메뉴 건너뛰기




Volumn 64, Issue 2, 2003, Pages 99-106

Surface Composition Analysis of Failed Cementless CoCr- and Ti-Base-Alloy Total Hip Implants

Author keywords

Arthroplasty; EDX; Hip; SEM; XPS

Indexed keywords

BONE CEMENT; IMPLANTS (SURGICAL); SCANNING ELECTRON MICROSCOPY; TITANIUM ALLOYS; X RAY ANALYSIS; X RAY PHOTOELECTRON SPECTROSCOPY;

EID: 0345169006     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.10555     Document Type: Article
Times cited : (13)

References (26)
  • 4
    • 0035255416 scopus 로고    scopus 로고
    • Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces
    • Schmidt C, Ignatius AA, Claes LE. Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces. J Biomed Mater Res 2001;54:209-215.
    • (2001) J Biomed Mater Res , vol.54 , pp. 209-215
    • Schmidt, C.1    Ignatius, A.A.2    Claes, L.E.3
  • 5
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - A materials science perspective
    • Long M, Rack HJ. Titanium alloys in total joint replacement-A materials science perspective. Biomaterials 1998;19:1621-1639.
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 6
    • 0035869773 scopus 로고    scopus 로고
    • Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion
    • Koerten HK, Onderwater JJM, Koerten EWA, Bernoski FP, Nelissen RGHH. Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion. J Biomed Mater Res 2000;54:591-596.
    • (2000) J Biomed Mater Res , vol.54 , pp. 591-596
    • Koerten, H.K.1    Onderwater, J.J.M.2    Koerten, E.W.A.3    Bernoski, F.P.4    Nelissen, R.G.H.H.5
  • 7
    • 0031864958 scopus 로고    scopus 로고
    • In vivo corrosion of 316L stainless-steel hip implants: Morphology and elemental compositions of corrosion products
    • Walczak J, Shahgaldi F, Heatley F. In vivo corrosion of 316L stainless-steel hip implants: Morphology and elemental compositions of corrosion products. Biomaterials 1998;19:229-237.
    • (1998) Biomaterials , vol.19 , pp. 229-237
    • Walczak, J.1    Shahgaldi, F.2    Heatley, F.3
  • 9
    • 0001176746 scopus 로고
    • Embedded particulate contaminants in textured metal implant surfaces: Technical Note
    • Ricci JL, Kummer FJ, Alexander H, Cesar RS. Embedded particulate contaminants in textured metal implant surfaces: Technical Note. J Appl Biomater 1992;3:225-230.
    • (1992) J Appl Biomater , vol.3 , pp. 225-230
    • Ricci, J.L.1    Kummer, F.J.2    Alexander, H.3    Cesar, R.S.4
  • 11
    • 0029850587 scopus 로고    scopus 로고
    • Long-term clinical and radiological results of the Lord total hip prosthesis. A prospective study
    • Malchau H, Herberts P, Wang YX, Karrholm J, Romanus B. Long-term clinical and radiological results of the Lord total hip prosthesis. A prospective study. J Bone Joint Surg Br 1996;78:884-891.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 884-891
    • Malchau, H.1    Herberts, P.2    Wang, Y.X.3    Karrholm, J.4    Romanus, B.5
  • 14
    • 0023741339 scopus 로고
    • Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report
    • Svensson O, Mathiesen EB, Reinholt FP, Blomgren G. Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report. J Bone Joint Surg Am 1988;70:1238-1242.
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 1238-1242
    • Svensson, O.1    Mathiesen, E.B.2    Reinholt, F.P.3    Blomgren, G.4
  • 16
    • 0029774258 scopus 로고    scopus 로고
    • Aluminium toxicity: Its relationship with bone and mineral metabolism
    • Cannata Andia JB. Aluminium toxicity: its relationship with bone and mineral metabolism. Nephrol Dial Transplant 1996;11(Suppl 3):69-73.
    • (1996) Nephrol Dial Transplant , vol.11 , Issue.SUPPL. 3 , pp. 69-73
    • Cannata Andia, J.B.1
  • 17
    • 0031717596 scopus 로고    scopus 로고
    • Migration and failure of the Mecron screw-in acetabular prosthesis
    • Chell J, Howard PW. Migration and failure of the Mecron screw-in acetabular prosthesis. J Arthroplasty 1998;13:638-641.
    • (1998) J Arthroplasty , vol.13 , pp. 638-641
    • Chell, J.1    Howard, P.W.2
  • 22
    • 0032171419 scopus 로고    scopus 로고
    • Analysis of titanium dental implants after failure of osseointegration: Combined histological, electron microscopy, and x-ray photoelectron spectroscopy approach
    • Arys A, Philippart C, Dourov N, He Y, Le QT, Pireaux JJ. Analysis of titanium dental implants after failure of osseointegration: Combined histological, electron microscopy, and x-ray photoelectron spectroscopy approach. J Biomed Mater Res 1998;43:300-312.
    • (1998) J Biomed Mater Res , vol.43 , pp. 300-312
    • Arys, A.1    Philippart, C.2    Dourov, N.3    He, Y.4    Le, Q.T.5    Pireaux, J.J.6
  • 23
    • 0027654197 scopus 로고
    • The surface analysis of implant materials. 1. The surface composition of a titanium dental implant material
    • Ameen AP, Short RD, Johns R, Schwach G. The surface analysis of implant materials. 1. The surface composition of a titanium dental implant material. Clin Oral Implants Res 1993;4:144-150.
    • (1993) Clin Oral Implants Res , vol.4 , pp. 144-150
    • Ameen, A.P.1    Short, R.D.2    Johns, R.3    Schwach, G.4
  • 24
    • 0032213426 scopus 로고    scopus 로고
    • Characterization of the properties of differently modified titanium surfaces for dental implantology. 1: Methods for surface analysis
    • Liefeith K, Sauberlich S, Frant M, Klee D, Richter EJ, Hocker H, Spiekermann H. Characterization of the properties of differently modified titanium surfaces for dental implantology. 1: Methods for surface analysis. Biomed Tech (Berl) 1998;43:330-335.
    • (1998) Biomed Tech (Berl) , vol.43 , pp. 330-335
    • Liefeith, K.1    Sauberlich, S.2    Frant, M.3    Klee, D.4    Richter, E.J.5    Hocker, H.6    Spiekermann, H.7
  • 25
    • 0035811287 scopus 로고    scopus 로고
    • Surface modification of titanium through amino group implantation
    • Yang YZ, Tian JM, Tian JT, Chen ZQ. Surface modification of titanium through amino group implantation. J Biomed Mater Res 2001;55:442-444.
    • (2001) J Biomed Mater Res , vol.55 , pp. 442-444
    • Yang, Y.Z.1    Tian, J.M.2    Tian, J.T.3    Chen, Z.Q.4
  • 26
    • 0023805329 scopus 로고
    • Biomaterial and implant surfaces: On the role of cleanliness, contamination, and preparation procedures
    • Kasemo B, Lausmaa J. Biomaterial and implant surfaces: On the role of cleanliness, contamination, and preparation procedures. J Biomed Mater Res 1988;22:145-158.
    • (1988) J Biomed Mater Res , vol.22 , pp. 145-158
    • Kasemo, B.1    Lausmaa, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.