메뉴 건너뛰기




Volumn 45, Issue 8, 2000, Pages 2343-2352

Evaluation of EGS4/PRESTA multiple-scattering algorithms for 90Sr/90Y intravascular brachytherapy dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

STRONTIUM 90; YTTRIUM 90;

EID: 0033863191     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/8/319     Document Type: Article
Times cited : (11)

References (13)
  • 2
    • 0008409053 scopus 로고    scopus 로고
    • The EGS4/PRESTA-II electron transport algorithm: test of electron step-size stability XII ICCR (Salt Lake City, UT, 1997)
    • (1997)
    • Bielajew, A.F.1    Kawrakow, I.2
  • 4
    • 0008380153 scopus 로고    scopus 로고
    • PRESTA, the 'parameter reduced electron-step transport algorithm' for electron Monte Carlo transport NRCC Report PIRS-0042 (Ottawa: National Research Council of Canada)
  • 8
    • 84931540072 scopus 로고
    • Theorie der Streuung schneller geladener Teilchen, II. Mehrfach- und Vielfachstreuung Z
    • (1948) Naturf a , vol.3 , pp. 78-97
    • Moliere, V.G.1
  • 9
    • 0032941450 scopus 로고    scopus 로고
    • Intravascular brachytherapy physics: Report of the AAPM radiation therapy committee task group no. 60
    • (1999) Med. Phys , vol.26 , pp. 119-152
    • Nath, R.1