메뉴 건너뛰기




Volumn 19, Issue 7, 2004, Pages 711-720

A novel piezoelectric quartz micro-array immunosensor based on self-assembled monolayer for determination of human chorionic gonadotropin

Author keywords

Human chorionic gonadotropin (hCG); Immunosensor; Piezoelectric quartz crystal; Self assembled monolayer (SAM)

Indexed keywords

ANTIBODIES; CORRELATION METHODS; CRYSTALS; ELECTRODES; GOLD; PIEZOELECTRICITY; QUARTZ; SELF ASSEMBLY;

EID: 0346094451     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(03)00260-4     Document Type: Article
Times cited : (72)

References (38)
  • 1
    • 0242349204 scopus 로고    scopus 로고
    • Elevated hCG and a high proportion of hCG in serum preceding the diagnosis of trophoblastic disease by seven months
    • Alfthan H.-L., Lehtovirta P., Stenman U.-H. Elevated hCG and a high proportion of hCG in serum preceding the diagnosis of trophoblastic disease by seven months. BJOG: Int. J. Obstet. Gynaecol. 109(5):2002;589-590.
    • (2002) BJOG: Int. J. Obstet. Gynaecol. , vol.109 , Issue.5 , pp. 589-590
    • Alfthan, H.-L.1    Lehtovirta, P.2    Stenman, U.-H.3
  • 2
    • 0034351355 scopus 로고    scopus 로고
    • Evaluation of antibody immobilization methods for piezoelectric biosensor apllication
    • Babacan S., Pivarnik P., Letcher S., Rand A.G. Evaluation of antibody immobilization methods for piezoelectric biosensor apllication. Biosens. Bioelectr. 15:2000;615-621.
    • (2000) Biosens. Bioelectr. , vol.15 , pp. 615-621
    • Babacan, S.1    Pivarnik, P.2    Letcher, S.3    Rand, A.G.4
  • 3
    • 33845184543 scopus 로고
    • Formation of monolayers by coadsorption of thiols on gold: Variation in the head group, tail group, and solvent
    • Bain C.D., Evall J., Whitesides G.M. Formation of monolayers by coadsorption of thiols on gold: variation in the head group, tail group, and solvent. J. Am. Chem. Soc. 111:1989;7155-7164.
    • (1989) J. Am. Chem. Soc. , vol.111 , pp. 7155-7164
    • Bain, C.D.1    Evall, J.2    Whitesides, G.M.3
  • 4
    • 0001625441 scopus 로고    scopus 로고
    • A piezoelectric immunosensor for the detection of cocaine
    • Bassam S.A., Ahmad A.S. A piezoelectric immunosensor for the detection of cocaine. Microchem. J. 54:1996;1747-1749.
    • (1996) Microchem. J. , vol.54 , pp. 1747-1749
    • Bassam, S.A.1    Ahmad, A.S.2
  • 5
    • 0024596397 scopus 로고
    • Use of thiol-terminal silanes and heterobifunctional crosslinkers for immunobilization of antibodies on silica surfaces
    • Bhatia S.K., Shriver-Lake L.C., Prior K.J. Use of thiol-terminal silanes and heterobifunctional crosslinkers for immunobilization of antibodies on silica surfaces. Anal. Biochem. 178:1989;408-413.
    • (1989) Anal. Biochem. , vol.178 , pp. 408-413
    • Bhatia, S.K.1    Shriver-Lake, L.C.2    Prior, K.J.3
  • 6
    • 0034733285 scopus 로고    scopus 로고
    • An improving method for determination of Escherichia coli population based on multi-channel series piezoelectric quartz crystal system
    • Chang B.-W., Hsu Y.-M., Chang H.C. An improving method for determination of Escherichia coli population based on multi-channel series piezoelectric quartz crystal system. Sens. Actuators, B. 65:2000;105-107.
    • (2000) Sens. Actuators, B , vol.65 , pp. 105-107
    • Chang, B.-W.1    Hsu, Y.-M.2    Chang, H.C.3
  • 7
    • 3743134422 scopus 로고
    • Synthesis, structure, and properties of model orgnic surfaces
    • Dubois L.H., Nuzzo R.G. Synthesis, structure, and properties of model orgnic surfaces. Annu. Rev. Phys. Chem. 43:1992;437-463.
    • (1992) Annu. Rev. Phys. Chem. , vol.43 , pp. 437-463
    • Dubois, L.H.1    Nuzzo, R.G.2
  • 8
