-
1
-
-
0032767558
-
Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
-
Aufrichtig R 1999 Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography Med. Phys. 26 1349-58
-
(1999)
Med. Phys.
, vol.26
, pp. 1349-1358
-
-
Aufrichtig, R.1
-
2
-
-
0030064443
-
Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample
-
Beam C A, Layde P M and Sullivan D C 1996 Variability in the interpretation of screening mammograms by US radiologists - findings from a national sample Arch. Intern. Med. 156 209-13
-
(1996)
Arch. Intern. Med.
, vol.156
, pp. 209-213
-
-
Beam, C.A.1
Layde, P.M.2
Sullivan, D.C.3
-
3
-
-
0026655955
-
Analysis of cancers missed at screening mammography
-
Bird R E, Wallace T W and Yankaskas B C 1992 Analysis of cancers missed at screening mammography Radiology 184 613-7
-
(1992)
Radiology
, vol.184
, pp. 613-617
-
-
Bird, R.E.1
Wallace, T.W.2
Yankaskas, B.C.3
-
4
-
-
0035190741
-
Dedicated breast CT: Radiation dose and image quality evaluation
-
Boone J M, Nelson T R, Lindfors K K and Seibert J A 2001 Dedicated breast CT: radiation dose and image quality evaluation Radiology 221 657-67
-
(2001)
Radiology
, vol.221
, pp. 657-667
-
-
Boone, J.M.1
Nelson, T.R.2
Lindfors, K.K.3
Seibert, J.A.4
-
5
-
-
0344163437
-
Effects of stereoscopic imaging technique on depth discrimination
-
Proc. IWDM 2000 - 5th Int. Workshop on Digital Mammography, Digital Mammography (Toronto, Canada) ed M J Yaffe (Madison, WI: Medical Physics Publishing)
-
Chan H P, Goodsitt M M, Darner K L, Sullivan J M, Hadjiiski L M, Petrick N and Sahiner B 2001 Effects of stereoscopic imaging technique on depth discrimination Proc. IWDM 2000 - 5th Int. Workshop on Digital Mammography, Digital Mammography (Toronto, Canada) ed M J Yaffe (Madison, WI: Medical Physics Publishing) pp 13-8
-
(2001)
, pp. 13-18
-
-
Chan, H.P.1
Goodsitt, M.M.2
Darner, K.L.3
Sullivan, J.M.4
Hadjiiski, L.M.5
Petrick, N.6
Sahiner, B.7
-
6
-
-
0036033696
-
Digital stereomammography: Observer performance study of the effects of magnification and zooming on depth perception
-
4682
-
Chan H P, Goodsitt M M, Hadjiiski L, Bailey J E, Klein K, Darner K L and Paramagul C 2002a Digital stereomammography: observer performance study of the effects of magnification and zooming on depth perception Proc. SPIE 4682 163-6
-
(2002)
Proc. SPIE
, pp. 163-166
-
-
Chan, H.P.1
Goodsitt, M.M.2
Hadjiiski, L.3
Bailey, J.E.4
Klein, K.5
Darner, K.L.6
Paramagul, C.7
-
7
-
-
4244108523
-
Development of digital stereo imaging technique for mammography
-
Era of Hope Meeting (U.S. Army Medical Research and Material Command, Department of Defense, Breast Cancer Research Program, Orlando, Florida, September 25-28)
-
Chan H P, Goodsitt M M, Hadjiiski L M, Helvie M A, Bailey J, Klein K and Roubidoux M A 2002b Development of digital stereo imaging technique for mammography Era of Hope Meeting (U.S. Army Medical Research and Material Command, Department of Defense, Breast Cancer Research Program, Orlando, Florida, September 25-28)
-
(2002)
-
-
Chan, H.P.1
Goodsitt, M.M.2
Hadjiiski, L.M.3
Helvie, M.A.4
Bailey, J.5
Klein, K.6
Roubidoux, M.A.7
-
8
-
-
0344594953
-
ROC study comparing radiologists' performances in evaluating breast lesions on stereoscopic and single-projection digital specimen mammograms
-
(abstract)
-
Chan H P, Goodsitt M M, Hadjiiski L, Roubidoux M A, Bailey J E, Helvie M A, Lydick J T and Sahiner B 2003 ROC study comparing radiologists' performances in evaluating breast lesions on stereoscopic and single-projection digital specimen mammograms Med. Phys. 30 1456 (abstract)
-
(2003)
Med. Phys.
