-
2
-
-
0032585494
-
A new high resolution radioimager for the quantitative analysis of radiolabeled molecules in tissue section
-
P. Laniece, Y. Charon, A. Cardona, L. Pinot, S. Maitrejean, R. Mastrippolito, B. Sandkamp, and L. Valentin, "A new high resolution radioimager for the quantitative analysis of radiolabeled molecules in tissue section," J. Neurosci. Methods, vol. 86, pp. 1-5, 1998.
-
(1998)
J. Neurosci. Methods
, vol.86
, pp. 1-5
-
-
Laniece, P.1
Charon, Y.2
Cardona, A.3
Pinot, L.4
Maitrejean, S.5
Mastrippolito, R.6
Sandkamp, B.7
Valentin, L.8
-
3
-
-
0031169987
-
A 'Bioscope' system using double-sided silicon strip detectors and self-triggering read-out chips
-
M. Overdick, A. Czermak, P. Fischer, K. Herzog, A. Kjensmo, T. Kugelmeier, K. Ljunggren, E. Nygard, C. Pietrzik, T. Schwan, S. E. Strand, P. Weilhammer, N. Wermes, and K. Yoshioka, "A 'Bioscope' system using double-sided silicon strip detectors and self-triggering read-out chips," Nucl. Instrum. Methods A, vol. 392, pp. 173-180, 1997.
-
(1997)
Nucl. Instrum. Methods A
, vol.392
, pp. 173-180
-
-
Overdick, M.1
Czermak, A.2
Fischer, P.3
Herzog, K.4
Kjensmo, A.5
Kugelmeier, T.6
Ljunggren, K.7
Nygard, E.8
Pietrzik, C.9
Schwan, T.10
Strand, S.E.11
Weilhammer, P.12
Wermes, N.13
Yoshioka, K.14
-
4
-
-
0033334586
-
An MCP-based system for beta autoradiography
-
June
-
J. E. Lees, G. W. Fraser, and D. Dinsdale, "An MCP-based system for beta autoradiography," IEEE Tran. Nucl. Sci., vol. 46, pp. 636-638, June 1999.
-
(1999)
IEEE Tran. Nucl. Sci.
, vol.46
, pp. 636-638
-
-
Lees, J.E.1
Fraser, G.W.2
Dinsdale, D.3
-
5
-
-
0029511920
-
A spatially adaptive image restoration for autoradiography
-
G. A. Goyette, M. G. Kang, A. K. Katsaggelos, and G. D. Lapin, "A spatially adaptive image restoration for autoradiography," SPIE, vol. 2622, pp. 811-821.
-
SPIE
, vol.2622
, pp. 811-821
-
-
Goyette, G.A.1
Kang, M.G.2
Katsaggelos, A.K.3
Lapin, G.D.4
-
6
-
-
0028484433
-
Improving autoradiograph resolution using image restoration techniques
-
Aug./Sept.
-
G. A. Goyette, G. D. Lapin, M. G. Kang, and A. K. Katsaggelos, "Improving autoradiograph resolution using image restoration techniques," IEEE Eng. Med. Biol., pp. 571-574, Aug./Sept. 1994.
-
(1994)
IEEE Eng. Med. Biol.
, pp. 571-574
-
-
Goyette, G.A.1
Lapin, G.D.2
Kang, M.G.3
Katsaggelos, A.K.4
-
7
-
-
0033930192
-
The performance of a CCD digital autoradiography imaging system
-
R. J. Ott, J. H. MacDonald, and K. Wells, "The performance of a CCD digital autoradiography imaging system," Phys. Med. Biol., vol. 45, pp. 2011-2027, 2000.
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 2011-2027
-
-
Ott, R.J.1
MacDonald, J.H.2
Wells, K.3
-
9
-
-
0142031319
-
-
Patent applicat. #GB0225819.2
-
Patent applicat. #GB0225819.2.
-
-
-
|