메뉴 건너뛰기




Volumn 3, Issue 3, 2001, Pages 641-648

Chalcogenide glasses as sensitive membranes for the detection of ions in solution

Author keywords

Cu ge sb se film; Cu2+ detection; Ion selective electrode; ISFET; Sulphide detection

Indexed keywords

ARSENIC COMPOUNDS; CHALCOGENIDES; CHEMICAL SENSORS; GLASS CERAMICS; ION SELECTIVE ELECTRODES; ION SENSITIVE FIELD EFFECT TRANSISTORS; IONS; SULFUR COMPOUNDS; THIN FILMS;

EID: 0347236490     PISSN: 14544164     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (10)
  • 2
    • 0001607852 scopus 로고
    • Chalcogenide glass chemical sensors research and analytical applications
    • Yu. G. Vlasov, E. A. Bychkov, A. V. Legin, Chalcogenide glass chemical sensors research and analytical applications, Talanta 41 (6), 1059-1063 (1994).
    • (1994) Talanta , vol.41 , Issue.6 , pp. 1059-1063
    • Vlasov, Y.G.1    Bychkov, E.A.2    Legin, A.V.3
  • 4
    • 0342849481 scopus 로고
    • Silver Bromide Based Chalcogenide Glassy - Crystalline Ion-selective Electrodes
    • Y. G. Vlasov, L. N. Moskvin, E. A. Bychkov, D. V. Golikov, Silver Bromide Based Chalcogenide Glassy - Crystalline Ion-selective Electrodes, Analyst, 114, 185-190 (1989).
    • (1989) Analyst , vol.114 , pp. 185-190
    • Vlasov, Y.G.1    Moskvin, L.N.2    Bychkov, E.A.3    Golikov, D.V.4
  • 5
    • 0035369510 scopus 로고    scopus 로고
    • Determination of sulfur species using a glassy - Cristalline chalcogenide membrane
    • C. Cali, G. Taillades, A. Pradel, M. Ribes, Determination of sulfur species using a glassy - cristalline chalcogenide membrane, Sensors and Actuators B 76, 560-564 (2001).
    • (2001) Sensors and Actuators B , vol.76 , pp. 560-564
    • Cali, C.1    Taillades, G.2    Pradel, A.3    Ribes, M.4
  • 8
    • 0033358346 scopus 로고    scopus 로고
    • ISE and ISFET microsensors based on a sensitive chalcogenide glass for copper ion detection in solution
    • G. Taillades, O. Valls, A. Bratov, C. Dominguez, A. Pradel, M. Ribes, ISE and ISFET microsensors based on a sensitive chalcogenide glass for copper ion detection in solution, Sensors and Actuators B 59, 123-127 (1999).
    • (1999) Sensors and Actuators B , vol.59 , pp. 123-127
    • Taillades, G.1    Valls, O.2    Bratov, A.3    Dominguez, C.4    Pradel, A.5    Ribes, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.