메뉴 건너뛰기




Volumn 28, Issue 20 SUPPL., 2003, Pages

Experimental design of total disk replacement - Experience with a prospective randomized study of the SB Charitè

Author keywords

Lumbar disc replacement; Prospective randomized trial; SB Charit prosthesis; Spinal arthroplasty

Indexed keywords

ADULT; ANTERIOR SPINE FUSION; ARTHROPLASTY; ARTICLE; BIOMECHANICS; BLEEDING; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DECOMPRESSION SURGERY; DISABILITY; DISKOGRAPHY; FEMALE; FOLLOW UP; HUMAN; INTERVERTEBRAL DISK DEGENERATION; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OPERATION DURATION; PRIORITY JOURNAL; PROSTHESIS; RANDOMIZED CONTROLLED TRIAL; SPINE RADIOGRAPHY; VERTEBRAL CANAL STENOSIS;

EID: 0142121541     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.brs.0000092217.34981.e1     Document Type: Article
Times cited : (48)

References (25)
  • 2
    • 0031000796 scopus 로고    scopus 로고
    • Intervertebral disc prosthesis. Results and prospects for the year 2000
    • Lemaire JP, Shalli W, Laveste F, et al. Intervertebral disc prosthesis. Results and prospects for the year 2000. Clin Orthop 1997;337:64-76.
    • (1997) Clin Orthop , vol.337 , pp. 64-76
    • Lemaire, J.P.1    Shalli, W.2    Laveste, F.3
  • 3
    • 0036605458 scopus 로고    scopus 로고
    • Chronic low back pain and fusion: A comparison of three surgical techniques. A prospective multicenter randomized study from the Swedish Lumbar spine study group
    • Fritzell P, Hagg O, Wessberg P, et al. Chronic low back pain and fusion: a comparison of three surgical techniques. A prospective multicenter randomized study from the Swedish Lumbar spine study group. Spine 2002;27:1131-41.
    • (2002) Spine , vol.27 , pp. 1131-1141
    • Fritzell, P.1    Hagg, O.2    Wessberg, P.3
  • 4
    • 0029871625 scopus 로고    scopus 로고
    • Results of the disc prosthesis after a minimum follow-up period of 2 years
    • Cinotti G, David T, Postacchini F. Results of the disc prosthesis after a minimum follow-up period of 2 years. Spine 1996;8:995-1000.
    • (1996) Spine , vol.8 , pp. 995-1000
    • Cinotti, G.1    David, T.2    Postacchini, F.3
  • 5
    • 0028132196 scopus 로고
    • A multicenter retrospective study of the clinical results of the Link SB Charitè intervertebral prosthesis. The initial European experience
    • Griffith SL, Shelokov AP, Buttner-Janz K, et al, A multicenter retrospective study of the clinical results of the Link SB Charitè intervertebral prosthesis. The initial European experience. Spine 1994;19:1842-9.
    • (1994) Spine , vol.19 , pp. 1842-1849
    • Griffith, S.L.1    Shelokov, A.P.2    Buttner-Janz, K.3
  • 6
    • 0033024784 scopus 로고    scopus 로고
    • Artificial disc replacement with the modular type SB Charitè III. 2 Year results in 50 prospectively studied patients
    • Zeegers WS, Bohen LMLJ, Laaper M, et al. Artificial disc replacement with the modular type SB Charitè III. 2 year results in 50 prospectively studied patients. Eur Spine J 1999;8:210-7.
    • (1999) Eur Spine J , vol.8 , pp. 210-217
    • Zeegers, W.S.1    Bohen, L.M.L.J.2    Laaper, M.3
  • 7
    • 0043044317 scopus 로고    scopus 로고
    • Artificial disc prosthesis
    • The Link SB Charitè. Kaech DL, Jinkins JR, eds. Elsevier Science B.V.
    • McAfee, PC. Artificial disc prosthesis. The Link SB Charitè, in Spinal Restabilization Procedures. Kaech DL, Jinkins JR, eds. Elsevier Science B.V.; 2002:299-310.
    • (2002) Spinal Restabilization Procedures , pp. 299-310
    • McAfee, P.C.1
  • 8
    • 0036141185 scopus 로고    scopus 로고
    • Anterior BAK instrumentation and fusion: Complete versus partial diskectomy
    • McAfee PC, Lee GA, Fedder IL, et al. Anterior BAK instrumentation and fusion: complete versus partial diskectomy. Clin Orthop 2002;389:55-63.
    • (2002) Clin Orthop , vol.389 , pp. 55-63
    • McAfee, P.C.1    Lee, G.A.2    Fedder, I.L.3
  • 9
