메뉴 건너뛰기




Volumn 85, Issue 6, 2003, Pages 751-758

Problems encountered during the calibration of the new Cameco mobile lung counter: Detector size or phantom limitation?

Author keywords

Calibration; Counting efficiency; Lungs, human; Phantom

Indexed keywords

ALGORITHM; ARTICLE; CALIBRATION; CAMECO MOBILE LUNG COUNTER; DEVICE; DOSIMETRY; INTERMETHOD COMPARISON; LUNG; MEDICAL SOCIETY; PHANTOM; PRIORITY JOURNAL; RADIATION MEASUREMENT; RADIATION PROTECTION; TECHNIQUE;

EID: 0242441570     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-200312000-00021     Document Type: Article
Times cited : (7)

References (15)
  • 3
    • 23544462582 scopus 로고
    • Limits for qualitative detection and quantitative determination: Application to radiochemistry
    • Currie LA. Limits for qualitative detection and quantitative determination: Application to radiochemistry. Anal Chem 40:586-593; 1968.
    • (1968) Anal Chem , vol.40 , pp. 586-593
    • Currie, L.A.1
  • 4
    • 0002629797 scopus 로고
    • Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities
    • Proceedings of an International Atomic Energy Agency Conference. Vienna: IAEA; IAEA-SM-229/56
    • Griffith RV, Dean PN, Anderson AL, Fisher JC. Tissue equivalent torso phantom for intercalibration of in vivo transuranic nuclide counting facilities. In: Advances in radiation monitoring, Proceedings of an International Atomic Energy Agency Conference. Vienna: IAEA; IAEA-SM-229/56; 1978: 4493-4504.
    • (1978) Advances in Radiation Monitoring , pp. 4493-4504
    • Griffith, R.V.1    Dean, P.N.2    Anderson, A.L.3    Fisher, J.C.4
  • 5
    • 0003444170 scopus 로고
    • Oxford: Pergamon Press; ICRP Publication No. 23
    • International Commission on Radiological Protection. Report of the Task Group on Reference Man. Oxford: Pergamon Press; ICRP Publication No. 23; 1975.
    • (1975) Report of the Task Group on Reference Man
  • 7
    • 0031921069 scopus 로고    scopus 로고
    • A joint HML-KAERI project: Comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors
    • Kramer GH, Lee T-Y, Kim J-S. A joint HML-KAERI project: comparison of the LLNL and JAERI torso phantoms using four 50 mm Ge detectors. Health Phys 74:613-618; 1998a.
    • (1998) Health Phys , vol.74 , pp. 613-618
    • Kramer, G.H.1    Lee, T.-Y.2    Kim, J.-S.3
  • 8
    • 0031945491 scopus 로고    scopus 로고
    • Comparison of the LLNL and JAERI torso phantoms using Ge detectors and phoswich detectors
    • Kramer GH, Hauck BM, Allen SA. Comparison of the LLNL and JAERI torso phantoms using Ge detectors and phoswich detectors. Health Phys 74:594-601; 1998b.
    • (1998) Health Phys , vol.74 , pp. 594-601
    • Kramer, G.H.1    Hauck, B.M.2    Allen, S.A.3
  • 9
    • 0028284358 scopus 로고
    • The Canadian National Calibration Reference Centre for Bioassay and In-Vivo Monitoring: A program summary
    • Kramer GH, Limson Zamora M. The Canadian National Calibration Reference Centre for Bioassay and In-Vivo Monitoring: A program summary. Health Phys 67:192-196; 1994.
    • (1994) Health Phys , vol.67 , pp. 192-196
    • Kramer, G.H.1    Limson Zamora, M.2
  • 10
    • 0032996140 scopus 로고    scopus 로고
    • The effect of lung deposition patterns on the activity estimate obtained from a large area germanium detector lung counter
    • Kramer GH, Hauck BM. The effect of lung deposition patterns on the activity estimate obtained from a large area germanium detector lung counter. Health Phys 77:24-32; 1999.
    • (1999) Health Phys , vol.77 , pp. 24-32
    • Kramer, G.H.1    Hauck, B.M.2
  • 11
    • 0035190301 scopus 로고    scopus 로고
    • Chest wall thickness measurements and the dosimetric implications for male workers in the uranium industry
    • Kramer GH, Hauck BM, Allen SA. Chest wall thickness measurements and the dosimetric implications for male workers in the uranium industry. Health Phys 80:74-80; 2001.
    • (2001) Health Phys , vol.80 , pp. 74-80
    • Kramer, G.H.1    Hauck, B.M.2    Allen, S.A.3
  • 13
    • 0024105319 scopus 로고
    • Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities
    • Shirotani T. Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities. J Nucl Sci Tech 25:875-883; 1988.
    • (1988) J Nucl Sci Tech , vol.25 , pp. 875-883
    • Shirotani, T.1
  • 14
    • 0141452228 scopus 로고    scopus 로고
    • Use of group monitoring data in lung dose estimation for intakes of uranium
    • Oxford, UK, Sept 9-12, 2002. Rad Prot Dosim
    • Takala J, Kramer GH. Use of group monitoring data in lung dose estimation for intakes of uranium. In: Proceedings of the Internal Dosimetry Workshop, Oxford, UK, Sept 9-12, 2002. Rad Prot Dosim 105:409-412; 2003.
    • (2003) Proceedings of the Internal Dosimetry Workshop , vol.105 , pp. 409-412
    • Takala, J.1    Kramer, G.H.2
  • 15
    • 0035199842 scopus 로고    scopus 로고
    • An evaluation of Germanium detectors employed for the measurement of radionuclides deposited in the lung using an experimental and Monte Carlo approach
    • Webb JL, Kramer GH. An evaluation of Germanium detectors employed for the measurement of radionuclides deposited in the lung using an experimental and Monte Carlo approach. Health Phys 81:711-719; 2001.
    • (2001) Health Phys , vol.81 , pp. 711-719
    • Webb, J.L.1    Kramer, G.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.