-
1
-
-
0027503994
-
Lessons from intravascular ultrasonography: Observations during interventional angioplasty procedures
-
Tobis JM, Mahon DJ, Goldberg SL, Nakamura S, Colombo A. Lessons from intravascular ultrasonography: Observations during interventional angioplasty procedures. J Clin Ultrasound 1993; 21(9):589-607.
-
(1993)
J Clin Ultrasound
, vol.21
, Issue.9
, pp. 589-607
-
-
Tobis, J.M.1
Mahon, D.J.2
Goldberg, S.L.3
Nakamura, S.4
Colombo, A.5
-
2
-
-
0030785467
-
Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions
-
Hoffmann R, Mintz GS, Popma JJ, et al. Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions. Am J Cardiol 1997; 80(10): 1277-1281.
-
(1997)
Am J Cardiol
, vol.80
, Issue.10
, pp. 1277-1281
-
-
Hoffmann, R.1
Mintz, G.S.2
Popma, J.J.3
-
3
-
-
0345563276
-
Relation of angiographic and ultrasound assessment of plaque progression to clinical outcomes
-
Weintraub WS. Relation of angiographic and ultrasound assessment of plaque progression to clinical outcomes. Am J Cardiol 1998; 81(8A): 69F-72F.
-
(1998)
Am J Cardiol
, vol.81
, Issue.8 A
-
-
Weintraub, W.S.1
-
4
-
-
0032516437
-
Mechanisms of residual lumen stenosis after high-pressure stent implantation: A quantitative coronary angiography and intravascular ultrasound study
-
Bermejo J, Botas J, Garcia E, et al. Mechanisms of residual lumen stenosis after high-pressure stent implantation: A quantitative coronary angiography and intravascular ultrasound study. Circulation 1998; 98(2): 112-118.
-
(1998)
Circulation
, vol.98
, Issue.2
, pp. 112-118
-
-
Bermejo, J.1
Botas, J.2
Garcia, E.3
-
5
-
-
0033554444
-
Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study
-
Sabate M, Serruys PW, Van Der Giessen WJ, et al. Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study. Circulation 1999; 100(11): 1182-1188.
-
(1999)
Circulation
, vol.100
, Issue.11
, pp. 1182-1188
-
-
Sabate, M.1
Serruys, P.W.2
Van Der Giessen, W.J.3
-
6
-
-
0035970098
-
Intravascular ultrasound: Novel pathophysiological insights and current clinical applications
-
Nissen SE, Yock P. Intravascular ultrasound: Novel pathophysiological insights and current clinical applications. Circulation 2001; 103(4): 604-616.
-
(2001)
Circulation
, vol.103
, Issue.4
, pp. 604-616
-
-
Nissen, S.E.1
Yock, P.2
-
7
-
-
0029073780
-
Atherosclerosis in angiographically 'normal' coronary artery reference segments: An intravascular ultrasound study with clinical correlations
-
Mintz GS, Painter JA, Pichard AD, et al. Atherosclerosis in angiographically 'normal' coronary artery reference segments: An intravascular ultrasound study with clinical correlations. J Am Coll Cardiol 1995; 25(7): 1479-1485.
-
(1995)
J Am Coll Cardiol
, vol.25
, Issue.7
, pp. 1479-1485
-
-
Mintz, G.S.1
Painter, J.A.2
Pichard, A.D.3
-
8
-
-
0029893460
-
Angiographically silent atherosclerosis detected by intravascular ultrasound in patients with familial hypercholesterolemia and familial combined hyperlipidemia: Correlation with high density lipoproteins
-
Hausmann D, Johnson JA, Sudhir K, et al. Angiographically silent atherosclerosis detected by intravascular ultrasound in patients with familial hypercholesterolemia and familial combined hyperlipidemia: Correlation with high density lipoproteins. J Am Coll Cardiol 1996; 27(7): 1562-1570.
