메뉴 건너뛰기




Volumn 41, Issue 3, 1999, Pages 563-568

A strategy to optimize the signal-to-noise ratio in one-coil arterial spin tagging perfusion imaging

Author keywords

Arterial spin tagging; Cerebral perfusion; MR perfusion imaging

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; IMAGE PROCESSING; MAGNETIC RESONANCE;

EID: 0344629266     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199903)41:3<563::AID-MRM20>3.0.CO;2-6     Document Type: Article
Times cited : (15)

References (34)
  • 1
    • 0028961859 scopus 로고
    • NMR measurement of perfusion using arterial spin labeling without saturation of macromolocular spins
    • Zhang W, Silva AC, Williams DS, Koretsky AP. NMR measurement of perfusion using arterial spin labeling without saturation of macromolocular spins. Magn Reson Med 1935;33:370-376.
    • (1935) Magn Reson Med , vol.33 , pp. 370-376
    • Zhang, W.1    Silva, A.C.2    Williams, D.S.3    Koretsky, A.P.4
  • 2
    • 0028854355 scopus 로고
    • Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling
    • Silva AC, Zhang W, Williams DS, Koretsky AP. Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling. Magn Reson Med 1995;33:209-214.
    • (1995) Magn Reson Med , vol.33 , pp. 209-214
    • Silva, A.C.1    Zhang, W.2    Williams, D.S.3    Koretsky, A.P.4
  • 5
    • 0027283766 scopus 로고
    • Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water
    • Williams DS, Grandis DJ, Zhang W, Koretsky AP. Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water. Magn Reson Med 1993;30:361-365.
    • (1993) Magn Reson Med , vol.30 , pp. 361-365
    • Williams, D.S.1    Grandis, D.J.2    Zhang, W.3    Koretsky, A.P.4
  • 9
    • 0029353626 scopus 로고
    • Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-lorentzian lineshape and dipolar reservoir
    • Morrison C, Stanisz G, Henkelman RM. Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir. J Magn Reson B 1995;108:103-113.
    • (1995) J Magn Reson B , vol.108 , pp. 103-113
    • Morrison, C.1    Stanisz, G.2    Henkelman, R.M.3
  • 11
    • 0028323068 scopus 로고
    • Determination of proton magnetization transfer rate constants in heterogeneous biological systems
    • Brooks D, Kuwata K, Schleich T. Determination of proton magnetization transfer rate constants in heterogeneous biological systems. Magn Reson Med 1994;31:331-336.
    • (1994) Magn Reson Med , vol.31 , pp. 331-336
    • Brooks, D.1    Kuwata, K.2    Schleich, T.3
  • 12
    • 0030962529 scopus 로고    scopus 로고
    • Effect of magnetization transfer on the measurement of cerebral blood flow using steady-state arterial spin tagging approaches: A theoretical investigation
    • McLaughlin AC, Ye FQ, Pekar JJ, Santha AK, Frank JA. Effect of magnetization transfer on the measurement of cerebral blood flow using steady-state arterial spin tagging approaches: a theoretical investigation. Magn Reson Med 1997;37:501-510.
    • (1997) Magn Reson Med , vol.37 , pp. 501-510
    • McLaughlin, A.C.1    Ye, F.Q.2    Pekar, J.J.3    Santha, A.K.4    Frank, J.A.5
  • 13
    • 0030203923 scopus 로고    scopus 로고
    • Perfusion imaging of the human brain at 1.5 T using a single-shot EPI spin tagging approach
    • Ye FQ, Pekar JJ, Jezzard P. Duyn J, Frank JA, McLaughlin AC. Perfusion imaging of the human brain at 1.5 T using a single-shot EPI spin tagging approach. Magn Reson Med 1996;36:217-224.
    • (1996) Magn Reson Med , vol.36 , pp. 217-224
    • Ye, F.Q.1    Pekar, J.J.2    Jezzard, P.3    Duyn, J.4    Frank, J.A.5    McLaughlin, A.C.6
  • 14
    • 0028014523 scopus 로고
    • Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water
    • Roberts DA, Detre JA, Bolinger L, Insko EK, Leigh JS. Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. Proc Natl Acad Sci USA 1994;91:33-37.
    • (1994) Proc Natl Acad Sci USA , vol.91 , pp. 33-37
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3    Insko, E.K.4    Leigh, J.S.5
  • 16
    • 0031032547 scopus 로고    scopus 로고
    • Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling
    • Silva AC, Zhang W, Williams DS, Koretsky AP. Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling. Magn Reson Med 1997;35:58-68.
    • (1997) Magn Reson Med , vol.35 , pp. 58-68
    • Silva, A.C.1    Zhang, W.2    Williams, D.S.3    Koretsky, A.P.4
  • 17
    • 0027474297 scopus 로고
    • Measurement of rat brain perfusion by NMR using spin labeling of arterial water: In vivo determination of the degree of spin labeling
    • Zhang W, Williams DS, Koretsky AP. Measurement of rat brain perfusion by NMR using spin labeling of arterial water: in vivo determination of the degree of spin labeling. Magn Reson Med 1993;29:416-421.
    • (1993) Magn Reson Med , vol.29 , pp. 416-421
    • Zhang, W.1    Williams, D.S.2    Koretsky, A.P.3
  • 18
  • 19
    • 0020073799 scopus 로고
    • Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field
    • Thulborn KR, Waterton JC, Mathews PM, Radda G. Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim Biophvs Acta 1982;714:265-270.
    • (1982) Biochim Biophvs Acta , vol.714 , pp. 265-270
    • Thulborn, K.R.1    Waterton, J.C.2    Mathews, P.M.3    Radda, G.4
