Volumn 80, Issue 9 SUPPL., 1999, Pages 988-997

Spiral CT angiography: Reformating techniques;Techniques de reconstruction en angioscanographie spiralee

Author keywords

Computed tomography (CT); Helical; Image display and recording; Maximum intensity projection; Technology; Volume rendering

Indexed keywords

ANGIOGRAPHY; ARTICLE; IMAGE DISPLAY; IMAGE RECONSTRUCTION; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; TECHNIQUE; THREE DIMENSIONAL IMAGING;

EID: 0343729500     PISSN: 02210363     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (29)
  • 3
    • 0026712389 scopus 로고
    • Évaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A, Kalender WA, Marchal G. Évaluation of section sensitivity profiles and image noise in spiral CT. Radiology 1992;185:29-35.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 4
    • 0028230441 scopus 로고
    • Stair-step artifacts in three-dimensional helical CT : An experimental study
    • Wang GE, Vannier MW. Stair-step artifacts in three-dimensional helical CT : an experimental study. Radiology 1994;191:79-83.
    • (1994) Radiology , vol.191 , pp. 79-83
    • Wang, G.E.1    Vannier, M.W.2
  • 5
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT : An experimental study on the detection of spherical lesions
    • Kalander WA, Polacin A, Suss Ch. A comparison of conventional and spiral CT : an experimental study on the detection of spherical lesions. J Comp Assist Tomogr 1994;18:167-76.
    • (1994) J Comp Assist Tomogr , vol.18 , pp. 167-176
    • Kalander, W.A.1    Polacin, A.2    Suss, Ch.3
  • 7
    • 0031600214 scopus 로고    scopus 로고
    • Multiplanar and three-dimensional reconstruction techniques in CT : Impact on chest diseases
    • Rémy J, Rémy-Jardin M, Artaud D, Fribourg M. Multiplanar and three-dimensional reconstruction techniques in CT : impact on chest diseases. Eur Radiol 1998;8:335-51.
    • (1998) Eur Radiol , vol.8 , pp. 335-351
    • Rémy, J.1    Rémy-Jardin, M.2    Artaud, D.3    Fribourg, M.4
  • 8
    • 0029298850 scopus 로고
    • Helical CT angiography with multiplanar reformation : Techniques and clinical applications
    • Ibukuro K, Charnsanga VEJ C, Chasen MH et al. Helical CT angiography with multiplanar reformation : techniques and clinical applications. Radiographics 1995;15:671-82.
    • (1995) Radiographics , vol.15 , pp. 671-682
    • Ibukuro, K.1    Charnsanga, V.E.J.C.2    Chasen, M.H.3
  • 11
    • 0029334523 scopus 로고
    • Three-dimensional spiral CT during arterial portography : Comparison of three rendering techniques
    • Heath DG, Soyer PA, Kuszyk BS et al. Three-dimensional spiral CT during arterial portography : comparison of three rendering techniques. Radiographics 1995;15:1001-11.
    • (1995) Radiographics , vol.15 , pp. 1001-1011
    • Heath, D.G.1    Soyer, P.A.2    Kuszyk, B.S.3
  • 12
    • 0027397681 scopus 로고
    • Effect of image display on the quality of multiplanar reconstruction of computed tomography data invest
    • Fishman EK, Ney DR, Kawashima A, Scott WW, Robertson DD. Effect of image display on the quality of multiplanar reconstruction of computed tomography data Invest. Radiology 1993;28:146-9.
    • (1993) Radiology , vol.28 , pp. 146-149
    • Fishman, E.K.1    Ney, D.R.2    Kawashima, A.3    Scott, W.W.4    Robertson, D.D.5
  • 13
    • 0029393719 scopus 로고
    • Increased scan pitch for vascular and thoracic spiral CT
    • Rubin GD, Napel S. Increased scan pitch for vascular and thoracic spiral CT. Radiology 1995;197:316-7.
    • (1995) Radiology , vol.197 , pp. 316-317
    • Rubin, G.D.1    Napel, S.2
  • 14
    • 0001366420 scopus 로고    scopus 로고
    • Techniques of reconstruction
    • Rémy-Jardin M., Rémy J. (eds); Springer-Verlag, Berlin, Heidelberg
    • Rubin GD. Techniques of reconstruction, in Rémy-Jardin M., Rémy J. (eds) Spiral CT of the Chest ; Springer-Verlag, Berlin, Heidelberg, 1996, p. 101-27.
    • (1996) Spiral CT of the Chest , pp. 101-127
    • Rubin, G.D.1
  • 15
    • 0029150684 scopus 로고
    • CT angiography with volume rendering : Imaging findings
    • Kuszyk BS, Heath DG, Ney DR, et al. CT angiography with volume rendering : imaging findings. AJR 1995;165:445-8.
    • (1995) AJR , vol.165 , pp. 445-448
    • Kuszyk, B.S.1    Heath, D.G.2    Ney, D.R.3
  • 16
    • 0028364496 scopus 로고
    • Angioarchitecture of pulmonary arteriovenous malformations : Clinical utility of three-dimensional helical CT
    • Rémy J, Rémy-Jardin M, Giraud F, Wattinne L. Angioarchitecture of pulmonary arteriovenous malformations : clinical utility of three-dimensional helical CT. Radiology 1994;191:657-64.
    • (1994) Radiology , vol.191 , pp. 657-664
    • Rémy, J.1    Rémy-Jardin, M.2    Giraud, F.3    Wattinne, L.4
