메뉴 건너뛰기




Volumn 31, Issue 7, 2003, Pages 405-409

Effect of an infection control program using education and performance feedback on rates of intravascular device-associated bloodstream infections in intensive care units in Argentina

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARGENTINA; ARTICLE; CATHETER INFECTION; CONTROLLED STUDY; EDUCATION PROGRAM; FEMALE; HEALTH EDUCATION; HOSPITAL INFECTION; HUMAN; INFECTION CONTROL; MAJOR CLINICAL STUDY; MALE; MENTAL COMPLIANCE; PRACTICE GUIDELINE; VASCULAR ACCESS;

EID: 0242440171     PISSN: 01966553     EISSN: None     Source Type: Journal    
DOI: 10.1067/mic.2003.52     Document Type: Article
Times cited : (149)

References (22)
  • 1
    • 0000381394 scopus 로고    scopus 로고
    • The role of intravascular devices in sepsis
    • Crnich CJ, Maki DG. The role of intravascular devices in sepsis. Curr Infect Dis Rep 2001;3:496-506.
    • (2001) Curr Infect Dis Rep , vol.3 , pp. 496-506
    • Crnich, C.J.1    Maki, D.G.2
  • 2
    • 0024579205 scopus 로고
    • Risk factors for nosocomial infection in intensive care: 'Devices vs nature' and goals for the next decade
    • Maki DG. Risk factors for nosocomial infection in intensive care: 'devices vs nature' and goals for the next decade. Arch Intern Med 1989;149:30-5.
    • (1989) Arch Intern Med , vol.149 , pp. 30-35
    • Maki, D.G.1
  • 3
    • 0011146695 scopus 로고    scopus 로고
    • Nosocomial infections in the intensive care unit associated with invasive medical devices
    • Safdar N, Crnich CJ, Maki DG. Nosocomial infections in the intensive care unit associated with invasive medical devices. Curr Infect Dis Rep 2001;3:487-95.
    • (2001) Curr Infect Dis Rep , vol.3 , pp. 487-495
    • Safdar, N.1    Crnich, C.J.2    Maki, D.G.3
  • 4
    • 0036569749 scopus 로고    scopus 로고
    • The promise of novel technology for the prevention of intravascular device-related bloodstream infection: I, pathogenesis and short-term devices
    • Crnich CJ, Maki DG. The promise of novel technology for the prevention of intravascular device-related bloodstream infection: I, pathogenesis and short-term devices. Clin Infect Dis 2002;34:1232-42.
    • (2002) Clin Infect Dis , vol.34 , pp. 1232-1242
    • Crnich, C.J.1    Maki, D.G.2
  • 6
    • 0032843745 scopus 로고    scopus 로고
    • The attributable mortality and costs of primary nosocomial bloodstream infections in the intensive care unit
    • Digiovine B, Chenoweth C, Watts C, Higgins M. The attributable mortality and costs of primary nosocomial bloodstream infections in the intensive care unit. Am J Respir Crit Care Med 1999;160:976-81.
    • (1999) Am J Respir Crit Care Med , vol.160 , pp. 976-981
    • Digiovine, B.1    Chenoweth, C.2    Watts, C.3    Higgins, M.4
  • 7
    • 0028241340 scopus 로고
    • Nosocomial bloodstream infection in critically ill patients: Excess length of stay, extra costs, and attributable mortality
    • Pittet D, Tarara D, Wenzel RP. Nosocomial bloodstream infection in critically ill patients: excess length of stay, extra costs, and attributable mortality. JAMA 1994;271:1598-601.
    • (1994) JAMA , vol.271 , pp. 1598-1601
    • Pittet, D.1    Tarara, D.2    Wenzel, R.P.3
  • 8
    • 0028123053 scopus 로고
    • Intravascular catheter associated sepsis: A common problem, the Australian study on intravascular catheter associated sepsis
    • Collignon PJ. Intravascular catheter associated sepsis: a common problem, the Australian study on intravascular catheter associated sepsis. Med J Aust 1994;161:374-8.
    • (1994) Med J Aust , vol.161 , pp. 374-378
    • Collignon, P.J.1
  • 9
    • 0000687647 scopus 로고    scopus 로고
    • Guideline for prevention of intravascular device-related infections: Part I, intravascular device-related infections, an overview; the hospital infection control practices advisory committee
    • Pearson ML. Guideline for prevention of intravascular device-related infections: part I, intravascular device-related infections, an overview; the hospital infection control practices advisory committee. Am J Infect Control 1996;24:262-77.
    • (1996) Am J Infect Control , vol.24 , pp. 262-277
    • Pearson, M.L.1
  • 10
