp. 309-316
    • Marques, M.E.1    Melo, C.2
  • 18
    • 0014994668 scopus 로고
    • Una correlazione adimensionale per la determinazione della densità di miscele bifasiche
    • Premoli, A., Di Francesco, D., and Prina, A., 1971. Una correlazione adimensionale per la determinazione della densità di miscele bifasiche. La Termotecnica, Vol. 25:17–26.
    • (1971) La Termotecnica , vol.25 , pp. 17-26
    • Premoli, A.1    Di Francesco, D.2    Prina, A.3
  • 19
    • 0023532482 scopus 로고
    • The effect of void fraction correlation and heat flux assumption on refrigerant charge inventory predictions
    • Rice, C. K., 1987. The effect of void fraction correlation and heat flux assumption on refrigerant charge inventory predictions. ASHRAE Transactions, 93 (1):341–367.
    • (1987) ASHRAE Transactions , vol.93 , Issue.1 , pp. 341-367
    • Rice, C.K.1
  • 22
  • 24
    • 84983128782 scopus 로고
    • Estimation of steady-state steam void-fraction by means of the principle of minimum entropy production
    • Zivi, S. M., 1964. Estimation of steady-state steam void-fraction by means of the principle of minimum entropy production. J. Heat Transfer, Vol. 86:247–252.
    • (1964) J. Heat Transfer , vol.86 , pp. 247-252
    • Zivi, S.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.