, vol.30
, pp. 1456
-
-
Chan, H.P.1
Goodsitt, M.M.2
Hadjiiski, L.3
Roubidoux, M.A.4
Bailey, J.E.5
Helvie, M.A.6
Lydick, J.T.7
Sahiner, B.8
-
9
-
-
0344163438
-
Depth perception in digital stereoscopic mammography
-
Era of Hope Meeting (U.S. Army Medical Research and Material Command, Department of Defense, Breast Cancer Research Program, Atlanta, Georgia, June 8-12)
-
Chan H P, Goodsitt M M, Sullivan J M, Darner K L and Hadjiiski L M 2000 Depth perception in digital stereoscopic mammography Era of Hope Meeting (U.S. Army Medical Research and Material Command, Department of Defense, Breast Cancer Research Program, Atlanta, Georgia, June 8-12)
-
(2000)
-
-
Chan, H.P.1
Goodsitt, M.M.2
Sullivan, J.M.3
Darner, K.L.4
Hadjiiski, L.M.5
-
10
-
-
0005194662
-
Small field-of-view digital imaging of breast calcifications: Method to improve diagnostic specificity
-
Conant E F, Maidment A D, Albert M, Piccoli C W, Nussbaum S A and McCue P A 1996 Small field-of-view digital imaging of breast calcifications: method to improve diagnostic specificity Radiology 201(P) 369
-
(1996)
Radiology
, vol.201
, Issue.P
, pp. 369
-
-
Conant, E.F.1
Maidment, A.D.2
Albert, M.3
Piccoli, C.W.4
Nussbaum, S.A.5
McCue, P.A.6
-
12
-
-
0020666366
-
Detectability of depth information by use of magnification stereoscopic technique in cerebral angiography
-
Doi K and Duda E E 1983 Detectability of depth information by use of magnification stereoscopic technique in cerebral angiography Radiology 146 91-5
-
(1983)
Radiology
, vol.146
, pp. 91-95
-
-
Doi, K.1
Duda, E.E.2
-
13
-
-
0017331148
-
Noise reduction by radiographic magnification
-
Doi K and Imhof H 1977 Noise reduction by radiographic magnification Radiology 122 479-87
-
(1977)
Radiology
, vol.122
, pp. 479-487
-
-
Doi, K.1
Imhof, H.2
-
14
-
-
0019757943
-
X-ray imaging of blood vessels to the brain by use of magnification stereoscopic technique
-
Doi K, Patronas N J, Duda E E, Geldner E and Dietz K 1981 X-ray imaging of blood vessels to the brain by use of magnification stereoscopic technique Adv. Neurol. 30 175-89
-
(1981)
Adv. Neurol.
, vol.30
, pp. 175-189
-
-
Doi, K.1
Patronas, N.J.2
Duda, E.E.3
Geldner, E.4
Dietz, K.5
-
15
-
-
0016333722
-
The effect of radiographic magnification on blood vessel imaging with various screen-film systems
-
Doi K and Rossmann K 1974 The effect of radiographic magnification on blood vessel imaging with various screen-film systems Med. Phys. 1 257-61
-
(1974)
Med. Phys.