    • 0031992914 scopus 로고    scopus 로고
    • Requirements for infrastructure and essential activities of infection control and epidemiology in hospitals: A consensus panel report; society for healthcare epidemiology of America
    • Scheckler WE, Brimhall D, Buck AS, Farr BM, Friedman C, Garibaldi RA, et al. Requirements for infrastructure and essential activities of infection control and epidemiology in hospitals: a consensus panel report; society for healthcare epidemiology of America. Infect Control Hosp Epidemiol 1998;19:114-24.
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 114-124
    • Scheckler, W.E.1    Brimhall, D.2    Buck, A.S.3    Farr, B.M.4    Friedman, C.5    Garibaldi, R.A.6
  • 12
    • 0017734445 scopus 로고
    • A semiquantitative culture method for identifying intravenous-catheter- related infection
    • Maki DG, Weise CE, Sarafin HW. A semiquantitative culture method for identifying intravenous-catheter-related infection. N Engl J Med 1977;296:1305-9.
    • (1977) N Engl J Med , vol.296 , pp. 1305-1309
    • Maki, D.G.1    Weise, C.E.2    Sarafin, H.W.3
  • 13
    • 33646672052 scopus 로고    scopus 로고
    • National Committee for Clinical Laboratory Standards (NCCLS) M7-A4. Washington, DC: National Committee for Clinical Laboratory Standards
    • Villanova P. National Committee for Clinical Laboratory Standards (NCCLS). Minimum inhibitory concentration interpretive standards. M7-A4. Vol. Document 2. Washington, DC: National Committee for Clinical Laboratory Standards; 1997.
    • (1997) Minimum Inhibitory Concentration Interpretive Standards , vol.2 VOL. DOCUMENT
    • Villanova, P.1
  • 16
    • 0034090864 scopus 로고    scopus 로고
    • Prevention of intravascular catheter-related infections
    • Mermel LA. Prevention of intravascular catheter-related infections. Ann Intern Med 2000;132:391-402.
    • (2000) Ann Intern Med , vol.132 , pp. 391-402
    • Mermel, L.A.1
  • 17
    • 0000082718 scopus 로고    scopus 로고
    • Infections due to infusion therapy
    • Bennett JV, Brachman PS. Philadelphia: Lippincott-Raven
    • Maki D, Mermel L. Infections due to infusion therapy. In: Bennett JV, Brachman PS. Hospital infections. 4th ed. Philadelphia: Lippincott-Raven; 1998. p. 689-724.
    • (1998) Hospital Infections. 4th Ed. , pp. 689-724
    • Maki, D.1    Mermel, L.2
  • 19
    • 0028412059 scopus 로고
    • Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion
    • Raad II, Hohn DC, Gilbreath BJ, Suleiman N, Hill LA, Bruso PA, et al. Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion. Infect Control Hosp Epidemiol 1994;15:231-8.
    • (1994) Infect Control Hosp Epidemiol , vol.15 , pp. 231-238
    • Raad, I.I.1    Hohn, D.C.2    Gilbreath, B.J.3    Suleiman, N.4    Hill, L.A.5    Bruso, P.A.6
  • 20
    • 0025825996 scopus 로고
    • Prospective randomized trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters
    • Maki DG, Ringer M, Alvarado CJ. Prospective randomized trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters. Lancet 1991;338:339-43.
    • (1991) Lancet , vol.338 , pp. 339-343
    • Maki, D.G.1    Ringer, M.2    Alvarado, C.J.3
  • 21
    • 0030791566 scopus 로고    scopus 로고
    • Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter: A randomized, controlled trial
    • Maki DG, Stolz SM, Wheeler S, Mermel LA. Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter: a randomized, controlled trial. Ann Intern Med 1997;127:257-66.
    • (1997) Ann Intern Med , vol.127 , pp. 257-266
    • Maki, D.G.1    Stolz, S.M.2    Wheeler, S.3    Mermel, L.A.4
  • 22
    • 0030753776 scopus 로고    scopus 로고
    • Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections: A randomized, double-blind trial; the Texas medical center catheter study group
    • Raad I, Darouiche R, Dupuis J, Abi-Said D, Gabrielli A, Hachem R, et al. Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections: a randomized, double-blind trial; the Texas medical center catheter study group. Ann Intern Med 1997;127:267-74.
    • (1997) Ann Intern Med , vol.127 , pp. 267-274
    • Raad, I.1    Darouiche, R.2    Dupuis, J.3    Abi-Said, D.4    Gabrielli, A.5    Hachem, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.