메뉴 건너뛰기




Volumn 284, Issue 1-2, 2004, Pages 15-26

Characterization and performance evaluation of in vivo and in vitro produced monoclonal anti-TNT antibodies for the detection of TNT

Author keywords

Antibody; Explosives; Fluorescence; Immunosensor; Microcapillary; TNT

Indexed keywords

AROMATIC NITRO COMPOUND; FLUORESCENT DYE; METHYL 2,4,6 TRINITROTOLUENE; MONOCLONAL ANTIBODY; TRINITROBENZENE; TRINITROTOLUENE ANTIBODY; UNCLASSIFIED DRUG;

EID: 0347003699     PISSN: 00221759     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jim.2003.09.010     Document Type: Article
Times cited : (24)

References (27)
  • 1
    • 0035356569 scopus 로고    scopus 로고
    • Immunochemical approaches for purification and detection of TNT traces by antibodies entrapped in a sol-gel matrix
    • Altstein M., Bronshtein A., Glattstein B., Zeichner A., Tamiri T., Almog J. Immunochemical approaches for purification and detection of TNT traces by antibodies entrapped in a sol-gel matrix. Anal. Chem. 73:2001;2461-2467.
    • (2001) Anal. Chem. , vol.73 , pp. 2461-2467
    • Altstein, M.1    Bronshtein, A.2    Glattstein, B.3    Zeichner, A.4    Tamiri, T.5    Almog, J.6
  • 4
    • 84862448094 scopus 로고    scopus 로고
    • Cell Essentials, www.cell-essentials.com/custom-monoclonal-frameset.htm.
    • Cell Essentials
  • 5
    • 0033617515 scopus 로고    scopus 로고
    • Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor
    • Charles P.T., Kusterbeck A.W. Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor. Biosens. Bioelectron. 14:1999;387-396.
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 387-396
    • Charles, P.T.1    Kusterbeck, A.W.2
  • 7
    • 0003586671 scopus 로고    scopus 로고
    • Field sampling and selecting on-site analytical methods for explosives in soil
    • Washington, DC: U.S. Government Printing Office
    • Crockett A.B., Craig H.D., Jenkins T.F., Sisk W.E. Field sampling and selecting on-site analytical methods for explosives in soil. Federal Facilities Forum Issue; EPA/540/R-97/50. 1996;1-32 U.S. Government Printing Office, Washington, DC.
    • (1996) Federal Facilities Forum Issue; EPA/540/R-97/50 , pp. 1-32
    • Crockett, A.B.1    Craig, H.D.2    Jenkins, T.F.3    Sisk, W.E.4
  • 8
    • 0023613109 scopus 로고
    • Characterization of five monoclonal antibodies obtained after immunization in vitro with a synthetic 19-amino acid peptide of thyroglobulin
    • de Boer M., Admiraal P., Kok K., Ossendorp F.A., de Vijlder J.J., Tager J.M. Characterization of five monoclonal antibodies obtained after immunization in vitro with a synthetic 19-amino acid peptide of thyroglobulin. Hybridoma. 6(6):1987;655-662.
    • (1987) Hybridoma , vol.6 , Issue.6 , pp. 655-662
    • De Boer, M.1    Admiraal, P.2    Kok, K.3    Ossendorp, F.A.4    De Vijlder, J.J.5    Tager, J.M.6
  • 11
    • 0036854847 scopus 로고    scopus 로고
    • Detection of 2,4,6-trinitrotoluene in seawater using a reversed-displacement immunosensor
    • Greene T.M., Charles P.T., Anderson G.P. Detection of 2,4,6-trinitrotoluene in seawater using a reversed-displacement immunosensor. Anal. Biochem. 310:2002;36-41.
    • (2002) Anal. Biochem. , vol.310 , pp. 36-41
    • Greene, T.M.1    Charles, P.T.2    Anderson, G.P.3
  • 12
    • 0032862203 scopus 로고    scopus 로고
    • Dip-and-read test strips for the determination of trinitrotoluene (TNT) in drinking water
    • Heiss C., Weller M.G., Niessner R. Dip-and-read test strips for the determination of trinitrotoluene (TNT) in drinking water. Anal. Chim. Acta. 396:1999;309-316.