, vol.1
, pp. 257-261
-
-
Doi, K.1
Rossmann, K.2
-
16
-
-
0002547014
-
Stereoscopic digital mammography: Improving detection and diagnosis of breast cancer
-
Computer Assisted Radiology and Surgery 2001, Proc. 15th Int. Congress and Exhibition (Berlin) (International Congress Series 1230) ed H U Lemke, M W Vannier, K Inamura, A G Farman and K Doi (Amsterdam: Elsevier)
-
Getty D J, Pickett R M and D'Orsi C J 2001 Stereoscopic digital mammography: improving detection and diagnosis of breast cancer Computer Assisted Radiology and Surgery 2001, Proc. 15th Int. Congress and Exhibition (Berlin) (International Congress Series 1230) ed H U Lemke, M W Vannier, K Inamura, A G Farman and K Doi (Amsterdam: Elsevier) pp 506-11
-
(2001)
, pp. 506-511
-
-
Getty, D.J.1
Pickett, R.M.2
D'Orsi, C.J.3
-
17
-
-
0036853445
-
The effects of stereo shift angle, geometric magnification and display zoom on depth measurements in digital stereomammography
-
Goodsitt M M, Chan H P, Darner K L and Hadjiiski L M 2002 The effects of stereo shift angle, geometric magnification and display zoom on depth measurements in digital stereomammography Med. Phys. 29 2725-34
-
(2002)
Med. Phys.
, vol.29
, pp. 2725-2734
-
-
Goodsitt, M.M.1
Chan, H.P.2
Darner, K.L.3
Hadjiiski, L.M.4
-
18
-
-
0034089118
-
Stereomammography: Evaluation of depth perception using a virtual 3D cursor
-
Goodsitt M M, Chan H P and Hadjiiski L M 2000 Stereomammography: evaluation of depth perception using a virtual 3D cursor Med. Phys. 27 1305-10
-
(2000)
Med. Phys.
, vol.27
, pp. 1305-1310
-
-
Goodsitt, M.M.1
Chan, H.P.2
Hadjiiski, L.M.3
-
19
-
-
0027136285
-
Previous mammograms in patients with impalpable breast carcinomas: Retrospective vs blinded interpretation
-
Harvey J A, Fajardo L L and Innis C A 1993 Previous mammograms in patients with impalpable breast carcinomas: retrospective vs blinded interpretation Am. J. Roentgenol. 161 1167-72
-
(1993)
Am. J. Roentgenol.
, vol.161
, pp. 1167-1172
-
-
Harvey, J.A.1
Fajardo, L.L.2
Innis, C.A.3
-
20
-
-
0023764163
-
Depth determination on stereoscopic digital subtraction angiograms
-
Higashida Y, Hirata Y, Saito R, Doudanuki S, Bussaka H and Takahashi M 1988 Depth determination on stereoscopic digital subtraction angiograms Radiology 168 560-2
-
(1988)
Radiology
, vol.168
, pp. 560-562
-
-
Higashida, Y.1
Hirata, Y.2
Saito, R.3
Doudanuki, S.4
Bussaka, H.5
Takahashi, M.6
-
22
-
-
0020086252
-
Cost-effectiveness of stereoscopic radiographs in detection of lung nodules
-
Kelsey C A, Moseley R D, Mettler S A and Briscoe D E 1982 Cost-effectiveness of stereoscopic radiographs in detection of lung nodules Radiology 142 611-3
-
(1982)
Radiology
, vol.142
, pp. 611-613
-
-
Kelsey, C.A.1
Moseley, R.D.2
Mettler, S.A.3
Briscoe, D.E.4
-
23
-
-
0021998968
-
Investigation of basic imaging properties in digital radiography: 4. Effect of unsharp masking on the detectability of simple patterns
-
Loo L N, Doi K and Metz C E 1985 Investigation of basic imaging properties in digital radiography: 4. Effect of unsharp masking on the detectability of simple patterns Med. Phys. 12 209-14
-
(1985)
Med. Phys.
, vol.12
, pp. 209-214
-
-
Loo, L.N.1
Doi, K.2
Metz, C.E.3
-
24
-
-
0005190208
-
Prototype workstation for 3-D diagnosis of breast calcifications
-
Maidment A D A, Albert M, Conant E F, Piccoli C W and McCue P A 1996 Prototype workstation for 3-D diagnosis of breast calcifications Radiology 201(P) 556
-
(1996)
Radiology
, vol.201
, Issue.P
, pp. 556
-
-
Maidment, A.D.A.1
Albert, M.2
Conant, E.F.3
Piccoli, C.W.4
McCue, P.A.5
-
25
-
-
25544438796
-
Is stereomammography possible without increasing dose?
