Volumn 45, Issue 8, 2000, Pages 2343-2352
|
Evaluation of EGS4/PRESTA multiple-scattering algorithms for 90Sr/90Y intravascular brachytherapy dosimetry
|
Author keywords
[No Author keywords available]
|
Indexed keywords
STRONTIUM 90;
YTTRIUM 90;
ACCURACY;
ALGORITHM;
ARTICLE;
BRACHYTHERAPY;
DOSE CALCULATION;
DOSIMETRY;
ELECTRON;
PRIORITY JOURNAL;
RADIATION DOSE;
RADIATION SCATTERING;
SYSTEM ANALYSIS;
ALGORITHMS;
BRACHYTHERAPY;
ELECTRONS;
MODELS, STATISTICAL;
MONTE CARLO METHOD;
RADIOMETRY;
SCATTERING, RADIATION;
STRONTIUM RADIOISOTOPES;
YTTRIUM RADIOISOTOPES;
|
EID: 0033863191
PISSN: 00319155
EISSN: None
Source Type: Journal
DOI: 10.1088/0031-9155/45/8/319 Document Type: Article |
Times cited : (11)
|
References (13)
|