메뉴 건너뛰기




Volumn 28, Issue 5, 2001, Pages 757-763

Dosimetric effects of contrast media for catheter-based intravascular brachytherapy

Author keywords

Contrast medium; Dose calculation; Intravascular brachytherapy; Monte Carlo

Indexed keywords

CATHETERS; IODINE; MONTE CARLO METHODS; ONCOLOGY; RADIOTHERAPY;

EID: 0342468208     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1367279     Document Type: Article
Times cited : (15)

References (31)
  • 1
    • 0021245362 scopus 로고
    • "Restenosis after percutaneous transluminal coronary angioplasty (PTCA): A report for the PTCA registry of the national heart, lung, and blood institute,"
    • D. R. Holmes, Jr. et al., "Restenosis after percutaneous transluminal coronary angioplasty (PTCA): A report for the PTCA registry of the National Heart, Lung, and Blood Institute," Am. J. Cardiol. 53, 77C-81C (1984).
    • (1984) Am. J. Cardiol. , vol.53
    • Holmes D.R., Jr.1
  • 2
    • 0028224412 scopus 로고
    • Endovascular irradiation - A new method to avoid recurrent stenosis after stent implantation in peripheral arteries: Technique and preliminary results
    • H. D. Böttcher et al., "Endovascular irradiation - a new method to avoid recurrent stenosis after stent implantation in peripheral arteries: Technique and preliminary results," Int. J. Radiat. Oncol., Biol., Phys. 29, 183-189 (1994).
    • (1994) Int. J. Radiat. Oncol., Biol., Phys. , vol.29 , pp. 183-189
    • Böttcher, H.D.1
  • 3
    • 0028625454 scopus 로고
    • Low-dose, beta particle emission from 'stent' wire results in complete, localized inhibition of smooth muscle cell proliferation
    • T. A. Fischell et al., "Low-dose, beta particle emission from 'stent' wire results in complete, localized inhibition of smooth muscle cell proliferation," Circulation 90, 2956-2963 (1994).
    • (1994) Circulation , vol.90 , pp. 2956-2963
    • Fischell, T.A.1
  • 4
    • 0027938454 scopus 로고
    • Effects of high dose intracoronary irradiation on vasomotor function and smooth muscle histopathology
    • J. Wiederman et al., "Effects of high dose intracoronary irradiation on vasomotor function and smooth muscle histopathology," Am. J. Physiol. 267, H125-H132 (1994).
    • (1994) Am. J. Physiol. , vol.267
    • Wiederman, J.1
  • 5
    • 0029152039 scopus 로고
    • High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: Preliminary dosimetric tests of a new source presentation
    • Y. Popowski et al., "High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: Preliminary dosimetric tests of a new source presentation," Int. J. Radiat. Oncol., Biol., Phys. 33, 211-215 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.33 , pp. 211-215
    • Popowski, Y.1
  • 6
    • 18144448777 scopus 로고    scopus 로고
    • Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans
    • J. A. Condado et al., "Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans," Circulation 96, 727-732 (1997).
    • (1997) Circulation , vol.96 , pp. 727-732
    • Condado, J.A.1
  • 7
    • 0028959726 scopus 로고
    • Endovascular low-dose irradiation inhibits neointima formation after coronary artery balloon injury in swine: A possible role for radiation therapy in restenosis prevention
    • R. Waksman et al., "Endovascular low-dose irradiation inhibits neointima formation after coronary artery balloon injury in swine: A possible role for radiation therapy in restenosis prevention," Circulation 91, 1533-1539 (1995).
    • (1995) Circulation , vol.91 , pp. 1533-1539
    • Waksman, R.1
  • 8
    • 0003971553 scopus 로고
    • edited by S. B. King III, R. Waksman, and I. Crocker Emory University School of Medicine Press, Atlanta
    • Discoveries in Radiation for Restenosis, edited by S. B. King III, R. Waksman, and I. Crocker (Emory University School of Medicine Press, Atlanta, 1995).
    • (1995) Discoveries in Radiation for Restenosis
  • 10
    • 0030292918 scopus 로고    scopus 로고
    • Dosimetric considerations for catheter based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries
    • H. I. Amols et al., "Dosimetric considerations for catheter based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries," Int. J. Radiat. Oncl., Biol., Phys. 36, 913-921 (1996).
    • (1996) Int. J. Radiat. Oncl., Biol., Phys. , vol.36 , pp. 913-921
    • Amols, H.I.1
  • 11
    • 0032941450 scopus 로고    scopus 로고
    • Intravascular brachytherapy physics: Report of AAPM radiation therapy committee task group no. 60
    • R. Nath et al., "Intravascular brachytherapy physics: Report of AAPM Radiation Therapy Committee Task Group No. 60," Med. Phys. 26, 119-151 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 119-151
    • Nath, R.1
  • 13
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no. 34
    • R. Nath et al., "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group No. 34," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1
  • 14
    • 0032506255 scopus 로고    scopus 로고
    • Intracoronary radiation for prevention of restenosis: Dose perturbations caused by stents