-
Proc. IWDM 2002 - 6th Int. Workshop on Digital Mammography, Digital Mammography (Bremen, Germany) ed H Petitgen (Berlin: Springer)
-
Maidment A D A, Bakic P and Alberg M 2003 Is stereomammography possible without increasing dose? Proc. IWDM 2002 - 6th Int. Workshop on Digital Mammography, Digital Mammography (Bremen, Germany) ed H Petitgen (Berlin: Springer) pp 510-5
-
(2003)
, pp. 510-515
-
-
Maidment, A.D.A.1
Bakic, P.2
Alberg, M.3
-
26
-
-
0030711575
-
Digital tomosynthesis in breast imaging
-
Niklason L T et al 1997 Digital tomosynthesis in breast imaging Radiology 205 399-406
-
(1997)
Radiology
, vol.205
, pp. 399-406
-
-
Niklason, L.T.1
-
27
-
-
0026444793
-
Factors influencing postoperative movement in displaced femoral neck fractures: Evaluation by conventional radiography and stereoradiography
-
Ragnarsson J I and Karrholm J 1992 Factors influencing postoperative movement in displaced femoral neck fractures: evaluation by conventional radiography and stereoradiography J. Orthop. Trauma 6 152-8
-
(1992)
J. Orthop. Trauma
, vol.6
, pp. 152-158
-
-
Ragnarsson, J.I.1
Karrholm, J.2
-
28
-
-
0029873546
-
High resolution CT mammography of surgical biopsy specimens
-
Raptopoulos V, Baum J K, Hochman M, Karellas A, Houlihan M J and D'Orsi C J 1996 High resolution CT mammography of surgical biopsy specimens J. Comput. Assist. Tomogr. 20 179-84
-
(1996)
J. Comput. Assist. Tomogr.
, vol.20
, pp. 179-184
-
-
Raptopoulos, V.1
Baum, J.K.2
Hochman, M.3
Karellas, A.4
Houlihan, M.J.5
D'Orsi, C.J.6
-
29
-
-
0023627402
-
Survival experience in the breast cancer detection demonstration project
-
Seidman H, Gelb S K, Silverberg E, LaVerda N and Lubera J A 1987 Survival experience in the breast cancer detection demonstration project CA Cancer J. Clin. 37 258-90
-
(1987)
CA Cancer J. Clin.
, vol.37
, pp. 258-290
-
-
Seidman, H.1
Gelb, S.K.2
Silverberg, E.3
LaVerda, N.4
Lubera, J.A.5
-
30
-
-
0019509337
-
Stereoacuity norms in young children
-
Simons K 1981 Stereoacuity norms in young children Arch. Ophthalmol. 99 435-45
-
(1981)
Arch. Ophthalmol.
, vol.99
, pp. 435-445
-
-
Simons, K.1
-
31
-
-
0033673866
-
Comparison of tomosynthesis methods used with digital mammography
-
Suryanarayanan S, Karellas A, Vedantham S, Glick S J, D'Orsi C J, Baker S P and Webber R L 2000 Comparison of tomosynthesis methods used with digital mammography Acad. Radiol. 7 1085-97
-
(2000)
Acad. Radiol.
, vol.7
, pp. 1085-1097
-
-
Suryanarayanan, S.1
Karellas, A.2
Vedantham, S.3
Glick, S.J.4
D'Orsi, C.J.5
Baker, S.P.6
Webber, R.L.7
-
33
-
-
0025908633
-
A review of false negative mammography in a symptomatic population
-
Wallis M G, Walsh M T and Lee J R 1991 A review of false negative mammography in a symptomatic population Clin. Radiol. 44 13-5
-
(1991)
Clin. Radiol.
, vol.44
, pp. 13-15
-
-
Wallis, M.G.1
Walsh, M.T.2
Lee, J.R.3
|