-
1
-
-
0027897650
-
In-vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of stress, motion, and alloy coupling
-
Gilbert JL, Buckley CA, Jacobs JJ. In-vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of stress, motion, and alloy coupling. J Biomed Mater Res 1993;27:1533-1544.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 1533-1544
-
-
Gilbert, J.L.1
Buckley, C.A.2
Jacobs, J.J.3
-
2
-
-
0028845164
-
Local and distant products from modularity
-
Jacobs JJ et al. Local and distant products from modularity. Clin Orthop 1995;319:94-105.
-
(1995)
Clin Orthop
, vol.319
, pp. 94-105
-
-
Jacobs, J.J.1
-
3
-
-
0026013091
-
Systemic effects of implanted prostheses made of cobalt chromium alloys
-
Michel R, Nolte M, Reich M, Loer F. Systemic effects of implanted prostheses made of cobalt chromium alloys. Arch Orthop Trauma Surg 1991;110:61-74.
-
(1991)
Arch Orthop Trauma Surg
, vol.110
, pp. 61-74
-
-
Michel, R.1
Nolte, M.2
Reich, M.3
Loer, F.4
-
4
-
-
0028073911
-
Migration of corrosion products from modular hip prostheses: Particle microanalysis and histopathological findings
-
Urban RM, Jacobs JJ, Gilbert JL, Galante JO. Migration of corrosion products from modular hip prostheses: Particle microanalysis and histopathological findings. J Bone Joint Surg 1994;76A:1345-1359.
-
(1994)
J Bone Joint Surg
, vol.76 A
, pp. 1345-1359
-
-
Urban, R.M.1
Jacobs, J.J.2
Gilbert, J.L.3
Galante, J.O.4
-
5
-
-
0031051493
-
Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements
-
Lee SH et al. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements. J Orthop Res 1997;15:40-49.
-
(1997)
J Orthop Res
, vol.15
, pp. 40-49
-
-
Lee, S.H.1
-
6
-
-
0028343874
-
Intergranular corrosion fatigue failure of cobalt alloy stems
-
Gilbert JL, Buckley CA, Jacobs JJ, Bertin KC, Zemich MR. Intergranular corrosion fatigue failure of cobalt alloy stems. J Bone Joint Surg 1994;76A:110-115.
-
(1994)
J Bone Joint Surg
, vol.76 A
, pp. 110-115
-
-
Gilbert, J.L.1
Buckley, C.A.2
Jacobs, J.J.3
Bertin, K.C.4
Zemich, M.R.5
-
7
-
-
0028887584
-
The tradeoffs associated with modular hip prostheses
-
Collier JP et al. The tradeoffs associated with modular hip prostheses. Clin Orthop 1995;311:91-101.
-
(1995)
Clin Orthop
, vol.311
, pp. 91-101
-
-
Collier, J.P.1
-
8
-
-
0025013478
-
Fretting corrosion studies of universal femoral head prostheses and cone taper spigots
-
Fricker DC, Shavanath R. Fretting corrosion studies of universal femoral head prostheses and cone taper spigots. Biomaterials 1990;11:495-500.
-
(1990)
Biomaterials
, vol.11
, pp. 495-500
-
-
Fricker, D.C.1
Shavanath, R.2
-
10
-
-
0344231032
-
Fretting at the head/neck interface of modular hip prostheses
-
Berlin
-
Dujovne AR, Bobyn JD, Krygier JJ, Wilson DR, Brooks CE. Fretting at the head/neck interface of modular hip prostheses. Fourth World Biomaterials Conference, Berlin; 1992. p 264.
-
(1992)
Fourth World Biomaterials Conference
, pp. 264
-
-
Dujovne, A.R.1
Bobyn, J.D.2
Krygier, J.J.3
Wilson, D.R.4
Brooks, C.E.5
-
11
-
-
0028272549
-
Characterization and quantification of fretting particulates generated in ceramic/metal and metal/metal modular head/taper systems
-
Kambic HE, Tokobori AT, editors. Philadelphia: American Society for Testing and Materials
-
Bhambri SK, Gilbertson LN. Characterization and quantification of fretting particulates generated in ceramic/metal and metal/metal modular head/taper systems. In Kambic HE, Tokobori AT, editors. Biomaterials' mechanical properties, ASTM STP 1173. Philadelphia: American Society for Testing and Materials; 1994. pp 111-126.