-
(1996)
J Am Coll Cardiol
, vol.27
, Issue.7
, pp. 1562-1570
-
-
Hausmann, D.1
Johnson, J.A.2
Sudhir, K.3
-
9
-
-
0030842525
-
Intravascular ultrasound assessment of the prevalence and causes of angiographic 'haziness' following high-pressure coronary stenting
-
Ziada KM, Tuzcu EM, De Franco AC, et al. Intravascular ultrasound assessment of the prevalence and causes of angiographic 'haziness' following high-pressure coronary stenting. J Am Cardiol 1997; 80(2): 116-121.
-
(1997)
J Am Cardiol
, vol.80
, Issue.2
, pp. 116-121
-
-
Ziada, K.M.1
Tuzcu, E.M.2
De Franco, A.C.3
-
10
-
-
0035822684
-
Lumen loss in transplant coronary artery disease is a biphasic process involving early intimal thickening and late constrictive remodeling: Results from a 5-year intravascular ultrasound study
-
Tsutsui H, Ziada KM, Schoenhagen P, et al. Lumen loss in transplant coronary artery disease is a biphasic process involving early intimal thickening and late constrictive remodeling: Results from a 5-year intravascular ultrasound study. Circulation 2001; 104(6): 653-657.
-
(2001)
Circulation
, vol.104
, Issue.6
, pp. 653-657
-
-
Tsutsui, H.1
Ziada, K.M.2
Schoenhagen, P.3
-
11
-
-
0032216603
-
Tissue characterization in intravascular ultrasound images
-
Zhang X, McKay CR, Sonka M. Tissue characterization in intravascular ultrasound images. IEEE Trans Med Imaging 1998; 17(6): 889-899.
-
(1998)
IEEE Trans Med Imaging
, vol.17
, Issue.6
, pp. 889-899
-
-
Zhang, X.1
McKay, C.R.2
Sonka, M.3
-
12
-
-
0034014945
-
Segmentation of 3D intravascular ultrasonic images based on a random field model
-
Haas C, Emert H, Holt S, Grewe P, Machraoui A, Barmeyer J. Segmentation of 3D intravascular ultrasonic images based on a random field model. Ultrasound Med Biol 2000; 26(2): 297-306.
-
(2000)
Ultrasound Med Biol
, vol.26
, Issue.2
, pp. 297-306
-
-
Haas, C.1
Emert, H.2
Holt, S.3
Grewe, P.4
Machraoui, A.5
Barmeyer, J.6
-
13
-
-
0029962637
-
Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque
-
Von Birgelen C, Di Mario C, Li W, et al. Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque. Am Heart J 1996; 132(3): 516-527.
-
(1996)
Am Heart J
, vol.132
, Issue.3
, pp. 516-527
-
-
Von Birgelen, C.1
Di Mario, C.2
Li, W.3
-
14
-
-
0034076558
-
Three-dimensional automatic quantitative analysis of intravascular ultrasound images
-
Kovalski G, Beyar R, Shofti R, Azhari H. Three-dimensional automatic quantitative analysis of intravascular ultrasound images. Ultrasound Med Biol 2000; 26(4): 527-537.
-
(2000)
Ultrasound Med Biol
, vol.26
, Issue.4
, pp. 527-537
-
-
Kovalski, G.1
Beyar, R.2
Shofti, R.3
Azhari, H.4
-
15
-
-
0021931822
-
Limitations of postmortem assessment of human coronary artery size and luminal narrowing: Differential effects of tissue fixation and processing on vessels with different degrees of atherosclerosis
-
Siegel RJ, Swan K, Edwalds G, Fishbein MC. Limitations of postmortem assessment of human coronary artery size and luminal narrowing: Differential effects of tissue fixation and processing on vessels with different degrees of atherosclerosis. J Am Coll Cardiol 1985; 5(2 Pt 1): 342-346.
