-
1
-
-
78651036121
-
Application of a mechanical heart and lung apparatus to cardiac surgery
-
Gibbon JH Jr. Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med 1954; 37: 171.
-
(1954)
Minn. Med.
, vol.37
, pp. 171
-
-
Gibbon Jr., J.H.1
-
2
-
-
0002833301
-
Immobilisation of macromolecules for obtaining biocompatible surfaces
-
Sleytr UB, Meissner P, Pum D eds. London: Springer
-
Courtney JM, Sundaram S. Immobilisation of macromolecules for obtaining biocompatible surfaces. In Sleytr UB, Meissner P, Pum D eds. Immobilised macromolecules: application potential. London: Springer, 1993: 175-94.
-
(1993)
Immobilised Macromolecules: Application Potential
, pp. 175-194
-
-
Courtney, J.M.1
Sundaram, S.2
-
3
-
-
0141989274
-
Size is at the heart of the matter: Update on advanced circulatory support technology
-
Mongero LB. Size is at the heart of the matter: update on advanced circulatory support technology. Heart Surg Forum 2003; 6: 112-13.
-
(2003)
Heart Surg. Forum.
, vol.6
, pp. 112-113
-
-
Mongero, L.B.1
-
4
-
-
0036223007
-
A new concept of integrated cardiopulmonary bypass circuit
-
Mueller XM, Jegger D, Augstburger M, Horisberger J, Godar G, von Segesser LK. A new concept of integrated cardiopulmonary bypass circuit. Eur J Cardiothorac Surg 2002; 21: 840-46.
-
(2002)
Eur. J. Cardiothorac. Surg.
, vol.21
, pp. 840-846
-
-
Mueller, X.M.1
Jegger, D.2
Augstburger, M.3
Horisberger, J.4
Godar, G.5
von Segesser, L.K.6
-
5
-
-
0019418860
-
Complement activation during cardiopulmonary bypass: Evidence for generation of C3a and C5a anaphylatoxins
-
Chenoweth DE, Cooper SW, Hugli TE, Stewart RW, Blackstone EH, Kirklin JW. Complement activation during cardiopulmonary bypass: evidence for generation of C3a and C5a anaphylatoxins. New Engl J Med 1981; 304: 497-503.
-
(1981)
New Engl. J. Med.
, vol.304
, pp. 497-503
-
-
Chenoweth, D.E.1
Cooper, S.W.2
Hugli, T.E.3
Stewart, R.W.4
Blackstone, E.H.5
Kirklin, J.W.6
-
6
-
-
0021051610
-
Complement and the damaging effects of cardiopulmonary bypass
-
Kirklin JK, Westaby S, Blackstone EH, Kirklin JW, Chenoweth DE, Pacifico AD. Complement and the damaging effects of cardiopulmonary bypass. J Thorac Cardiovasc Surg 1983; 86: 845-47.
-
(1983)
J. Thorac. Cardiovasc. Surg.
, vol.86
, pp. 845-847
-
-
Kirklin, J.K.1
Westaby, S.2
Blackstone, E.H.3
Kirklin, J.W.4
Chenoweth, D.E.5
Pacifico, A.D.6
-
8
-
-
37049246701
-
Heparin bonding on colloidal graphite surfaces
-
Gott VL, Whiffen JO et al. Heparin bonding on colloidal graphite surfaces. Science 1963; 142: 1297-98.
-
(1963)
Science
, vol.142
, pp. 1297-1298
-
-
Gott, V.L.1
Whiffen, J.O.2
-
9
-
-
0027156091
-
Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass
-
Gu YJ, van Oeveren W, Akkerman C, Boonstra PW, Huyzen RJ, Wildeuvur CR. Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 1993; 55: 912-22.
-
(1993)
Ann. Thorac. Surg.
, vol.55
, pp. 912-922
-
-
Gu, Y.J.1
van Oeveren, W.2
Akkerman, C.3
Boonstra, P.W.4
Huyzen, R.J.5
Wildeuvur, C.R.6
-
10
-
-
0034041743
-
Heparin coated CPB circuits reduce circulating complement factors and IL6 in paediatric patients
-
Olsson C, Seigbahn A, Henze A et al. Heparin coated CPB circuits reduce circulating complement factors and IL6 in paediatric patients. Scand Cardiovasc J 2000; 34: 33-40.
-
(2000)
Scand. Cardiovasc. J.
, vol.34
, pp. 33-40
-
-
Olsson, C.1
Seigbahn, A.2
Henze, A.3
-
11
-
-
0034055782
-
Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration
-
DeFragne JO, Pincemail J, Larbuisson R, Blaffart F, Linnet R. Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration. Ann Thorac Surg 2000; 69: 1084-91.
-
(2000)
Ann. Thorac. Surg.
, vol.69
, pp. 1084-1091
-
-
DeFragne, J.O.1
Pincemail, J.2
Larbuisson, R.3
Blaffart, F.4
Linnet, R.5
-
12
-
-
0036302175
-
Duraflo II bonding does not attenuate cytokine release or improve pulmonary function
-
Butler J, Marithi EW, Pathi VL, MacArthur KJ, Berg GA. Duraflo II bonding does not attenuate cytokine release or improve pulmonary function. Ann Thorac Surg 2002; 74: 139-42.
