메뉴 건너뛰기




Volumn 50, Issue 5, 2003, Pages 1095-1099

Radial Alternating TE Sequence for Faster Fat Suppression

Author keywords

Dixon methods; Fat suppression; Radial acquisition; Rapid MRI

Indexed keywords

OPTICAL TRANSFER FUNCTION; SPACE FLIGHT;

EID: 0242353934     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10615     Document Type: Article
Times cited : (9)

References (15)
  • 2
    • 0031877407 scopus 로고    scopus 로고
    • Simultaneous highly selective MR water and fat imaging using a simple new type of spectral-spatial excitation
    • Schick F. Simultaneous highly selective MR water and fat imaging using a simple new type of spectral-spatial excitation. Magn Reson Med 1998;40:194-202.
    • (1998) Magn Reson Med , vol.40 , pp. 194-202
    • Schick, F.1
  • 4
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153:189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 5
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1:521-530.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521-530
    • Glover, G.H.1
  • 7
    • 0035180571 scopus 로고    scopus 로고
    • Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout
    • Larson AC, Simonetti OP. Real-time cardiac cine imaging with SPIDER: steady-state projection imaging with dynamic echo-train readout. Magn Reson Med 2001;46:1059-1066.
    • (2001) Magn Reson Med , vol.46 , pp. 1059-1066
    • Larson, A.C.1    Simonetti, O.P.2
  • 8
    • 0031195397 scopus 로고    scopus 로고
    • Multishot rosette trajectories for spectrally selective MR imaging
    • Noll DC. Multishot rosette trajectories for spectrally selective MR imaging. IEEE Trans Med Imaging 1997;16:372-377.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 372-377
    • Noll, D.C.1
  • 9
    • 0035263304 scopus 로고    scopus 로고
    • A rapid look-up table method for reconstructing MR images from arbitrary k-space trajectories
    • Dale BM, Wendt M, Duerk JL. A rapid look-up table method for reconstructing MR images from arbitrary k-space trajectories. IEEE Trans Med Imaging 2001;20:207-217.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 207-217
    • Dale, B.M.1    Wendt, M.2    Duerk, J.L.3
  • 10
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method for k-space trajectory deviations in MRI
    • Duyn JH, Yang Y, Frank JA, van der Veen JW. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 1998;132:150-153.
    • (1998) J Magn Reson , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Van der Veen, J.W.4
  • 11
    • 0029956707 scopus 로고    scopus 로고
    • Effects of polar sampling in k-space
    • Lauzon ML, Rutt BK. Effects of polar sampling in k-space. Magn Reson Med 1996;36:940-949.
    • (1996) Magn Reson Med , vol.36 , pp. 940-949
    • Lauzon, M.L.1    Rutt, B.K.2
  • 13
    • 0035186327 scopus 로고    scopus 로고
    • Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: Fast accurate gridding with noise and artifact reduction
    • Moriguchi H, Duerk JL. Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: fast accurate gridding with noise and artifact reduction. Magn Reson Med 2001;46:1189-1201.
    • (2001) Magn Reson Med , vol.46 , pp. 1189-1201
    • Moriguchi, H.1    Duerk, J.L.2
  • 14
  • 15
    • 0034199949 scopus 로고    scopus 로고
    • High-resolution diffusion imaging using a radial turbo-spin-echo sequence: Implementation, eddy current compensation, and self-navigation
    • Seifert MH, Jakob PM, Jellus V, Haase A, Hillenbrand C. High-resolution diffusion imaging using a radial turbo-spin-echo sequence: implementation, eddy current compensation, and self-navigation. J Magn Reson 2000;144:243-254.
    • (2000) J Magn Reson , vol.144 , pp. 243-254
    • Seifert, M.H.1    Jakob, P.M.2    Jellus, V.3    Haase, A.4    Hillenbrand, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.