    • H. I. Amols, F. Trichter, and J. Weinberger, "Intracoronary radiation for prevention of restenosis: Dose perturbations caused by stents," Circulation 98, 2024-2029 (1998).
    • (1998) Circulation , vol.98 , pp. 2024-2029
    • Amols, H.I.1    Trichter, F.2    Weinberger, J.3
  • 15
    • 0034001425 scopus 로고    scopus 로고
    • Beta versus gamma for intravascular brachytherapy: Dosimetric perspectives in the presence of metallic stents and calcified plaques
    • X. A. Li, R. Wang, C. Yu, and M. Suntharalingam, "Beta versus gamma for intravascular brachytherapy: Dosimetric perspectives in the presence of metallic stents and calcified plaques," Int. J. Radiat. Oncol., Biol., Phys. 46, 1043-1049 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.46 , pp. 1043-1049
    • Li, X.A.1    Wang, R.2    Yu, C.3    Suntharalingam, M.4
  • 16
    • 0034047103 scopus 로고    scopus 로고
    • Dosimetric perturbations of linear array of β emitters and metallic stents in intravascular brachytherapy
    • S. J. Ye et al., "Dosimetric perturbations of linear array of β emitters and metallic stents in intravascular brachytherapy," Med. Phys. 27, 374-380 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 374-380
    • Ye, S.J.1
  • 17
    • 0032956067 scopus 로고    scopus 로고
    • The effect of contrast medium and balloon shape on dosimetry for arterial irradiation with
    • 188Re, Med. Phys. 26, 771-776 (1999).
    • (1999) 188Re, Med. Phys. , vol.26 , pp. 771-776
    • Fox, R.A.1    Henson, P.W.2
  • 19
    • 0026595708 scopus 로고
    • Calculation of radiation dose enhancement factors for dose enhancement therapy of brain tumors
    • T. D. Solberg, K. S. Iwamoto, and A. Norman, "Calculation of radiation dose enhancement factors for dose enhancement therapy of brain tumors," Phys. Med. Biol. 37, 439-443 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 439-443
    • Solberg, T.D.1    Iwamoto, K.S.2    Norman, A.3
  • 20
    • 0032792549 scopus 로고    scopus 로고
    • Dose distributions using kilovoltage x-rays and dose enhancement from iodine contrast agents
    • A. V. Mesa, A. Norman, T. D. Solberg, J. J. Demarco, and J. B. Smathers, "Dose distributions using kilovoltage x-rays and dose enhancement from iodine contrast agents," Phys. Med. Biol. 44, 1955-1968 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1955-1968
    • Mesa, A.V.1    Norman, A.2    Solberg, T.D.3    Demarco, J.J.4    Smathers, J.B.5
  • 21
    • 0033108185 scopus 로고    scopus 로고
    • Dose perturbations by high atomic number materials in intravascular brachytherapy
    • R. Nath, Y. Ning, and J. Weinberger, "Dose perturbations by high atomic number materials in intravascular brachytherapy," Cardiovasc. Radiat. Med. 1, 144-153 (1999).
    • (1999) Cardiovasc. Radiat. Med. , vol.1 , pp. 144-153
    • Nath, R.1    Ning, Y.2    Weinberger, J.3
  • 23
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history monte carlo simulation of electron transport. I. EGSnrc the new EGS4 version
    • I. Kawrakow, "Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc the new EGS4 version," Med. Phys. 27, 485-498 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 25
    • 0023138959 scopus 로고
    • PRESTA: The parameter reduced electron-step transport algorithm for electron Monte Carlo transport
    • A. F. Bielajew and D. W. O. Rogers, "PRESTA: The parameter reduced electron-step transport algorithm for electron Monte Carlo transport," Nucl. Instrum. Methods Phys. Res. B 18, 165-181 (1987).
    • (1987) Nucl. Instrum. Methods Phys. Res. B , vol.18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 26
    • 0033863191 scopus 로고    scopus 로고
    • Evaluation of EGS4 for Sr-Y 90 intravascular brachytherapy dosimetry
    • R. Wang, X. A. Li, and C. X. Yu, "Evaluation of EGS4 for Sr-Y 90 intravascular brachytherapy dosimetry," Phys. Med. Biol. 45, 2343-2352 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2343-2352
    • Wang, R.1    Li, X.A.2    Yu, C.X.3
  • 28
    • 0035117289 scopus 로고    scopus 로고
    • Monte Carlo calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc and MCNP
    • R. Wang and X. A. Li, "Monte Carlo calculations of beta-emitting sources for intravascular brachytherapy: A comparison between EGS4, EGSnrc and MCNP," Med. Phys. 28, 134-141 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 134-141
    • Wang, R.1    Li, X.A.2
  • 29
    • 0021072709 scopus 로고
    • A short atlas of beta-ray spectra
    • W. G. Cross, H. Ing, and N. Freedman, "A short atlas of beta-ray spectra," Phys. Med. Biol. 28, 1251-1260 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1251-1260
    • Cross, W.G.1    Ing, H.2    Freedman, N.3
  • 31
    • 0033678807 scopus 로고    scopus 로고
    • 192Ir SS sources for intravascular brachytherapy
    • 192Ir SS sources for intravascular brachytherapy. Med. Phys. 27, 2528-2535 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2528-2535
    • Wang, R.1    Li, X.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.