    • 0024700777 scopus 로고
    • Ordor-sensing system using a quartz-resonantor sensor array and neural-network pattern recongnition
    • Ema K., Yokoyama M., Moriizumi T. Ordor-sensing system using a quartz-resonantor sensor array and neural-network pattern recongnition. Sens. Actuators. 18:1989;291-296.
    • (1989) Sens. Actuators , vol.18 , pp. 291-296
    • Ema, K.1    Yokoyama, M.2    Moriizumi, T.3
  • 10
    • 0026704470 scopus 로고
    • A piezoelectric immunobiosensor for atrazine in drinking water
    • Guibault G.G., Hock B., Schmid R. A piezoelectric immunobiosensor for atrazine in drinking water. Biosens. Bioelectr. 7:1992;411-419.
    • (1992) Biosens. Bioelectr. , vol.7 , pp. 411-419
    • Guibault, G.G.1    Hock, B.2    Schmid, R.3
  • 12
    • 0034994722 scopus 로고    scopus 로고
    • Investigation of highly sensitive piezoelectric immunosensors for 2, 4-dichlorophenoxyacetic acid
    • Jan H., Maria H., Petr S. Investigation of highly sensitive piezoelectric immunosensors for 2, 4-dichlorophenoxyacetic acid. Biosens. Bioelectr. 16:2001;253-260.
    • (2001) Biosens. Bioelectr. , vol.16 , pp. 253-260
    • Jan, H.1    Maria, H.2    Petr, S.3
  • 13
    • 0028372590 scopus 로고
    • A novel immunosensor for Hepatitis Virus
    • Koning B., Gratzel M. A novel immunosensor for Hepatitis Virus. Anal. Chem. 66:1994;341-344.
    • (1994) Anal. Chem. , vol.66 , pp. 341-344
    • Koning, B.1    Gratzel, M.2
  • 14
    • 0033969873 scopus 로고    scopus 로고
    • A reusable and specific protein A-coated piezoelectric biosensor for flow injection immunoassay
    • Lu H.-C., Chen H.-M., Lin Y.-S., Lin Y.-S., Lin J.-W. A reusable and specific protein A-coated piezoelectric biosensor for flow injection immunoassay. Biotechnol. Prog. 16(1):2000;116-124.
    • (2000) Biotechnol. Prog. , vol.16 , Issue.1 , pp. 116-124
    • Lu, H.-C.1    Chen, H.-M.2    Lin, Y.-S.3    Lin, Y.-S.4    Lin, J.-W.5
  • 15
    • 0033010806 scopus 로고    scopus 로고
    • An immunosensor: Immobilization of anti-HBs antibody on liow-discharge treated piezoelectric quartz crystals for HBs-Ag detection
    • Mutlu S., Saber R., Kocum C., Piskin E. An immunosensor: immobilization of anti-HBs antibody on liow-discharge treated piezoelectric quartz crystals for HBs-Ag detection. Anal. Lett. 32(2):1999;317-334.
    • (1999) Anal. Lett. , vol.32 , Issue.2 , pp. 317-334
    • Mutlu, S.1    Saber, R.2    Kocum, C.3    Piskin, E.4
  • 16
    • 0036136270 scopus 로고    scopus 로고
    • Self-assembled monolayers as a tunable platform for biosensor applications
    • Nirmalya K.C., Vijayamohanan K. Self-assembled monolayers as a tunable platform for biosensor applications. Biosens. Bioelectr. 17:2002;1-12.
    • (2002) Biosens. Bioelectr. , vol.17 , pp. 1-12
    • Nirmalya, K.C.1    Vijayamohanan, K.2
  • 17
    • 0000959170 scopus 로고
    • High-frequency impedance analysis of quartz crystal microbalances. 1. General considerations
    • Noel M.A.M., Topart P.A. High-frequency impedance analysis of quartz crystal microbalances. 1. General considerations. Anal. Chem. 66:1994;484-491.
    • (1994) Anal. Chem. , vol.66 , pp. 484-491
    • Noel, M.A.M.1    Topart, P.A.2
  • 18
    • 0032877877 scopus 로고    scopus 로고
    • Human chorionic gonadotropin: A secretory hormone
    • Panesar N.S. Human chorionic gonadotropin: a secretory hormone. Med. Hypotheses. 53(2):1999;136-140.
    • (1999) Med. Hypotheses , vol.53 , Issue.2 , pp. 136-140
    • Panesar, N.S.1
  • 19
    • 0032213121 scopus 로고    scopus 로고
    • Thiolated Salmonella typhimurium antibody immobilization onto the gold surface of piezoelectric quartz crystal
