Volumn 25, Issue 9-11, 2003, Pages 1147-1155

MWM eddy-current arrays for crack initiation and growth monitoring

Author keywords

Eddy current; Fatigue damage; Magnetic permeability; MWM

Indexed keywords

CRACK INITIATION; EDDY CURRENTS; ELECTRIC CONDUCTIVITY; MAGNETIC PERMEABILITY; MAGNETOMETERS;

EID: 0242577759     PISSN: 01421123     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijfatigue.2003.08.010     Document Type: Conference Paper
Times cited : (89)

References (19)
  • 5
    • 0021535894 scopus 로고
    • Fatigue damage characterization using X-ray diffraction line analysis
    • Weiss V., Oshida Y. Fatigue damage characterization using X-ray diffraction line analysis. Fatigue. 84:1984;1151.
    • (1984) Fatigue , vol.84 , pp. 1151
    • Weiss, V.1    Oshida, Y.2
  • 6
    • 0242482889 scopus 로고    scopus 로고
    • Fatigue damage detection and micromechanical analysis of 30CrMnSi materials using laser diffraction
    • Gu W., Lu Z., Wang A. Fatigue damage detection and micromechanical analysis of 30CrMnSi materials using laser diffraction. Chinese Journal of Applied Mechanics. 1:1998.
    • (1998) Chinese Journal of Applied Mechanics , vol.1
    • Gu, W.1    Lu, Z.2    Wang, A.3
  • 7
    • 0035206844 scopus 로고    scopus 로고
    • Nonlinear ultrasonic characterization of fatigue microstructures
    • Cantrell J.H. Nonlinear ultrasonic characterization of fatigue microstructures. International Journal of Fatigue. Supplement:2001;S487-S290.
    • (2001) International Journal of Fatigue , vol.SUPPL.
    • Cantrell, J.H.1
  • 12
    • 0001193323 scopus 로고
    • Magnetometers for improved materials characterization in aerospace applications
    • Goldfine N.J. Magnetometers for improved materials characterization in aerospace applications. Materials Evaluation. March:1993;396-405.
    • (1993) Materials Evaluation , vol.MARCH , pp. 396-405
    • Goldfine, N.J.1
  • 14
    • 0035207008 scopus 로고    scopus 로고
    • MWM eddy current sensors for monitoring of crack initiation and growth during fatigue tests and in service
    • Zilberstein V., Schlicker D., Walrath K., Weiss V., Goldfine N. MWM eddy current sensors for monitoring of crack initiation and growth during fatigue tests and in service. International Journal of Fatigue. Supplement:2001;S477-S485.
    • (2001) International Journal of Fatigue , vol.SUPPL. , pp. 477-S485
    • Zilberstein, V.1    Schlicker, D.2    Walrath, K.3    Weiss, V.4    Goldfine, N.5
  • 15
    • 0034774827 scopus 로고    scopus 로고
    • Surface mounted periodic field eddy current sensors for structural health monitoring
    • Kundu T, editor. Smart Structures and Materials, NDE for Health Monitoring and Diagnosis, Newport Beach, CA, 4335
    • Goldfine NJ, Zilberstein V, Schlicker D, Sheiretov Y, Walrath K, Washabaugh A, Van Otterloo D. Surface mounted periodic field eddy current sensors for structural health monitoring. In: Kundu T, editor. Smart Structures and Materials, NDE for Health Monitoring and Diagnosis, SPIE Conference Proceedings, Newport Beach, CA, 4335, 2001. p. 20-34.
    • (2001) SPIE Conference Proceedings , pp. 20-34
    • Goldfine, N.J.1    Zilberstein, V.2    Schlicker, D.3    Sheiretov, Y.4    Walrath, K.5    Washabaugh, A.6    Van Otterloo, D.7