-
(1994)
Biomaterials' Mechanical Properties, ASTM STP 1173
, pp. 111-126
-
-
Bhambri, S.K.1
Gilbertson, L.N.2
-
12
-
-
0028259816
-
Mechanical testing for fretting corrosion of modular total hip tapers
-
Kambic HE, Tokobori AT, editors Philadelphia: American Society for Testing and Materials
-
Fleming CAC, Brown SA, Payer JH. Mechanical testing for fretting corrosion of modular total hip tapers. In Kambic HE, Tokobori AT, editors Biomaterials' mechanical properties, ASTM STP 1173. Philadelphia: American Society for Testing and Materials; 1994. p 156-166.
-
(1994)
Biomaterials' Mechanical Properties, ASTM STP 1173
, pp. 156-166
-
-
Fleming, C.A.C.1
Brown, S.A.2
Payer, J.H.3
-
13
-
-
0028054956
-
Wear and corrosion of modular interfaces in total hip replacements
-
Cook SD et al. Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop 1994;298:80-88.
-
(1994)
Clin Orthop
, vol.298
, pp. 80-88
-
-
Cook, S.D.1
-
14
-
-
0028057541
-
Wear debris: An environmental issue in total joint replacement
-
Manley MT, Serekian P. Wear debris: An environmental issue in total joint replacement. Clin Orthop 1994;298:137-146.
-
(1994)
Clin Orthop
, vol.298
, pp. 137-146
-
-
Manley, M.T.1
Serekian, P.2
-
15
-
-
0029257098
-
Fretting corrosion accelerates crevice corrosion of modular hip tapers
-
Brown SA et al. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 1995;6:19-26.
-
(1995)
J Appl Biomater
, vol.6
, pp. 19-26
-
-
Brown, S.A.1
-
19
-
-
5544297899
-
The mechanical and electrochemical processes associated with taper fretting crevice corrosion: A review
-
Marlowe DE, Parr JE, Mayor MB, editors. West Conshohocken, PA: American Society for Testing and Materials
-
Gilbert JL, Jacobs JJ. The mechanical and electrochemical processes associated with taper fretting crevice corrosion: A review. In Marlowe DE, Parr JE, Mayor MB, editors. Modularity of orthopedic implants, ASTM STP 1301. West Conshohocken, PA: American Society for Testing and Materials; 1997. p 45-59.
-
(1997)
Modularity of Orthopedic Implants, ASTM STP 1301
, pp. 45-59
-
-
Gilbert, J.L.1
Jacobs, J.J.2
-
20
-
-
0345093168
-
Test method for the assessment of fretting at the femoral head and neck taper interface
-
Marlowe DE, Parr JE, Mayor MB, editors. West Conshohocken, PA: American Society for Testing and Materials
-
McLean TW, Lambert RD. Test method for the assessment of fretting at the femoral head and neck taper interface. In Marlowe DE, Parr JE, Mayor MB, editors. Modularity of orthopedic implants, ASTM STP 1301. West Conshohocken, PA: American Society for Testing and Materials; 1997. p 104-113.
-
(1997)
Modularity of Orthopedic Implants, ASTM STP 1301
, pp. 104-113
-
-
McLean, T.W.1
Lambert, R.D.2
-
21
-
-
0345093169
-
Fretting corrosion fatigue study of modular joints in total hip replacements by accelerated in-vitro testing
-
Marlowe DE, Parr JE, Mayor MB, editors. West Conshohocken, PA: American Society for Testing and Materials
-
Bhambri SK, Gilbertson LN. Fretting corrosion fatigue study of modular joints in total hip replacements by accelerated in-vitro testing. In Marlowe DE, Parr JE, Mayor MB, editors. Modularity of orthopedic implants, ASTM STP 1301. West Conshohocken, PA: American Society for Testing and Materials; 1997. p 146-156.