    • Park I.S., Kim N. Thiolated Salmonella typhimurium antibody immobilization onto the gold surface of piezoelectric quartz crystal. Biosens. Bioelectr. 13:1998;1091-1097.
    • (1998) Biosens. Bioelectr. , vol.13 , pp. 1091-1097
    • Park, I.S.1    Kim, N.2
  • 20
    • 0034210048 scopus 로고    scopus 로고
    • Operational characteristics of an antibody-immobilized QCM system detecting Salmonella spp
    • Park I.S., Kim W.Y., Kim N. Operational characteristics of an antibody-immobilized QCM system detecting Salmonella spp. Biosens. Bioelectr. 15:2000;167-172.
    • (2000) Biosens. Bioelectr. , vol.15 , pp. 167-172
    • Park, I.S.1    Kim, W.Y.2    Kim, N.3
  • 21
    • 0024322683 scopus 로고
    • Comparison of four bifunctional reagents for coupling peptides to proteins and the effect of the three moieties on the immunogenicity of the conjugates
    • Peeters J.M., Hazendonk T.G., Beuvery E.C. Comparison of four bifunctional reagents for coupling peptides to proteins and the effect of the three moieties on the immunogenicity of the conjugates. J. Immunol. Methods. 120:1989;133-143.
    • (1989) J. Immunol. Methods , vol.120 , pp. 133-143
    • Peeters, J.M.1    Hazendonk, T.G.2    Beuvery, E.C.3
  • 22
    • 0035449587 scopus 로고    scopus 로고
    • Molecular-imprinted, polymer-coated quartz crystal microbalances for the detection of terpenes
    • Percival C.J., Stanley S., Galle T.M. Molecular-imprinted, polymer-coated quartz crystal microbalances for the detection of terpenes. Anal. Chem. 73(17):2001;4225-4228.
    • (2001) Anal. Chem. , vol.73 , Issue.17 , pp. 4225-4228
    • Percival, C.J.1    Stanley, S.2    Galle, T.M.3
  • 23
    • 0026832837 scopus 로고
    • Development of piezoelectric immunosensor for the detection of Enterobacteria
    • Plomer M., Guilbault G.G., Hock B. Development of piezoelectric immunosensor for the detection of Enterobacteria. Enzyme Microb. Technol. 14:1992;230-235.
    • (1992) Enzyme Microb. Technol. , vol.14 , pp. 230-235
    • Plomer, M.1    Guilbault, G.G.2    Hock, B.3
  • 24
    • 0025404361 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium
    • Prusak-Sochaczewski E., Luong J.H.T., Guilbault G.G. Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme Microb. Technol. 12:1990;173-177.
    • (1990) Enzyme Microb. Technol. , vol.12 , pp. 173-177
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2    Guilbault, G.G.3
  • 25
    • 0027999228 scopus 로고
    • Determination of immunoglobulin M concentration by piezoelectric crystal immunobiosensor coated with protamine
    • Raman, C., Manoj, R., Gyan, C.M., 1994. Determination of immunoglobulin M concentration by piezoelectric crystal immunobiosensor coated with protamine, Biosens. Bioelectr. 9, 325-332.
    • (1994) Biosens. Bioelectr. , vol.9 , pp. 325-332
    • Raman, C.1    Manoj, R.2    Gyan, C.M.3
  • 26
    • 0346183644 scopus 로고    scopus 로고
    • Glow-discharge treated piezoelectric quartz crystals as immunosensors for HSA detection
    • Reza S., Selma M., Erhan P. Glow-discharge treated piezoelectric quartz crystals as immunosensors for HSA detection. Biosens. Bioelectr. 00:2002;1-8.
    • (2002) Biosens. Bioelectr. , vol.0 , pp. 1-8
    • Reza, S.1    Selma, M.2    Erhan, P.3
  • 28
    • 0035141202 scopus 로고    scopus 로고
    • Rapid detection of Salmonella enteritidis by piezoelectric immunosensor
    • Si S.-H., Li X., Fung Y.-H., Zhu D.R. Rapid detection of Salmonella enteritidis by piezoelectric immunosensor. Microchem. J. 68:2001;21-27.
    • (2001) Microchem. J. , vol.68 , pp. 21-27
    • Si, S.-H.1    Li, X.2    Fung, Y.-H.3    Zhu, D.R.4
  • 29
    • 0035668894 scopus 로고    scopus 로고
