Volumn 74, Issue 5, 1998, Pages 594-601

Comparison of the LLNL and JAERI torso phantoms using ge detectors and phoswich detectors

Author keywords

Calibration; Counting efficiency; Detector; Germanium; Phantom

Indexed keywords

AMERICIUM 241; EUROPIUM; GERMANIUM;

EID: 0031945491     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199805000-00007     Document Type: Article
Times cited : (23)

References (10)
  • 3
    • 0003682469 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement
    • Bethseda, MD: ICRU
    • International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurement. Bethseda, MD: ICRU; ICRU Report No. 44; 1989.
    • (1989) ICRU Report No. 44 , vol.44
  • 4
    • 0026317607 scopus 로고
    • A summary of the Proceedings of the Workshop on Standard Phantoms for in vivo Radioactivity Measurement
    • Kramer, G. H.; Inn, K. G. W. A summary of the Proceedings of the Workshop on Standard Phantoms for in vivo Radioactivity Measurement. Health Phys. 61:893-894; 1991.
    • (1991) Health Phys. , vol.61 , pp. 893-894
    • Kramer, G.H.1    Inn, K.G.W.2
  • 5
    • 0026753101 scopus 로고
    • Evaluation of the Lawrence Livermore National Laboratory (LLNL) torso phantom by bone densitometry and x ray
    • Kramer, G. H.; Webber, C. E. Evaluation of the Lawrence Livermore National Laboratory (LLNL) torso phantom by bone densitometry and x ray. Appl. Radiat. Isot. 43:795-800; 1992.
    • (1992) Appl. Radiat. Isot. , vol.43 , pp. 795-800
    • Kramer, G.H.1    Webber, C.E.2
  • 6
    • 0028284358 scopus 로고
    • The Canadian National Calibration Reference Centre for Bioassay and in Vivo Monitoring: A program summary
    • Kramer, G. H.; Limson Zamora, M. The Canadian National Calibration Reference Centre for Bioassay and In Vivo Monitoring: a program summary. Health Phys. 67:192-196; 1994.
    • (1994) Health Phys. , vol.67 , pp. 192-196
    • Kramer, G.H.1    Limson Zamora, M.2
  • 7
    • 0030746961 scopus 로고    scopus 로고
    • Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting
    • Kramer, G. H.; Hauck, B. M. Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium counting. Health Phys. 73:1-7; 1997.
    • (1997) Health Phys. , vol.73 , pp. 1-7
    • Kramer, G.H.1    Hauck, B.M.2
  • 9
    • 0024105319 scopus 로고
    • Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities
    • Shirotani, T. Realistic torso phantom for calibration of in vivo transuranic-nuclide counting facilities. J. Nucl Sci. Tech. 25:875-883; 1988.
    • (1988) J. Nucl Sci. Tech. , vol.25 , pp. 875-883
    • Shirotani, T.1
  • 10
    • 0018361004 scopus 로고
    • Reference Japanese man I - Mass of organs and other characteristics of normal Japanese
    • Tanaka, G.; Kawamura, H.; Nakahara, Y. Reference Japanese man I - mass of organs and other characteristics of normal Japanese. Health Phys. 36:333-346; 1979.
    • (1979) Health Phys. , vol.36 , pp. 333-346
    • Tanaka, G.1    Kawamura, H.2    Nakahara, Y.3