메뉴 건너뛰기




Volumn 37, Issue 1, 2004, Pages 135-140

In vivo tendon force measurement of 2-week duration in sheep

Author keywords

Muscle force; Sensor,In vivo; Shoulder; Tendon tension measurement

Indexed keywords

BIOSENSORS; BONE; STRESS ANALYSIS; TENDONS;

EID: 0347627536     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(03)00260-4     Document Type: Article
Times cited : (26)

References (21)
  • 3
    • 19244386925 scopus 로고    scopus 로고
    • A low profile human tendon force transducer the influence of tendon thickness on calibration
    • Dennerlein J.T., Miller J.M., Mote C.D., Rempel D.M. Jr. A low profile human tendon force transducer the influence of tendon thickness on calibration. Journal of Biomechanics. 30:1997;395-397.
    • (1997) Journal of Biomechanics , vol.30 , pp. 395-397
    • Dennerlein, J.T.1    Miller, J.M.2    Mote, C.D.3    Rempel Jr., D.M.4
  • 4
    • 0036000235 scopus 로고    scopus 로고
    • Influence of loading rate and cable migration on fiberoptic measurement of tendon force
    • Erdemir A., Piazza S.J., Sharkey N.A. Influence of loading rate and cable migration on fiberoptic measurement of tendon force. Journal of Biomechanics. 35:2002;857-862.
    • (2002) Journal of Biomechanics , vol.35 , pp. 857-862
    • Erdemir, A.1    Piazza, S.J.2    Sharkey, N.A.3
  • 5
    • 0027446242 scopus 로고
    • An in vivo comparison of anterior tibial translation and strain in the anteromedial band of the anterior cruciate ligament
    • Fleming B.C., Beynnon B.D., Nichols C.E., Johnson R.J., Pope M.H. An in vivo comparison of anterior tibial translation and strain in the anteromedial band of the anterior cruciate ligament. Journal of Biomechanics. 26:1993;51-58.
    • (1993) Journal of Biomechanics , vol.26 , pp. 51-58
    • Fleming, B.C.1    Beynnon, B.D.2    Nichols, C.E.3    Johnson, R.J.4    Pope, M.H.5
  • 9
    • 0033080799 scopus 로고    scopus 로고
    • Rate-independent characteristics of an arthroscopically implantable force probe in the human achilles tendon
    • Hall G.W., Crandall J.R., Carmines D.V., Hale J.E. Rate-independent characteristics of an arthroscopically implantable force probe in the human achilles tendon. Journal of Biomechanics. 32:1999;203-207.
    • (1999) Journal of Biomechanics , vol.32 , pp. 203-207
    • Hall, G.W.1    Crandall, J.R.2    Carmines, D.V.3    Hale, J.E.4
  • 10
    • 0030032281 scopus 로고    scopus 로고
    • Evaluation of the implantable force transducer for chronic tendon-force recordings
    • Herzog W., Archambault J.M., Leonard T.R., Nguyen H.K. Evaluation of the implantable force transducer for chronic tendon-force recordings. Journal of Biomechanics. 29:1996;103-109.
    • (1996) Journal of Biomechanics , vol.29 , pp. 103-109
    • Herzog, W.1    Archambault, J.M.2    Leonard, T.R.3    Nguyen, H.K.4
  • 11
    • 0030560666 scopus 로고    scopus 로고
    • In situ calibration of the implantable force transducer
    • Herzog W., Hasler E.M., Leonard T.R. In situ calibration of the implantable force transducer. Journal of Biomechanics. 29:1996;1649-1652.
    • (1996) Journal of Biomechanics , vol.29 , pp. 1649-1652
    • Herzog, W.1    Hasler, E.M.2    Leonard, T.R.3
  • 13
    • 0028958365 scopus 로고
    • Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force
    • Holden J.P., Grood E.S., Cummings J.F. Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force. Journal of Biomechanics. 28:1995;99-102.
    • (1995) Journal of Biomechanics , vol.28 , pp. 99-102
    • Holden, J.P.1    Grood, E.S.2    Cummings, J.F.3
  • 14
    • 0016831221 scopus 로고
    • A method for recording tendon strain in sheep during locomotion
    • Kear M., Smith R.N. A method for recording tendon strain in sheep during locomotion. Acta Orthopaedica Scandinavica. 46:1975;896-905.
    • (1975) Acta Orthopaedica Scandinavica , vol.46 , pp. 896-905
    • Kear, M.1    Smith, R.N.2
  • 15
    • 0023094793 scopus 로고
    • In vivo registration of achilles tendon forces in man i methodological development
    • Komi P.V., Salonen M., Jarvinen M., Kokko O. In vivo registration of achilles tendon forces in man i methodological development. International Journal of Sports Medicine. 1(Suppl. 8):1987;3-8.
    • (1987) International Journal of Sports Medicine , vol.1 , Issue.SUPPL. 8 , pp. 3-8
    • Komi, P.V.1    Salonen, M.2    Jarvinen, M.3    Kokko, O.4
  • 19
    • 0032411731 scopus 로고    scopus 로고
    • Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements
    • Rupert M., Grood E., Byczkowski T., Levy M. Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements. Journal of Biomechanical Engineering. 120:1998;764-769.
    • (1998) Journal of Biomechanical Engineering , vol.120 , pp. 764-769
    • Rupert, M.1    Grood, E.2    Byczkowski, T.3    Levy, M.4
  • 20
    • 0031170809 scopus 로고    scopus 로고
    • The monitoring of tendon tension with an implantable intratendon probe and its use in the control of neuroprostheses
    • Scott T.R., Bhadra N., Kilgore K.L., Peckham P.H. The monitoring of tendon tension with an implantable intratendon probe and its use in the control of neuroprostheses. IEEE Transactions on Rehabilitation Engineering. 5:1997;233-235.
    • (1997) IEEE Transactions on Rehabilitation Engineering , vol.5 , pp. 233-235
    • Scott, T.R.1    Bhadra, N.2    Kilgore, K.L.3    Peckham, P.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.