    • (1999) Anal. Chim. Acta , vol.396 , pp. 309-316
    • Heiss, C.1    Weller, M.G.2    Niessner, R.3
  • 13
    • 0035659540 scopus 로고    scopus 로고
    • An optical tweezers-based immunosensor for detection of femtomoles-per-liter concentrations of antigens
    • Helmerson K., Kishore R., Phillips W.D., Weetall H.H. An optical tweezers-based immunosensor for detection of femtomoles-per-liter concentrations of antigens. Appl. Biochem. Biotechnol. 96:2001;205-213.
    • (2001) Appl. Biochem. Biotechnol. , vol.96 , pp. 205-213
    • Helmerson, K.1    Kishore, R.2    Phillips, W.D.3    Weetall, H.H.4
  • 16
    • 0347065260 scopus 로고    scopus 로고
    • Displacement immunoassay for TNT and RDX using continuous flow immunosensor
    • V. Lopez-Avila, D. Barcelo, W. Beckert, S.T. Goheen, K. Jinno, L.H. Keith, Rittenburg J.H. New York, NY: John Wiley & Sons, Inc.
    • Kusterbeck A.W., Charles P., Patterson C., Gauger P. Displacement immunoassay for TNT and RDX using continuous flow immunosensor. Lopez-Avila V., Barcelo D., Beckert W., Goheen S.T., Jinno K., Keith L.H., Rittenburg J.H. Current Protocol in Field Analytical Chemistry. Suppl. 4:2000;2C.11.1-2C.11.14 John Wiley & Sons, Inc. New York, NY.
    • (2000) Current Protocol in Field Analytical Chemistry , vol.4 , pp. 2111-21114
    • Kusterbeck, A.W.1    Charles, P.2    Patterson, C.3    Gauger, P.4
  • 17
    • 0036139997 scopus 로고    scopus 로고
    • Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion
    • Naal Z., Park J.H., Bernhard S., Shapleigh J., Batt C.A., Abruna H.D. Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion. Anal. Chem. 74:2002;140-148.
    • (2002) Anal. Chem. , vol.74 , pp. 140-148
    • Naal, Z.1    Park, J.H.2    Bernhard, S.3    Shapleigh, J.4    Batt, C.A.5    Abruna, H.D.6
  • 18
    • 0000529434 scopus 로고    scopus 로고
    • A displacement flow immunosensor for explosive detection using microcapillaries
    • Narang U., Gauger P.R., Ligler F.S. A displacement flow immunosensor for explosive detection using microcapillaries. Anal. Chem. 69:1997;2779-2785.
    • (1997) Anal. Chem. , vol.69 , pp. 2779-2785
    • Narang, U.1    Gauger, P.R.2    Ligler, F.S.3
  • 19
    • 0031974212 scopus 로고    scopus 로고
    • Multi-analyte detection using a capillary-based flow immunosensor
    • Narang U., Gauger P.R., Kusterbeck A.W., Ligler F.S. Multi-analyte detection using a capillary-based flow immunosensor. Anal. Biochem. 255:1998;13-19.
    • (1998) Anal. Biochem. , vol.255 , pp. 13-19
    • Narang, U.1    Gauger, P.R.2    Kusterbeck, A.W.3    Ligler, F.S.4
  • 23
    • 0036500859 scopus 로고    scopus 로고
    • Demonstration of four immunoassay formats using the array biosensor
    • Sapsford K.E., Charles P.T., Patterson C.H. Jr., Ligler F.S. Demonstration of four immunoassay formats using the array biosensor. Anal. Chem. 74:2002;1061-1068.
    • (2002) Anal. Chem. , vol.74 , pp. 1061-1068
    • Sapsford, K.E.1    Charles, P.T.2    Patterson, C.H.Jr.3    Ligler, F.S.4
  • 27
    • 5644244614 scopus 로고    scopus 로고
    • Characterization of a monoclonal anti-TNT antibody by measurement of the cross-reactivities of nitroaromatic compounds
    • Zeck A., Weller M., Niessner R. Characterization of a monoclonal anti-TNT antibody by measurement of the cross-reactivities of nitroaromatic compounds. Fresenius' J. Anal. Chem. 364:1999;113-120.
    • (1999) Fresenius' J. Anal. Chem. , vol.364 , pp. 113-120
    • Zeck, A.1    Weller, M.2    Niessner, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.