-
(1997)
Modularity of Orthopedic Implants, ASTM STP 1301
, pp. 146-156
-
-
Bhambri, S.K.1
Gilbertson, L.N.2
-
22
-
-
0344662245
-
Fretting corrosion mechanisms at modular hip implant interfaces
-
Marlowe DE, Parr JE, Mayor MB, eds. West Conshohocken, PA: American Society for Testing and Materials
-
Jani SC, Sauer WL, McLean TW, Lambert RD, Kovacs P. Fretting corrosion mechanisms at modular hip implant interfaces. In Marlowe DE, Parr JE, Mayor MB, eds. Modularity of Orthopedic Implants, ASTM STP 1301. West Conshohocken, PA: American Society for Testing and Materials; 1997. p 211-225.
-
(1997)
Modularity of Orthopedic Implants, ASTM STP 1301
, pp. 211-225
-
-
Jani, S.C.1
Sauer, W.L.2
McLean, T.W.3
Lambert, R.D.4
Kovacs, P.5
-
23
-
-
0009912212
-
Corrosion testing of modular hip implants
-
Marlowe DE, Parr JE, Mayor MB, editors. West Conshohocken, PA: American Society of Testing and Materials
-
Goldberg JR, Buckley CA, Jacobs JJ, Gilbert JL. Corrosion testing of modular hip implants. In Marlowe DE, Parr JE, Mayor MB, editors. Modularity of orthopedic implants, ASTM STP 1301. West Conshohocken, PA: American Society of Testing and Materials; 1997. p 157-176.
-
(1997)
Modularity of Orthopedic Implants, ASTM STP 1301
, pp. 157-176
-
-
Goldberg, J.R.1
Buckley, C.A.2
Jacobs, J.J.3
Gilbert, J.L.4
-
25
-
-
0042035943
-
Mechanical-electrochemical interactions during in-vitro fretting corrosion tests of modular taper connections
-
Galante JO, Rosenberg AG, Callachan JJ, eds. New York: Raven Press
-
Gilbert JL, Buckley CA. Mechanical-electrochemical interactions during in-vitro fretting corrosion tests of modular taper connections. In Galante JO, Rosenberg AG, Callachan JJ, eds, Total hip revision surgery. New York: Raven Press; 1995. p 41-50.
-
(1995)
Total Hip Revision Surgery
, pp. 41-50
-
-
Gilbert, J.L.1
Buckley, C.A.2
-
27
-
-
0014746120
-
Abduction forces in the one-legged stance
-
McLeish RD, Charnley J. Abduction forces in the one-legged stance. J Biomech 1870;3:191-209.
-
(1870)
J Biomech
, vol.3
, pp. 191-209
-
-
McLeish, R.D.1
Charnley, J.2
-
28
-
-
0003113292
-
Bioengineering study of the forces transmitted by joints (II). Engineering analysis
-
Kenedi RM, editors. Oxford: Pergamon Press
-
Paul JP. Bioengineering study of the forces transmitted by joints (II). Engineering analysis. In Kenedi RM, editors. Biomechanics and related bioengineering topics. Oxford: Pergamon Press; 1965. p 369-380.
-
(1965)
Biomechanics and Related Bioengineering Topics
, pp. 369-380
-
-
Paul, J.P.1
-
29
-
-
33745561323
-
Load actions on the human femur in walking and some resultant stresses
-
Paul JP. Load actions on the human femur in walking and some resultant stresses. Exp Mech 1971;11:121-125.
-
(1971)
Exp Mech
, vol.11
, pp. 121-125
-
-
Paul, J.P.1
-
30
-
-
0016695470
-
Forces transmitted at the hip and knee joint of normal and disabled persons during a range of activities
-
Paul JP, McGrouther DA. Forces transmitted at the hip and knee joint of normal and disabled persons during a range of activities. Acta Orthop Belg 1975;41:78-88.
