Volumn 62, Issue 2, 1998, Pages 115-121

Evaluation of an automatic intraluminal edge detection technique for intravascular ultrasound images

Author keywords

Acoustic; Automatic detection; Image processing; Intravascular ultrasound; Quantification

Indexed keywords

ARTICLE; BLOOD VESSEL DIAMETER; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; IMAGE ANALYSIS; IMAGE PROCESSING; INTRAVASCULAR ULTRASOUND;

EID: 0031951361     PISSN: 00471828     EISSN: None     Source Type: Journal    
DOI: 10.1253/jcj.62.115     Document Type: Article
Times cited : (11)

References (29)
  • 1
    • 0024447264 scopus 로고
    • Arterial wall characteristics determined by intravascular ultrasound imaging: An in vitro study
    • Gussenhoven EJ, Essed CE, Lancee CT, et al: Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study. J Am Coll Cardiol 1989; 14: 947-952
    • (1989) J Am Coll Cardiol , vol.14 , pp. 947-952
    • Gussenhoven, E.J.1    Essed, C.E.2    Lancee, C.T.3
  • 2
    • 0025352353 scopus 로고
    • Intravascular ultrasound imaging. In vitro validation and pathologic correlation
    • Nishimura RA, Edwards WD, Warnes CA, et al: Intravascular ultrasound imaging. In vitro validation and pathologic correlation. J Am Coll Cardiol 1990; 16: 145-154
    • (1990) J Am Coll Cardiol , vol.16 , pp. 145-154
    • Nishimura, R.A.1    Edwards, W.D.2    Warnes, C.A.3
  • 3
    • 0025250288 scopus 로고
    • Coronary artery imaging with intravascular high-frequency ultrasound
    • Potkin BN, Bartorelli AL, Gessert J, et al: Coronary artery imaging with intravascular high-frequency ultrasound. Circulation 1990; 81: 1575-1585
    • (1990) Circulation , vol.81 , pp. 1575-1585
    • Potkin, B.N.1    Bartorelli, A.L.2    Gessert, J.3
  • 4
    • 84910725322 scopus 로고
    • Identification of tissue-components in human atheroma by an intravascular ultrasound imaging catheter
    • Mallery JA, Tobis JM, Gessert J: Identification of tissue-components in human atheroma by an intravascular ultrasound imaging catheter. Circulation 1988; 78: II-22
    • (1988) Circulation , vol.78
    • Mallery, J.A.1    Tobis, J.M.2    Gessert, J.3
  • 5
    • 0026828549 scopus 로고
    • Detection and characterization of vascular lesions by intravascular ultrasound: An in vitro study correlated with histology
    • Di Mario C, The SHK, Madreestma S, Suylen RJ, et al: Detection and characterization of vascular lesions by intravascular ultrasound: an in vitro study correlated with histology. J Am Soc Echocardiogr 1992; 15: 1135-1146
    • (1992) J Am Soc Echocardiogr , vol.15 , pp. 1135-1146
    • Di Mario, C.1    The, S.H.K.2    Madreestma, S.3    Suylen, R.J.4
  • 7
    • 0026497729 scopus 로고
    • Intravascular ultrasound precisely detects, localizes, and quantifies coronary artery calcification
    • Mintz GS, Douek PC, Keren G, et al: Intravascular ultrasound precisely detects, localizes, and quantifies coronary artery calcification. J Am Coll Card 1992; 20: 1149-1155
    • (1992) J Am Coll Card , vol.20 , pp. 1149-1155
    • Mintz, G.S.1    Douek, P.C.2    Keren, G.3
  • 8
    • 0023002525 scopus 로고
    • Intimal plus medial thickness of the arterial wall: A direct measurement with ultrasound imaging
    • Pignoli P, Tremoli E, Poli A, Oreste P, Paoletti R: Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging. Circulation 1986; 6: 1399-1406
    • (1986) Circulation , vol.6 , pp. 1399-1406
    • Pignoli, P.1    Tremoli, E.2    Poli, A.3    Oreste, P.4    Paoletti, R.5
  • 9
    • 0027366710 scopus 로고
    • Artifacts in intravascular ultrasound imaging: Analyses and implications
    • Finet G, Maurincomme E, Tabib A, et al: Artifacts in intravascular ultrasound imaging: analyses and implications. Ultrasound Med Biol 1993; 19(7): 533-547
    • (1993) Ultrasound Med Biol , vol.19 , Issue.7 , pp. 533-547
    • Finet, G.1    Maurincomme, E.2    Tabib, A.3
  • 10
    • 0028111062 scopus 로고
    • Three-layer appearance of the arterial wall in intravascular ultrasound imaging: Artifact or reality? Implications for accurate measurements in quantitative intravascular ultrasound
    • Finet G, Maurincomme E, Douek Ph, et al: Three-layer appearance of the arterial wall in intravascular ultrasound imaging: artifact or reality? Implications for accurate measurements in quantitative intravascular ultrasound. Echocardiography 1994; 11: 343-363
    • (1994) Echocardiography , vol.11 , pp. 343-363
    • Finet, G.1    Maurincomme, E.2    Douek, Ph.3
  • 11
    • 0024372177 scopus 로고
    • Analysis of backscattered ultrasound from normal and diseased arterial wall
    • Linker DT, Yock PG, Gronningsaether A: Analysis of backscattered ultrasound from normal and diseased arterial wall. Int J Cardiac Imaging 1989; 4: 160-177
    • (1989) Int J Cardiac Imaging , vol.4 , pp. 160-177
    • Linker, D.T.1    Yock, P.G.2    Gronningsaether, A.3
  • 13
    • 0026066451 scopus 로고
