Volumn 13, Issue 9, 1998, Pages 939-944

A membrane-based displacement flow immunoassay

Author keywords

Biosensor; Displacement immunoassay; Explosives detection; Immobilized IgG; Membrane

Indexed keywords

ANTIBODIES; ANTIGENS; FLUOROMETERS; MEMBRANES; POROUS MATERIALS; REACTION KINETICS;

EID: 0032532438     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(98)00031-1     Document Type: Article
Times cited : (29)

References (19)
  • 1
    • 0029090039 scopus 로고
    • Early serum cardiac troponin I and T concentrations after successful thrombolysis for acute myocardial infarction
    • Apple, F.S., Sharkey, S.W., Henry, T.D., 1995. Early serum cardiac troponin I and T concentrations after successful thrombolysis for acute myocardial infarction. Clinical Chemistry 41, 1197-1198.
    • (1995) Clinical Chemistry , vol.41 , pp. 1197-1198
    • Apple, F.S.1    Sharkey, S.W.2    Henry, T.D.3
  • 4
    • 0025449522 scopus 로고
    • Fiber optic evanescent wave immunosensor for medical diagnostics
    • Bluestein, B.I., Walczak, I.M., Chen, S., 1990. Fiber optic evanescent wave immunosensor for medical diagnostics. TIBTECH 8, 161-168.
    • (1990) TIBTECH , vol.8 , pp. 161-168
    • Bluestein, B.I.1    Walczak, I.M.2    Chen, S.3
  • 6
    • 0028267811 scopus 로고
    • Comparison of solid-phase extraction with salting-out solvent extraction for preconcentration of nitroaromatic and nitramine explosives from water
    • Jenkins, T.F., Miyares, P.H., Myers, K.F., McCormick, E.F., Strong, A.B., 1994. Comparison of solid-phase extraction with salting-out solvent extraction for preconcentration of nitroaromatic and nitramine explosives from water. Analytica Chimica Acta. 289, 69-78.
    • (1994) Analytica Chimica Acta. , vol.289 , pp. 69-78
    • Jenkins, T.F.1    Miyares, P.H.2    Myers, K.F.3    McCormick, E.F.4    Strong, A.B.5
  • 9
    • 0000529433 scopus 로고    scopus 로고
    • Capillary-based displacement flow immunosensor
    • Narang, U., Gauger, P.R., Ligler, F.S., 1997. Capillary-based displacement flow immunosensor. Anal. Chem. 69, 1961-1964.
    • (1997) Anal. Chem. , vol.69 , pp. 1961-1964
    • Narang, U.1    Gauger, P.R.2    Ligler, F.S.3
  • 12
    • 0028281492 scopus 로고
    • Effect of antibody density on the displacement kinetics of a flow immunoassay
    • Rabbany, S.Y., Kusterbeck, A.W., Bredehorst, R., Ligler, F.S., 1994b. Effect of antibody density on the displacement kinetics of a flow immunoassay. J. Immunol Meth. 168, 227-234.
    • (1994) J. Immunol Meth. , vol.168 , pp. 227-234
    • Rabbany, S.Y.1    Kusterbeck, A.W.2    Bredehorst, R.3    Ligler, F.S.4
  • 17
    • 11944273749 scopus 로고
    • Immunochemical methods for environmental analysis
    • Van Emon, J.M., Lopez-Avila, V., 1992. Immunochemical methods for environmental analysis. Anal. Chem. 64, 79A-88A.
    • (1992) Anal. Chem. , vol.64
    • Van Emon, J.M.1    Lopez-Avila, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.