-
(1975)
Acta Orthop Belg
, vol.41
, pp. 78-88
-
-
Paul, J.P.1
McGrouther, D.A.2
-
31
-
-
0011257604
-
A force analysis of the hip joint
-
Williams JF, Svensson NL. A force analysis of the hip joint. Biomed Eng 1968;3:365-370.
-
(1968)
Biomed Eng
, vol.3
, pp. 365-370
-
-
Williams, J.F.1
Svensson, N.L.2
-
32
-
-
0018616928
-
In-vivo records of hip loads using a femoral implant with telemetric output (A preliminary report)
-
English TA, Kilvington M. In-vivo records of hip loads using a femoral implant with telemetric output (A preliminary report). J Biomed Eng 1979;1:111-115.
-
(1979)
J Biomed Eng
, vol.1
, pp. 111-115
-
-
English, T.A.1
Kilvington, M.2
-
33
-
-
0023869835
-
Telemetric force measurements across the hip after total arthroplasty
-
Davy DT et al. Telemetric force measurements across the hip after total arthroplasty. J Bone Joint Surg 1988;70:45-50.
-
(1988)
J Bone Joint Surg
, vol.70
, pp. 45-50
-
-
Davy, D.T.1
-
34
-
-
0013873902
-
Forces acting on the femoral head prosthesis: A study on strain gage supplied prostheses in living persons
-
Rydell NW. Forces acting on the femoral head prosthesis: A study on strain gage supplied prostheses in living persons. Acta Orthop Scand 1966;37(Suppl88):1-132.
-
(1966)
Acta Orthop Scand
, vol.37
, Issue.SUPPL. 88
, pp. 1-132
-
-
Rydell, N.W.1
-
35
-
-
0030143195
-
Titanium oxide film fracture and repassivation: The effect of potential, pH, and aeration
-
Brown SA, Lemons JE, editors. Philadelphia: American Society for Testing and Materials
-
Gilbert JL, Buckley CA, Lautenschlager EP. Titanium oxide film fracture and repassivation: The effect of potential, pH, and aeration. In Brown SA, Lemons JE, editors. Medical applications of titanium and its alloys: The materials and biological issues, ASTM STP 1272. Philadelphia: American Society for Testing and Materials; 1996. p 199-215.
-
(1996)
Medical Applications of Titanium and Its Alloys: The Materials and Biological Issues, ASTM STP 1272
, pp. 199-215
-
-
Gilbert, J.L.1
Buckley, C.A.2
Lautenschlager, E.P.3
-
36
-
-
0031555492
-
Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method
-
Goldberg JR, Gilbert JL. Electrochemical response of CoCrMo to high speed fracture of its metal oxide using an electrochemical scratch test method. J Biomed Mater Res 1997;37:421-431.
-
(1997)
J Biomed Mater Res
, vol.37
, pp. 421-431
-
-
Goldberg, J.R.1
Gilbert, J.L.2
-
37
-
-
0029377434
-
A clearer view of how crevice corrosion occurs
-
De Force B, Pickering H. A clearer view of how crevice corrosion occurs. J Metals 1995;22-27.
-
(1995)
J Metals
, pp. 22-27
-
-
De Force, B.1
Pickering, H.2
-
38
-
-
0345093164
-
Fretting corrosion of Ti-6A1-4V reveals two fretting regimes
-
Smith BJ, Ducheyne P. Fretting corrosion of Ti-6A1-4V reveals two fretting regimes. Trans Soc Biomater 1994;17:265.
-
(1994)
Trans Soc Biomater
, vol.17
, pp. 265
-
-
Smith, B.J.1
Ducheyne, P.2
-
39
-
-
51249172362
-
Material effects in fretting wear: Application to iron, titanium, and aluminum alloys
-
Blanchard P, Colombie C, Pellerin V, Fayeulle S, Vincent L. Material effects in fretting wear: Application to iron, titanium, and aluminum alloys. Metallurgical Trans 1991;22A:1535-1544.
-
(1991)
Metallurgical Trans
, vol.22 A
, pp. 1535-1544
-
-
Blanchard, P.1
Colombie, C.2
Pellerin, V.3
Fayeulle, S.4
Vincent, L.5
|