    • Measurement of ultrasonic properties of vascular tissues and blood from 35-65 MHz
    • Lockwood GR, Ryan LK, Hunt JW: Measurement of ultrasonic properties of vascular tissues and blood from 35-65 MHz. Ultrasound Med Biol 1991; 17: 653-658
    • (1991) Ultrasound Med Biol , vol.17 , pp. 653-658
    • Lockwood, G.R.1    Ryan, L.K.2    Hunt, J.W.3
  • 14
    • 0023540244 scopus 로고
    • On matching deformable models to images
    • Washington, DC: Optical Society of America
    • Terzopoulos D: On matching deformable models to images. In: Topical meeting on machine vision, Technical Digest Series volume 12. Washington, DC: Optical Society of America, 1987: 160-163
    • (1987) Topical Meeting on Machine Vision, Technical Digest Series , vol.12 , pp. 160-163
    • Terzopoulos, D.1
  • 16
    • 0005196882 scopus 로고
    • On active contour models and balloons
    • Cohen L: On active contour models and balloons. CVGIP: Image Understanding, 1991; 53(2): 211-218
    • (1991) CVGIP: Image Understanding , vol.53 , Issue.2 , pp. 211-218
    • Cohen, L.1
  • 19
    • 0017348841 scopus 로고
    • Quantitative coronary arteriography, estimation of dimensions, hemodynamic resistance and atheroma mass of coronary artery lesions using the arteriogram and digital computation
    • Brown BG, Bolson E, Frimer M, Dodge HT: Quantitative coronary arteriography, estimation of dimensions, hemodynamic resistance and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation 1977; 55: 329-334
    • (1977) Circulation , vol.55 , pp. 329-334
    • Brown, B.G.1    Bolson, E.2    Frimer, M.3    Dodge, H.T.4
  • 20
    • 0026566406 scopus 로고
    • 3D-area reconstruction of intravascular ultrasound images using personal computer hardware and a motorized catheter control
    • Klein HM, Günther RW, Verlande M, et al: 3D-area reconstruction of intravascular ultrasound images using personal computer hardware and a motorized catheter control. Cardiovasc Intervent Radiol 1992; 15: 97-104
    • (1992) Cardiovasc Intervent Radiol , vol.15 , pp. 97-104
    • Klein, H.M.1    Günther, R.W.2    Verlande, M.3
  • 21
    • 0026963790 scopus 로고
    • Methodology for three-dimensional reconstruction of intravascular ultrasound images
    • Yongmin Kim, editor, Newport Beach, CA, February
    • Maurincomme E, Magnin IE, Finet G, Goutte R: Methodology for three-dimensional reconstruction of intravascular ultrasound images. In: Yongmin Kim, editor, Medical imaging VI: image capture, formatting, and display, volume SPIE 1653. Newport Beach, CA, February 1992: 26-34
    • (1992) Medical Imaging VI: Image Capture, Formatting, and Display , vol.SPIE 1653 , pp. 26-34
    • Maurincomme, E.1    Magnin, I.E.2    Finet, G.3    Goutte, R.4
  • 22
    • 0028105943 scopus 로고
    • Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions
    • Roelandt JRTC, Di Mario C, Pandian NG, et al: Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions. Circulation 1994; 90: 1044-1055
    • (1994) Circulation , vol.90 , pp. 1044-1055
    • Roelandt, J.R.T.C.1    Di Mario, C.2    Pandian, N.G.3
  • 23
    • 0005112933 scopus 로고    scopus 로고
    • What are the advantages and limitations of three-dimensional intracoronary ultrasound imaging?
    • Reiber JHC and van der Wall EE, editors. Netherlands: Kluwer Academic Publishers
    • Maurincomme E, Finet G: What are the advantages and limitations of three-dimensional intracoronary ultrasound imaging? In: Reiber JHC and van der Wall EE, editors. Cardiovascular imaging. Netherlands: Kluwer Academic Publishers, 1996: 243-255
    • (1996) Cardiovascular Imaging , pp. 243-255
    • Maurincomme, E.1    Finet, G.2
  • 24
    • 0000858899 scopus 로고
    • Semiautomatic contour detection for volumetric quantification of intracoronary ultrasound
    • Li W, von Birgelen C, Di Mario C, et al: Semiautomatic contour detection for volumetric quantification of intracoronary ultrasound. Comput Cardiol 1994; 4: 277-280
    • (1994) Comput Cardiol , vol.4 , pp. 277-280
    • Li, W.1    Von Birgelen, C.2    Di Mario, C.3
  • 25
    • 0027397420 scopus 로고
    • The angle of incidence of the ultrasonic beam: A critical factor for the image quality in intravascular ultrasonography
    • Di Mario C, Madretsma S, Linker D, et al: The angle of incidence of the ultrasonic beam: a critical factor for the image quality in intravascular ultrasonography. Am Heart J 1993; 125: 442-448
    • (1993) Am Heart J , vol.125 , pp. 442-448
    • Di Mario, C.1    Madretsma, S.2    Linker, D.3
  • 26
    • 0028266125 scopus 로고
    • Temporal averaging for quantification of lumen dimensions in intravascular ultrasound images
    • Li W, Gussenhoven EJ, Zhong Y, et al: Temporal averaging for quantification of lumen dimensions in intravascular ultrasound images. Ultrasound Med Biol 1994; 20: 117-122
    • (1994) Ultrasound Med Biol , vol.20 , pp. 117-122
    • Li, W.1    Gussenhoven, E.J.2    Zhong, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.