  • 17
    • 0031051390 scopus 로고    scopus 로고
    • CT angiography of carotid bifurcation : Artifacts and pitfalls in shaded surface display
    • Takahashi M, Ashtari M, Papp Z, et al. CT angiography of carotid bifurcation : artifacts and pitfalls in shaded surface display. AJR 1997;168:813-7.
    • (1997) AJR , vol.168 , pp. 813-817
    • Takahashi, M.1    Ashtari, M.2    Papp, Z.3
  • 18
    • 0031087152 scopus 로고    scopus 로고
    • Use of maximum intensity projections in CT angiography : A basic review
    • Prokop M, Shin HO, Schanz A, Schaefer-Prokop CM. Use of maximum intensity projections in CT angiography : a basic review. Radiographics 1997;17:433-51.
    • (1997) Radiographics , vol.17 , pp. 433-451
    • Prokop, M.1    Shin, H.O.2    Schanz, A.3    Schaefer-Prokop, C.M.4
  • 19
    • 0025070034 scopus 로고
    • Artifacts in maximum-intensity-projection display of MR angiograms
    • Anderson CM, Saloner D, Tsuruda JS, Shapeero LG, Lee RE. Artifacts in maximum-intensity-projection display of MR angiograms. AJR 1990;154:623-9.
    • (1990) AJR , vol.154 , pp. 623-629
    • Anderson, C.M.1    Saloner, D.2    Tsuruda, J.S.3    Shapeero, L.G.4    Lee, R.E.5
  • 21
    • 0030028916 scopus 로고    scopus 로고
    • Comparison of projection algorithms used for the construction of maximum intensity projection images
    • Schreiner S, Paschal CB, Galloway RL. Comparison of projection algorithms used for the construction of maximum intensity projection images. J Comput Assist Tomogr 1996;20:56-67.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 56-67
    • Schreiner, S.1    Paschal, C.B.2    Galloway, R.L.3
  • 22
    • 0029781840 scopus 로고    scopus 로고
    • Three-dimensional CT : Real-time interactive volume rendering
    • Johnson PT, Heath DG, Bliss DF, Cabral B, Fishman EK. Three-dimensional CT : real-time interactive volume rendering. AJR 1996;167:581-3.
    • (1996) AJR , vol.167 , pp. 581-583
    • Johnson, P.T.1    Heath, D.G.2    Bliss, D.F.3    Cabral, B.4    Fishman, E.K.5
  • 23
    • 0029890839 scopus 로고    scopus 로고
    • CT angiography with volume rendering : Advantages and applications in splanchnic vascular imaging
    • Johnson PT, Heath DG, Kuszyk BS, Fishman EK. CT angiography with volume rendering : advantages and applications in splanchnic vascular imaging. Radiology 1996;200:564-8.
    • (1996) Radiology , vol.200 , pp. 564-568
    • Johnson, P.T.1    Heath, D.G.2    Kuszyk, B.S.3    Fishman, E.K.4
  • 24
    • 0031030288 scopus 로고    scopus 로고
    • CT angiography : Thoracic vascular imaging with interactive volume rendering technique
    • Johnson PT, Heath DG, Kuszyk BS, Fishman EK. CT angiography : thoracic vascular imaging with interactive volume rendering technique. J Comput Assist Tomogr 1997;21:110-4.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 110-114
    • Johnson, P.T.1    Heath, D.G.2    Kuszyk, B.S.3    Fishman, E.K.4
  • 25
    • 0031606391 scopus 로고    scopus 로고
    • Interactive three-dimensional volume rendering of spiral CT data: Current applications in the thorax
    • Johnson PT, Fishman EK, Duckwall JR, Calhoun PS, Heath DG. Interactive three-dimensional volume rendering of spiral CT data: current applications in the thorax. Radiographics 1998;18:165-87.
    • (1998) Radiographics , vol.18 , pp. 165-187
    • Johnson, P.T.1    Fishman, E.K.2    Duckwall, J.R.3    Calhoun, P.S.4    Heath, D.G.5
  • 27
    • 0030024197 scopus 로고    scopus 로고
    • Thoracic aortic aneurysm and aortic dissection : New endoscopic mode for three-dimensional CT display of aorta
    • Kimura F, Shen Y, Date S, Azemoto S, Mochizuki T. Thoracic aortic aneurysm and aortic dissection : new endoscopic mode for three-dimensional CT display of aorta. Radiology 1996;198:573-8.
    • (1996) Radiology , vol.198 , pp. 573-578
    • Kimura, F.1    Shen, Y.2    Date, S.3    Azemoto, S.4    Mochizuki, T.5
  • 28
    • 0031969772 scopus 로고    scopus 로고
    • Virtual angioscopy using spiral CT and real-time interactive volume rendering techniques
    • Smith PA, Heath DG, Fishman EK. Virtual angioscopy using spiral CT and real-time interactive volume rendering techniques. J Comput Assist Tomogr 1998;22:212-4.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 212-214
    • Smith, P.A.1    Heath, D.G.2    Fishman, E.K.3
  • 29
    • 0025399086 scopus 로고
    • Volumetric rendering of computed tomography data : Principles and techniques
    • Ney DR, Fishman EK, Magid D. Volumetric rendering of computed tomography data : principles and techniques. Comput Graphics Appl 1990;10:24-32.
    • (1990) Comput Graphics Appl , vol.10 , pp. 24-32
    • Ney, D.R.1    Fishman, E.K.2    Magid, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.