  • 20
    • 45949114306 scopus 로고
    • Localized proton spectroscopy using stimulated echoes
    • Frahm K, Merboldt D, Hanicke W. Localized proton spectroscopy using stimulated echoes. J Magn Reson 1987;72:502-508.
    • (1987) J Magn Reson , vol.72 , pp. 502-508
    • Frahm, K.1    Merboldt, D.2    Hanicke, W.3
  • 21
    • 0026534203 scopus 로고
    • Scan time reduction in snapshot FLASH MRI
    • Jakob PM, Haase A. Scan time reduction in snapshot FLASH MRI. Magn Reson Med 1992;24:391-396.
    • (1992) Magn Reson Med , vol.24 , pp. 391-396
    • Jakob, P.M.1    Haase, A.2
  • 22
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996;16:1236-1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 23
    • 0030090684 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the brain:Blood partition coefficient for water: Application to spin-tagging measurement of perfusion
    • Roberts DA, Rizi R, Lenkinski RE, Leigh JS. Magnetic resonance imaging of the brain:blood partition coefficient for water: application to spin-tagging measurement of perfusion. J Magn Reson Imaging 1996;6:363-366.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 363-366
    • Roberts, D.A.1    Rizi, R.2    Lenkinski, R.E.3    Leigh, J.S.4
  • 24
    • 0030012099 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice
    • Schwarzbauer C, Morrissey SP, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice. Magn Reson Med 1996;35:540-546.
    • (1996) Magn Reson Med , vol.35 , pp. 540-546
    • Schwarzbauer, C.1    Morrissey, S.P.2    Haase, A.3
  • 25
    • 0024442827 scopus 로고
    • Effects of nitrous oxide and volatile anaesthetics on cerebral blood flow
    • Hansen TD, Warner DS, Todd MM, Vust LJ. Effects of nitrous oxide and volatile anaesthetics on cerebral blood flow. Br J Anaesth 1989;63:290-295.
    • (1989) Br J Anaesth , vol.63 , pp. 290-295
    • Hansen, T.D.1    Warner, D.S.2    Todd, M.M.3    Vust, L.J.4
  • 26
    • 0021087648 scopus 로고
    • Regional differences in vascular autoregulation in the rat brain in severe insulin-induced hypoglycemia
    • Siesjo BK, Ingvar M, Pelligrino D. Regional differences in vascular autoregulation in the rat brain in severe insulin-induced hypoglycemia. J Cereb Blood Flow Metab 1983;3:478-485.
    • (1983) J Cereb Blood Flow Metab , vol.3 , pp. 478-485
    • Siesjo, B.K.1    Ingvar, M.2    Pelligrino, D.3
  • 27
    • 0017744474 scopus 로고
    • Cerebral blood flow and oxygen consumption in rat, measured with microspheres or xenon
    • Gjedde A, de la Monte SM, Caronna JJ. Cerebral blood flow and oxygen consumption in rat, measured with microspheres or xenon. Acta Physiol Scand 1977;100:273-281.
    • (1977) Acta Physiol Scand , vol.100 , pp. 273-281
    • Gjedde, A.1    De La Monte, S.M.2    Caronna, J.J.3
  • 28
    • 0030828060 scopus 로고    scopus 로고
    • Regional cerebral blood flow during and after 2 hours of middle cerebral artery occlusion in the rat
    • Tsuchidate R, He QP, Smith ML, Siesjo BK. Regional cerebral blood flow during and after 2 hours of middle cerebral artery occlusion in the rat. J Cereb Blood Flow Metab 1997;17:1066-1073.
    • (1997) J Cereb Blood Flow Metab , vol.17 , pp. 1066-1073
    • Tsuchidate, R.1    He, Q.P.2    Smith, M.L.3    Siesjo, B.K.4
  • 31
    • 0022490282 scopus 로고
    • Continueous measurement of cerebral blood volume in rats with the photoelectric technique: Effect of morphine and naloxone
    • Sandor P, Cox-van Put J, de Jong W, de Wied D. Continueous measurement of cerebral blood volume in rats with the photoelectric technique: effect of morphine and naloxone. Life Sci 1986;39:1657-1665.
    • (1986) Life Sci , vol.39 , pp. 1657-1665
    • Sandor, P.1    Cox-Van Put, J.2    De Jong, W.3    De Wied, D.4
  • 32
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC. Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn Reson Med 1997;37:226-235.
    • (1997) Magn Reson Med , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6
  • 33
    • 0030086467 scopus 로고    scopus 로고
    • Ultrafast perfusion-weighted MRI of functional brain activiation in rats during forepaw stimulation: Comparison with T2*-weighted MRI
    • Kerskens CM, Hoehn-Berlage M, Schmitz B, Busch E, Bock C, Gyngell ML, Hossmann KA. Ultrafast perfusion-weighted MRI of functional brain activiation in rats during forepaw stimulation: comparison with T2*-weighted MRI. NMR Biomed 1996;8:20-23.
    • (1996) NMR Biomed , vol.8 , pp. 20-23
    • Kerskens, C.M.1    Hoehn-Berlage, M.2    Schmitz, B.3    Busch, E.4    Bock, C.5    Gyngell, M.L.6    Hossmann, K.A.7
  • 34
    • 0026877346 scopus 로고
    • Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: Accounting for transit time and cross-relaxation
    • Zhang W. Williams DS, Detre JA, Koretsky AP. Measurement of brain perfusion by volume-localized NMR spectroscopy using inversion of arterial water spins: accounting for transit time and cross-relaxation. Magn Reson Med 1992;25:362-371.
    • (1992) Magn Reson Med , vol.25 , pp. 362-371
    • Zhang, W.1    Williams, D.S.2    Detre, J.A.3    Koretsky, A.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.