메뉴 건너뛰기




Volumn 12, Issue 6, 2003, Pages 752-757

Aortic root replacement with a new stentless aortic valve xenograft conduit: Preliminary hemodynamic and clinical results

Author keywords

[No Author keywords available]

Indexed keywords

GLUTARALDEHYDE; HEPARIN;

EID: 0345328597     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (21)
  • 1
    • 0026182002 scopus 로고
    • Composite graft replacement of the ascending aorta and aortic valve with the inclusion-wrap technique and open technique
    • Kouchoukos NT. Composite graft replacement of the ascending aorta and aortic valve with the inclusion-wrap technique and open technique. Semin Thorac Cardiovasc Surg 1991;3:171-176
    • (1991) Semin. Thorac. Cardiovasc. Surg. , vol.3 , pp. 171-176
    • Kouchoukos, N.T.1
  • 4
    • 0033001760 scopus 로고    scopus 로고
    • Aortic allograft and pulmonary autografts for replacement of the aortic valve and aortic root
    • Kouchoukos NT. Aortic allograft and pulmonary autografts for replacement of the aortic valve and aortic root. Ann Thorac Surg 1999;67:1846-1848
    • (1999) Ann. Thorac. Surg. , vol.67 , pp. 1846-1848
    • Kouchoukos, N.T.1
  • 5
    • 0034785152 scopus 로고    scopus 로고
    • Aortic valve-sparing operations for aortic root aneurysms
    • David TE. Aortic valve-sparing operations for aortic root aneurysms. Semin Thorac Cardiovasc Surg 2001;13:291-296
    • (2001) Semin. Thorac. Cardiovasc. Surg. , vol.13 , pp. 291-296
    • David, T.E.1
  • 6
    • 0033943970 scopus 로고    scopus 로고
    • Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: Technical considerations and early clinical results
    • Urbanski PP, Hacker RW. Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: technical considerations and early clinical results. Ann Thorac Surg 2000;70:17-20
    • (2000) Ann. Thorac. Surg. , vol.70 , pp. 17-20
    • Urbanski, P.P.1    Hacker, R.W.2
  • 7
    • 0030558236 scopus 로고    scopus 로고
    • No-React® detoxification process: A superior anticalcification method for bioprostheses
    • Albolhoda A, Yu S, Oyarzun J, et al. No-React® detoxification process: A superior anticalcification method for bioprostheses. Ann Thorac Surg 1996;62:1724-1730
    • (1996) Ann. Thorac. Surg. , vol.62 , pp. 1724-1730
    • Albolhoda, A.1    Yu, S.2    Oyarzun, J.3
  • 10
    • 0035138435 scopus 로고    scopus 로고
    • Stress analysis of the aortic valve with and without the sinuses of Valsalva
    • Beck A, Thubrikar MJ, Robicsek F. Stress analysis of the aortic valve with and without the sinuses of Valsalva. J Heart Valve Dis 2001;10:1-11
    • (2001) J. Heart Valve Dis. , vol.10 , pp. 1-11
    • Beck, A.1    Thubrikar, M.J.2    Robicsek, F.3
  • 13
    • 0033021272 scopus 로고    scopus 로고
    • Acute aortic endocarditis with annular destruction: Assessment of surgical treatment with cryopreserved valvular homografts
    • Grandmougin D, Prat A, Fayad G, Decoene C, Pol A, Waremboug H. Acute aortic endocarditis with annular destruction: Assessment of surgical treatment with cryopreserved valvular homografts. J Heart Valve Dis 1999;8:234-241
    • (1999) J. Heart Valve Dis. , vol.8 , pp. 234-241
    • Grandmougin, D.1    Prat, A.2    Fayad, G.3    Decoene, C.4    Pol, A.5    Waremboug, H.6
  • 16
    • 0032299979 scopus 로고    scopus 로고
    • Stentless xenograft repair of excavating root sepsis
    • Katsumata T, Vaccari G, Westaby S. Stentless xenograft repair of excavating root sepsis. J Card Surg 1998;13:440-444
    • (1998) J. Card. Surg. , vol.13 , pp. 440-444
    • Katsumata, T.1    Vaccari, G.2    Westaby, S.3
  • 17
    • 0345339652 scopus 로고    scopus 로고
    • The NR-2000C Stentless Aortic Valve Conduit: A breakthrough in bioprosthetic design
    • CE 0318 Technical report. Shelhigh, Inc., Milburn, NJ
    • CE 0318 Technical report. The NR-2000C Stentless Aortic Valve Conduit: A breakthrough in bioprosthetic design. Shelhigh, Inc., Milburn, NJ
  • 18
    • 0037336198 scopus 로고    scopus 로고
    • Stentless aortic valves as an alternative to homografts for valve replacement in active infective endocarditis complicated by ring abscess
    • Siniawski H, Lehmkuhl H, Wenig Y, et al. Stentless aortic valves as an alternative to homografts for valve replacement in active infective endocarditis complicated by ring abscess. Ann Thorac Surg 2003;75:803-808
    • (2003) Ann. Thorac. Surg. , vol.75 , pp. 803-808
    • Siniawski, H.1    Lehmkuhl, H.2    Wenig, Y.3
  • 19
    • 0036839845 scopus 로고    scopus 로고
    • Use of stentless xenografts in the aortic position: Determinants of early and late outcome
    • Akar AR, Szafranek A, Alexiou C, et al. Use of stentless xenografts in the aortic position: Determinants of early and late outcome. Ann Thorac Surg 2002;74:1450-1458
    • (2002) Ann. Thorac. Surg. , vol.74 , pp. 1450-1458
    • Akar, A.R.1    Szafranek, A.2    Alexiou, C.3
  • 21
    • 0035113611 scopus 로고    scopus 로고
    • The Shelhigh No-React porcine pulmonary valve conduit: A new alternative to the homograft
    • Marianeschi SM, Iacona GM, Seddio F, et al. The Shelhigh No-React porcine pulmonary valve conduit: A new alternative to the homograft. Ann Thorac Surg 2001;71:619-623
    • (2001) Ann. Thorac. Surg. , vol.71 , pp. 619-623
    • Marianeschi, S.M.1    Iacona, G.M.2    Seddio, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.