-
(1985)
J Am Coll Cardiol
, vol.5
, Issue.PART 1
, pp. 342-346
-
-
Siegel, R.J.1
Swan, K.2
Edwalds, G.3
Fishbein, M.C.4
-
16
-
-
0029856970
-
Reproducibility of quantitative measurements from intracoronary ultrasound images. Beat-to-beat variability and influence of the cardiac cycle
-
Peters RJG, Kok WEM, Rijsterborgh H, et al. Reproducibility of quantitative measurements from intracoronary ultrasound images. Beat-to-beat variability and influence of the cardiac cycle. Eur Heart J 1996; 17(10): 1593-1599.
-
(1996)
Eur Heart J
, vol.17
, Issue.10
, pp. 1593-1599
-
-
Peters, R.J.G.1
Kok, W.E.M.2
Rijsterborgh, H.3
-
17
-
-
0030751675
-
Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasound
-
Meier DS, Cothren RM, Vince DG, Cornhill JF. Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasound. Am Heart J 1997; 133(6): 681-690.
-
(1997)
Am Heart J
, vol.133
, Issue.6
, pp. 681-690
-
-
Meier, D.S.1
Cothren, R.M.2
Vince, D.G.3
Cornhill, J.F.4
-
18
-
-
0344241155
-
Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images
-
Shekhar R, Cothren RM, Vince DG, Chandra S, Thomas JD, Cornhill JF. Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images. Comput Med Imaging Graph 1999; 23(6): 299-309.
-
(1999)
Comput Med Imaging Graph
, vol.23
, Issue.6
, pp. 299-309
-
-
Shekhar, R.1
Cothren, R.M.2
Vince, D.G.3
Chandra, S.4
Thomas, J.D.5
Cornhill, J.F.6
-
19
-
-
0034287383
-
Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images
-
Klingensmith JD, Shekhar R, Vince DG. Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images. IEEE Trans Med Imaging 2000; 19(10): 996-1011.
-
(2000)
IEEE Trans Med Imaging
, vol.19
, Issue.10
, pp. 996-1011
-
-
Klingensmith, J.D.1
Shekhar, R.2
Vince, D.G.3
-
20
-
-
0017163375
-
Comparing the joint agreement of several raters with another rater
-
Williams GW. Comparing the joint agreement of several raters with another rater. Biometrics 1976; 32(3): 619-627.
-
(1976)
Biometrics
, vol.32
, Issue.3
, pp. 619-627
-
-
Williams, G.W.1
-
22
-
-
0031240184
-
A methodology for evaluation of boundary detection algorithms on medical images
-
Chalana V, Kim Y. A methodology for evaluation of boundary detection algorithms on medical images. IEEE Trans Med Imaging 1997; 16(5): 642-652.
-
(1997)
IEEE Trans Med Imaging
, vol.16
, Issue.5
, pp. 642-652
-
-
Chalana, V.1
Kim, Y.2
-
23
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310.
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
24
-
-
0031281755
-
Automatic segmentation of intravascular ultrasound images: A texture-based approach
-
Mojsilovic A, Popovic M, Amodaj N, Babic R, Ostojic M. Automatic segmentation of intravascular ultrasound images: A texture-based approach. Ann Biomed Eng 1997; 25(6): 1059-1071.
-
(1997)
Ann Biomed Eng
, vol.25
, Issue.6
, pp. 1059-1071
-
-
Mojsilovic, A.1
Popovic, M.2
Amodaj, N.3
Babic, R.4
Ostojic, M.5
-
25
-
-
0029481761
-
Segmentation of intravascular ultrasound images: A knowledge-based approach
-
Sonka M, Zhang X, Siebes M, Bissing MS, DeJong SC, Collins SM, et al. Segmentation of intravascular ultrasound images: A knowledge-based approach. IEEE Trans Med Imaging 1995; 14(4): 719-732.
