Volumn 30, Issue 10, 2003, Pages 2638-2642

Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography

Author keywords

Average photon energy; Beam quality; Half value layer; Mammography; X ray spectrum

Indexed keywords

BEAM QUALITY; MAMMOGRAPHY; PHOTONS; X RAY SPECTROGRAPHS; X RAYS;

EID: 0142057579     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1608498     Document Type: Article
Times cited : (15)

References (12)
  • 1
    • 0030822878 scopus 로고    scopus 로고
    • Comparison of exposure standards in the mammography x-ray region
    • J.G. Coletti, D.W. Pearson, L.A. DeWerd, C.M. O'Brien, and P.J. Lamperti, "Comparison of exposure standards in the mammography x-ray region," Med. Phys. 24, 1263-1267 (1997); http://physics.nist.gov/Divisions/Div846/Gp2/tab87.html
    • (1997) Med. Phys. , vol.24 , pp. 1263-1267
    • Coletti, J.G.1    Pearson, D.W.2    DeWerd, L.A.3    O'Brien, C.M.4    Lamperti, P.J.5
  • 2
    • 0002977248 scopus 로고    scopus 로고
    • Standards for radiation protection and diagnostic radiology at the IAEA dosimetry laboratory
    • F. Pernièka, P. Andreo, A. Meghziefene, L. Czap, and R. Girzikowsky, "Standards for radiation protection and diagnostic radiology at the IAEA dosimetry laboratory," SSDL Newsletter, 17 (1999); http://www-pub.iaea.org/MTCD/publication/newsletter.asp.
    • (1999) SSDL Newsletter , pp. 17
    • Pernièka, F.1    Andreo, P.2    Meghziefene, A.3    Czap, L.4    Girzikowsky, R.5
  • 3
    • 85001545306 scopus 로고    scopus 로고
    • The Netherlands Metrology Institute Van Swinden Laboratorium (NMi), "Radiation Qualities 10 kV -320 kV X-rays," http://www.nmi.nl/english/science_calibration/radiation.htm
    • Radiation Qualities 10 kV -320 kV X-rays
  • 4
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • J.M. Boone, T.R. Fewell, and R.J. Jennings, "Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography," Med. Phys. 24, 1863-1874 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 5
    • 0030938882 scopus 로고    scopus 로고
    • Parametrization of mammography normalized average glandular dose tables
    • W.T. Sobol and X. Wu, "Parametrization of mammography normalized average glandular dose tables," Med. Phys. 24, 547-554 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 547-554
    • Sobol, W.T.1    Wu, X.2
  • 6
    • 0027956991 scopus 로고
    • Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography
    • X. Wu, E.L. Gingold, G.T. Barnes, and D.M. Tucker, "Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography," Radiology 193, 83-89 (1994).
    • (1994) Radiology , vol.193 , pp. 83-89
    • Wu, X.1    Gingold, E.L.2    Barnes, G.T.3    Tucker, D.M.4
  • 7
    • 0035011178 scopus 로고    scopus 로고
    • A comparison of mammography spectral measurements with spectra produced using several different mathematical models
    • E. Wilkinson, P.N. Johnston, and J.C. Heggie, "A comparison of mammography spectral measurements with spectra produced using several different mathematical models," Phys. Med. Biol. 46, 1575-1589 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1575-1589
    • Wilkinson, E.1    Johnston, P.N.2    Heggie, J.C.3
  • 8
    • 0003966099 scopus 로고
    • XCOM: Photon cross sections database on a personal computer
    • M.J. Berger, J.H. Hubbell, and S.M. Seltzer, "XCOM: Photon cross sections database on a personal computer," NBSIR 87-3597, 1987.
    • (1987) NBSIR , pp. 87-3597
    • Berger, M.J.1    Hubbell, J.H.2    Seltzer, S.M.3
  • 10
    • 0033941050 scopus 로고    scopus 로고
    • Design optimization of breast imaging system based on silicom microstrip detectors
    • S. Stres, T. Mali, M. Mikuz, and V. Cindro, "Design optimization of breast imaging system based on silicom microstrip detectors," Phys. Med. Biol. 45, 395-404 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 395-404
    • Stres, S.1    Mali, T.2    Mikuz, M.3    Cindro, V.4
  • 12
    • 0035999415 scopus 로고    scopus 로고
    • Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data
    • J.M. Boone, "Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data," Med. Phys. 29, 869-875 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 869-875
    • Boone, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.