    • 0022505460 scopus 로고
    • Centrode characteristics of the lumbar spine as a function of segmental instability
    • Gertzbein SD, Seligman J, Holtby R, et al. Centrode characteristics of the lumbar spine as a function of segmental instability. Clin Orthop 1986;208:48-51.
    • (1986) Clin Orthop , vol.208 , pp. 48-51
    • Gertzbein, S.D.1    Seligman, J.2    Holtby, R.3
  • 10
    • 0032101704 scopus 로고    scopus 로고
    • The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow up results of a United States prospective, multicenter trial
    • Kuslich SD, Ulstrom CL, Griffith SL, et al. The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow up results of a United States prospective, multicenter trial. Spine 1998;23:1267-78.
    • (1998) Spine , vol.23 , pp. 1267-1278
    • Kuslich, S.D.1    Ulstrom, C.L.2    Griffith, S.L.3
  • 11
    • 0035252075 scopus 로고    scopus 로고
    • Symposium: A critical discrepancy - A criteria of successful arthrodesis following interbody spinal fusions
    • McAfee PC. Symposium: a critical discrepancy - a criteria of successful arthrodesis following interbody spinal fusions. Spine 2001;26:320-34.
    • (2001) Spine , vol.26 , pp. 320-334
    • McAfee, P.C.1
  • 12
    • 0036842768 scopus 로고    scopus 로고
    • A Comprehensive Study of patients with surgically treated lumbar spinal stenosis with neurogenic claudication
    • Yukawa Y, Lenke LG, Tenhula J, et al. A Comprehensive Study of patients with surgically treated lumbar spinal stenosis with neurogenic claudication. J Bone Joint Surg Am 2002;84A:1954-9.
    • (2002) J Bone Joint Surg Am , vol.84 A , pp. 1954-1959
    • Yukawa, Y.1    Lenke, L.G.2    Tenhula, J.3
  • 13
    • 0042487907 scopus 로고    scopus 로고
    • A prospective randomized study assessing the clinical and radiographic outcomes of patients treated with rhBMP-2 and threaded cortical bone dowels in the lumbar spine
    • New Orleans, Louisiana
    • Burkus JK, Transfeldt E, Kitchell SH, et al. A prospective randomized study assessing the clinical and radiographic outcomes of patients treated with rhBMP-2 and threaded cortical bone dowels in the lumbar spine. Presented at NASS meeting; 2000; New Orleans, Louisiana: 114.
    • (2000) NASS Meeting , pp. 114
    • Burkus, J.K.1    Transfeldt, E.2    Kitchell, S.H.3
  • 14
    • 0037102590 scopus 로고    scopus 로고
    • Use of recombinant human bone morphogenic protein-2 in spinal fusion applications
    • McKay B, Sandu HS. Use of recombinant human bone morphogenic protein-2 in spinal fusion applications. Spine 2002;27:S66-S85.
    • (2002) Spine , vol.27
    • McKay, B.1    Sandu, H.S.2
  • 15
    • 0005637914 scopus 로고    scopus 로고
    • Laparoscopic approach with tapered metal cages: rhBMP-2 vs. autograft
    • Zdeblick TA, Heim SE, Kleeman TJ, et al. Laparoscopic approach with tapered metal cages: rhBMP-2 vs. autograft. Presented at the NASS meeting; 2001:200.
    • (2001) NASS Meeting , pp. 200
    • Zdeblick, T.A.1    Heim, S.E.2    Kleeman, T.J.3
  • 16
    • 0038398790 scopus 로고    scopus 로고
    • Classification of Heterotopic Ossification (HO) in Artificial Disk Replacement
    • Proceedings of the 17th Annual Meeting of the North American Spine Society in Montreal Canada
    • McAfee PC, Cunningham BW, Devine JD, et al. Classification of Heterotopic Ossification (HO) in Artificial Disk Replacement. Proceedings of the 17th Annual Meeting of the North American Spine Society in Montreal Canada. The Spine J 2002;2:94S.
    • (2002) The Spine J , vol.2
    • McAfee, P.C.1    Cunningham, B.W.2    Devine, J.D.3
  • 17
    • 0035906301 scopus 로고    scopus 로고
    • The value of patient flow charts in reports of randomized controlled trials: Bibliographic study
    • Egger M, Juni P, Bartlett C, et al. The value of patient flow charts in reports of randomized controlled trials: bibliographic study. JAMA 2001;285:1996-9.
    • (2001) JAMA , vol.285 , pp. 1996-1999