-
(1995)
IEEE Trans Med Imaging
, vol.14
, Issue.4
, pp. 719-732
-
-
Sonka, M.1
Zhang, X.2
Siebes, M.3
Bissing, M.S.4
DeJong, S.C.5
Collins, S.M.6
-
26
-
-
0034233034
-
Automated contour detection for high-frequency intravascular ultrasound imaging: A technique with blood noise reduction for edge enhancement
-
Takagi A, Hibi K, Zhang X, Teo TJ, Bonneau HN, Yock PG, et al. Automated contour detection for high-frequency intravascular ultrasound imaging: A technique with blood noise reduction for edge enhancement. Ultrasound Med Biol 2000; 26(6): 1033-1041.
-
(2000)
Ultrasound Med Biol
, vol.26
, Issue.6
, pp. 1033-1041
-
-
Takagi, A.1
Hibi, K.2
Zhang, X.3
Teo, T.J.4
Bonneau, H.N.5
Yock, P.G.6
-
27
-
-
0031215698
-
Automated lumen definition from 30 MHz intravascular ultrasound images
-
Bouma CJ, Niessen WJ, Zuiderveld KJ, Gussenhoven EJ, Viergever MA. Automated lumen definition from 30 MHz intravascular ultrasound images. Med Image Anal 1997; 1(4): 363-377.
-
(1997)
Med Image Anal
, vol.1
, Issue.4
, pp. 363-377
-
-
Bouma, C.J.1
Niessen, W.J.2
Zuiderveld, K.J.3
Gussenhoven, E.J.4
Viergever, M.A.5
-
28
-
-
0031951361
-
Evaluation of an automatic intraluminal edge detection technique for intravascular ultrasound images
-
Finet G, Maurincomme E, Reiber JH, Savalle L, Magnin I, Beaune J. Evaluation of an automatic intraluminal edge detection technique for intravascular ultrasound images. Jpn Circ J 1998; 62(2): 115-121.
-
(1998)
Jpn Circ J
, vol.62
, Issue.2
, pp. 115-121
-
-
Finet, G.1
Maurincomme, E.2
Reiber, J.H.3
Savalle, L.4
Magnin, I.5
Beaune, J.6
-
29
-
-
0030330381
-
Computerized assessment of coronary lumen and atherosclerotic plaque dimensions in three-dimensional intravascular ultrasound correlated with histomorphometry
-
Von Birgelen C, Van Der Lugt A, Nicosia A, et al. Computerized assessment of coronary lumen and atherosclerotic plaque dimensions in three-dimensional intravascular ultrasound correlated with histomorphometry. Am J Cardiol 1996; 78(11): 1202-1209.
-
(1996)
Am J Cardiol
, vol.78
, Issue.11
, pp. 1202-1209
-
-
Von Birgelen, C.1
Van Der Lugt, A.2
Nicosia, A.3
-
30
-
-
0030671369
-
ECG-gated three-dimensional intravascular ultrasound: Feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans
-
Von Birgelen C, De Vrey EA, Mintz GS, et al. ECG-gated three-dimensional intravascular ultrasound: Feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans. Circulation 1997; 96(9): 2944-2952.
-
(1997)
Circulation
, vol.96
, Issue.9
, pp. 2944-2952
-
-
Von Birgelen, C.1
De Vrey, E.A.2
Mintz, G.S.3
-
31
-
-
0035943069
-
Use of intravascular ultrasound to compare effects of different strategies of lipid-lowering therapy on plaque volume and composition in patients with coronary artery disease
-
Schartl M, Bocksch W, Koschyk D, et al. Use of intravascular ultrasound to compare effects of different strategies of lipid-lowering therapy on plaque volume and composition in patients with coronary artery disease. Circulation 2001; 104(4): 387-392.
-
(2001)
Circulation
, vol.104
, Issue.4
, pp. 387-392
-
-
Schartl, M.1
Bocksch, W.2
Koschyk, D.3
-
32
-
-
17544396118
-
Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification
-
Von Birgelen C, Mintz GS, Nicosia A, et al. Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification. J Am Coll Cardiol 1997; 30(2): 46-443
-
(1997)
J Am Coll Cardiol
, vol.30 2
, pp. 436-443
-
-
Von Birgelen, C.1
Mintz, G.S.2
Nicosia, A.3
|