메뉴 건너뛰기




Volumn 9, Issue 2, 2000, Pages

Cartilage Tissue Engineering for Ear as in Rabbit Model with Perforated Polyurethane Prosthesis: In Vivo Assay

Author keywords

Biocompatibility; Ear cartilage; Perforated polyurethane (PPU); Tissue engineering

Indexed keywords


EID: 0346356013     PISSN: 10261265     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (13)
  • 4
    • 0026031689 scopus 로고
    • Improved tissue ingrowth and anchorage of expanded polytetrafluoroethylene by perforation: An experimental study in the rat
    • Roger K.J. Simmermacher, Berend Van der Lei, Jeff M. Schakenraad and Robert P. Bleichrodt, Improved tissue ingrowth and anchorage of expanded polytetrafluoroethylene by perforation: an experimental study in the rat, Biomaterials, 12, 22-24, 1991.
    • (1991) Biomaterials , vol.12 , pp. 22-24
    • Simmermacher, R.K.J.1    Van Der Lei, B.2    Schakenraad, J.M.3    Bleichrodt, R.P.4
  • 5
    • 0017976762 scopus 로고
    • Effect of polyurethane morphology on blood coagulation
    • Picha G.J., Gibbon S.D.F., and Averbach R.A., Effect of polyurethane morphology on blood coagulation. J Bioeng., 2, 301, 1978.
    • (1978) J Bioeng. , vol.2 , pp. 301
    • Picha, G.J.1    Gibbon, S.D.F.2    Averbach, R.A.3
  • 6
    • 0022044622 scopus 로고
    • Polyurethane ionomers surface properties/ex-vivo blood comp-atibility relationships
    • Lelah M.D., Pierce J.A., Lambrecht L.K. and Cooper S.L., Polyurethane ionomers surface properties/ex-vivo blood comp-atibility relationships. J. Colloid Interface Sci., 104, 422, 1985.
    • (1985) J. Colloid Interface Sci. , vol.104 , pp. 422
    • Lelah, M.D.1    Pierce, J.A.2    Lambrecht, L.K.3    Cooper, S.L.4
  • 7
    • 0018872656 scopus 로고
    • In-vivo evaluation of artificial surfaces with non-human primate model of arterial thrombosis
    • Hanson S.R., Harker L.A., Ratner B.D. and Hoffman A.S., In-vivo evaluation of artificial surfaces with non-human primate model of arterial thrombosis. J. Lab. Clin. Med., 95, 289, 1980.
    • (1980) J. Lab. Clin. Med. , vol.95 , pp. 289
    • Hanson, S.R.1    Harker, L.A.2    Ratner, B.D.3    Hoffman, A.S.4
  • 8
    • 0031081416 scopus 로고    scopus 로고
    • Enhancement of cell-growth and cell adhesion factors
    • Yoshihiro Ito, di Zheng and Yukiro Imanishi, Enhancement of cell-growth and cell adhesion factors, Biomaterials, 18, 197, 1997.
    • (1997) Biomaterials , vol.18 , pp. 197
    • Ito, Y.1    Zheng, D.2    Imanishi, Y.3
  • 10
    • 0024428631 scopus 로고
    • In vitro evaluation of hydrophobic and fibrillar microporous polyetherurethane urea graft
    • Marios Y. et al., In vitro evaluation of hydrophobic and fibrillar microporous polyetherurethane urea graft. Biomaterials, 10, 521, 1989.
    • (1989) Biomaterials , vol.10 , pp. 521
    • Marios, Y.1
  • 11
    • 0345839440 scopus 로고    scopus 로고
    • Synthesis and characterization of isocyanate-terminated urethane prepolymer considered as bioadhesive base material
    • in press
    • Mirzadeh H., Sheikh N. and Katbab A.A., Synthesis and characterization of isocyanate-terminated urethane prepolymer considered as bioadhesive base material, Int. J. Adh. & Adhes., (in press), 2000.
    • (2000) Int. J. Adh. & Adhes.
    • Mirzadeh, H.1    Sheikh, N.2    Katbab, A.A.3
  • 13
    • 0030070098 scopus 로고    scopus 로고
    • Use of porous polyurethanes for meniscal reconstruction and meniscal prostheses
    • de Groot J.H. et al., Use of porous polyurethanes for meniscal reconstruction and meniscal prostheses, Biomaterials, 17, 163, 1996.
    • (1996) Biomaterials , vol.17 , pp. 163
    • De Groot, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.