    • Applications to Fertility Research, Prenatal Diagnosis, and Cancer
    • Steven B., Galina K., John O. Applications to Fertility Research, Prenatal Diagnosis, and Cancer. Arch. Med. Res. 32(6):2001;635-643.
    • (2001) Arch. Med. Res. , vol.32 , Issue.6 , pp. 635-643
    • Steven, B.1    Galina, K.2    John, O.3
  • 30
    • 0034476132 scopus 로고    scopus 로고
    • Piezoelectric quartz crystal based label-free analysis for allergy disease
    • Su X.-D., Chew F.-T., Li S.F.Y. Piezoelectric quartz crystal based label-free analysis for allergy disease. Biosens. Bioelectr. 15:2000;629-639.
    • (2000) Biosens. Bioelectr. , vol.15 , pp. 629-639
    • Su, X.-D.1    Chew, F.-T.2    Li, S.F.Y.3
  • 31
    • 0034669585 scopus 로고    scopus 로고
    • Human cytomegalovirus detection by a quartz crystal microbalance immunosensor
    • Susmel S., O'Sullivan C.K., Guilbault G.G. Human cytomegalovirus detection by a quartz crystal microbalance immunosensor. Enzyme Microbial. Technol. 27:2000;639-645.
    • (2000) Enzyme Microbial. Technol. , vol.27 , pp. 639-645
    • Susmel, S.1    O'Sullivan, C.K.2    Guilbault, G.G.3
  • 32
    • 0033733557 scopus 로고    scopus 로고
    • One-chip multichannel quartz crystal microbalance (QCM) fabricated by Deep RIE
    • Takashi A., Masayosh E. One-chip multichannel quartz crystal microbalance (QCM) fabricated by Deep RIE. Sens. Actuators. 82:2000;139-143.
    • (2000) Sens. Actuators , vol.82 , pp. 139-143
    • Takashi, A.1    Masayosh, E.2
  • 34
    • 0032924587 scopus 로고    scopus 로고
    • A piezoelectric biosensor as an olfactory receptor for odour detection: Electronic nose
    • Wu T.-Z. A piezoelectric biosensor as an olfactory receptor for odour detection: electronic nose. Biosens. Bioelectr. 14:1999;1-13.
    • (1999) Biosens. Bioelectr. , vol.14 , pp. 1-13
    • Wu, T.-Z.1
  • 35
    • 0002894118 scopus 로고
    • Dependence of the oscillation frequency of a piezoelectric crystal on the physical parameters of liquids
    • Yao S.-Z., Zhou T.-A. Dependence of the oscillation frequency of a piezoelectric crystal on the physical parameters of liquids. Anal. Chim. Acta. 212:1988;61-72.
    • (1988) Anal. Chim. Acta , vol.212 , pp. 61-72
    • Yao, S.-Z.1    Zhou, T.-A.2
  • 36
    • 15444356204 scopus 로고    scopus 로고
    • Piezoelectric biosensor for detection of Salmonella typhimurium
    • Ye J., Letcher S.V., Rand A.G. Piezoelectric biosensor for detection of Salmonella typhimurium. J. Food Sci. 62(5):1997;1067-1071.
    • (1997) J. Food Sci. , vol.62 , Issue.5 , pp. 1067-1071
    • Ye, J.1    Letcher, S.V.2    Rand, A.G.3
  • 37
    • 0028946852 scopus 로고
    • Highly sensitive quartz crystal immunosensors for mutisample detection of herbicides
    • Yokoyama K., Ikebukuro K. Highly sensitive quartz crystal immunosensors for mutisample detection of herbicides. Anal. Chim. Acta. 304:1995;139-145.
    • (1995) Anal. Chim. Acta , vol.304 , pp. 139-145
    • Yokoyama, K.1    Ikebukuro, K.2
  • 38
    • 0037017669 scopus 로고    scopus 로고
    • Piezoelectric quartz crystal sensors based on ion-pair complexes for the determination of cinchonine in human serum and urine
    • Bo Zhang received his MS degree in 1996 and MD in 2002 in medical laboratory from Third Military Medical University
    • Yuan J.-B., Tan Y.-G., Nie L.-H., Yao S.-Z. Piezoelectric quartz crystal sensors based on ion-pair complexes for the determination of cinchonine in human serum and urine. Anal. Chim. Acta. 454:2002;65-74.
    • (2002) Anal. Chim. Acta , vol.454 , pp. 65-74
    • Yuan, J.-B.1    Tan, Y.-G.2    Nie, L.-H.3    Yao, S.-Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.