    • Egger, M.1    Juni, P.2    Bartlett, C.3
  • 18
    • 0005203612 scopus 로고    scopus 로고
    • An analysis of the Acroflex lumbar Disc prosthesis. A non-human primate model
    • November 3; Seattle, Washington
    • Cunningham BW, Lowery GL, Gonzales V, et al. An analysis of the Acroflex lumbar Disc prosthesis. A non-human primate model. Proceedings of the North American Spine Society; November 3, 2001; Seattle, Washington:74-5.
    • (2001) Proceedings of the North American Spine Society , pp. 74-75
    • Cunningham, B.W.1    Lowery, G.L.2    Gonzales, V.3
  • 19
    • 0037442365 scopus 로고    scopus 로고
    • Analysis of porous ingrowth in intervertebral disc prostheses. A non-human primate model
    • McAfee PC, Cunningham BW, Orbegoso CM, et al. Analysis of porous ingrowth in intervertebral disc prostheses. A non-human primate model. Spine 2003;28:332-40.
    • (2003) Spine , vol.28 , pp. 332-340
    • McAfee, P.C.1    Cunningham, B.W.2    Orbegoso, C.M.3
  • 20
    • 0013326201 scopus 로고    scopus 로고
    • Evaluation of BONIT, a fully resorbable CaP coating obtained by electrochemical deposition, after 6 weeks of heating. A pilot study in the pig maxilla
    • Davidovitch Z, Mah J, eds
    • Szmukler-Moncler S, Perin S, Ahossi V, et al. Evaluation of BONIT, a fully resorbable CaP coating obtained by electrochemical deposition, after 6 weeks of heating. A pilot study in the pig maxilla. Biological Mechanisms of Tooth Eruption, Resorption, and Replacements by Implants. Davidovitch Z, Mah J, eds. 1998:481-5.
    • (1998) Biological Mechanisms of Tooth Eruption, Resorption, and Replacements by Implants , pp. 481-485
    • Szmukler-Moncler, S.1    Perin, S.2    Ahossi, V.3
  • 21
    • 0030960089 scopus 로고    scopus 로고
    • Measurement of polyethylene wear in acetabular components inserted with and without cement
    • Devaine PA, Robinson EJ, Bourne RB, et al. Measurement of polyethylene wear in acetabular components inserted with and without cement. J Bone Joint Surg Am 1997;79A:682-9.
    • (1997) J Bone Joint Surg Am , vol.79 A , pp. 682-689
    • Devaine, P.A.1    Robinson, E.J.2    Bourne, R.B.3
  • 22
    • 0036033685 scopus 로고    scopus 로고
    • History, design, and biomechanics of the Link SB Charitè artificial disk
    • Link HD. History, design, and biomechanics of the Link SB Charitè artificial disk. Eur Spine 2002;11:S98-S105.
    • (2002) Eur Spine , vol.11
    • Link, H.D.1
  • 23
    • 0037106124 scopus 로고    scopus 로고
    • The effect of titanium particulate on the development and maintenance of a posterolateral spinal arthrodesis: An in vivo rabbit model
    • Cunningham BW, Orbegoso CM, Dmitriev AE, et al. The effect of titanium particulate on the development and maintenance of a posterolateral spinal arthrodesis: an in vivo rabbit model. Spine 2002;18:1971-81.
    • (2002) Spine , vol.18 , pp. 1971-1981
    • Cunningham, B.W.1    Orbegoso, C.M.2    Dmitriev, A.E.3
  • 24
    • 0042042633 scopus 로고    scopus 로고
    • The effect of spinal instrumentation particulate wear debris: An in vivo rabbit model and applied clinical study of retrieved instrumentation cases
    • Cunningham BW, Orbegoso CM, Dmitriev AE, et al. The effect of spinal instrumentation particulate wear debris: an in vivo rabbit model and applied clinical study of retrieved instrumentation cases. The Spine J 2002;2:69S-70S.
    • (2002) The Spine J , vol.2
    • Cunningham, B.W.1    Orbegoso, C.M.2    Dmitriev, A.E.3
  • 25
    • 0034956403 scopus 로고    scopus 로고
    • Twenty-year evaluation of meniscal bearing and rotating platform knee replacements
    • Buechel FF Sr, Buechel FF Jr, Pappas MJ, et al. Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop 2001;388:41-50.
    • (2001) Clin Orthop , vol.388 , pp. 41-50
    • Buechel F.F., Sr.1    Buechel F.F., Jr.2    Pappas, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.