-
(2002)
Ann. Thorac. Surg.
, vol.74
, pp. 139-142
-
-
Butler, J.1
Marithi, E.W.2
Pathi, V.L.3
MacArthur, K.J.4
Berg, G.A.5
-
13
-
-
0034783119
-
Biocompatibility of Trillium Biopassive Surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass
-
discussion 539-41
-
Ereth MH, Nuttall GA, Clarke SH et al. Biocompatibility of Trillium Biopassive Surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass. J Cardiothorac Vasc Anaesth 2001; 15: 545-50: discussion 539-41.
-
(2001)
J. Cardiothorac. Vasc. Anaesth.
, vol.15
, pp. 545-550
-
-
Ereth, M.H.1
Nuttall, G.A.2
Clarke, S.H.3
-
14
-
-
0036376782
-
Effects of two differently heparin-coated extracorporeal circuits on markers for brain and myocardial dysfunction
-
Flom-Halvorsen HI, Ovrum E, Brosstad F, Tangen G, Ringdal M, Oystese R. Effects of two differently heparin-coated extracorporeal circuits on markers for brain and myocardial dysfunction. Perfusion 2002; 17: 339-45.
-
(2002)
Perfusion
, vol.17
, pp. 339-345
-
-
Flom-Halvorsen, H.I.1
Ovrum, E.2
Brosstad, F.3
Tangen, G.4
Ringdal, M.5
Oystese, R.6
-
15
-
-
0032930718
-
Influence on blood of plasticized polyvinyl chloride: Significance of the plasticizer
-
Zhao X, Courtney JM. Influence on blood of plasticized polyvinyl chloride: significance of the plasticizer. Artif Organs 1999; 23: 104-107.
-
(1999)
Artif. Organs
, vol.23
, pp. 104-107
-
-
Zhao, X.1
Courtney, J.M.2
-
16
-
-
0141954581
-
Blood-surface interface
-
Gravlee GP, Davis RF, Kurusz M, Utley JR eds. Philadelphia, PA, USA: Lippincott Williams and Wilkins
-
Edmunds LH. Blood-surface interface. In Gravlee GP, Davis RF, Kurusz M, Utley JR eds. Cardiopulmonary bypass: principles and practice. Philadelphia, PA, USA: Lippincott Williams and Wilkins, 2002.
-
(2002)
Cardiopulmonary Bypass: Principles and Practice
-
-
Edmunds, L.H.1
-
17
-
-
0034822103
-
The effect of circuit surface area on CD11b(mac-1) expression in a rat recirculation model
-
Gourlay T, Stefanou DC, Asimakopoulos G, Taylor KM. The effect of circuit surface area on CD11b(mac-1) expression in a rat recirculation model. Artif Organs 2001; 25: 475-79.
-
(2001)
Artif. Organs.
, vol.25
, pp. 475-479
-
-
Gourlay, T.1
Stefanou, D.C.2
Asimakopoulos, G.3
Taylor, K.M.4
-
18
-
-
0036124609
-
The effect of methanol washing of plasticized polyvinyl chloride on biomaterial-contact-mediated CD11b (mac-1) expression in a rat recirculation model
-
Gourlay T, Stefanou D, Taylor KM. The effect of methanol washing of plasticized polyvinyl chloride on biomaterial-contact-mediated CD11b (mac-1) expression in a rat recirculation model. Artif Organs 2002; 26: 5-9.
-
(2002)
Artif. Organs
, vol.26
, pp. 5-9
-
-
Gourlay, T.1
Stefanou, D.2
Taylor, K.M.3
-
19
-
-
0037360327
-
Inflammatory response of rat and human neutrophils exposed to di-(2-ethyl-hexyl)-phthalate-plasticized polyvinyl chloride
-
Gourlay T, Samartzis I, Stefanou D, Taylor K. Inflammatory response of rat and human neutrophils exposed to di-(2-ethyl-hexyl)-phthalate-plasticized polyvinyl chloride. Artif Organs 2003; 27: 256-60.
-
(2003)
Artif. Organs
, vol.27
, pp. 256-260
-
-
Gourlay, T.1
Samartzis, I.2
Stefanou, D.3
Taylor, K.4
-
20
-
-
0037295361
-
Mechanisms of phthalate ester toxicity in the female reproductive system
-
Lovekamp-Swan T, Davis BJ. Mechanisms of phthalate ester toxicity in the female reproductive system. Environ Health Perspect 2003; 111: 139-45.
-
(2003)
Environ. Health Perspect.
, vol.111
, pp. 139-145
-
-
Lovekamp-Swan, T.1
Davis, B.J.2
-
21
-
-
0037414685
-
Gas chromatography-mass spectrometry determination of the migration of phthalate plasticisers from polyvinyl chloride toys and childcare articles
-
Earls AO, Axford IP, Braybrook JH. Gas chromatography-mass spectrometry determination of the migration of phthalate plasticisers from polyvinyl chloride toys and childcare articles. J Chromatogr A 2003; 983: 237-46.
-
(2003)
J. Chromatogr. A
, vol.983
, pp. 237-246
-
-
Earls, A.O.1
Axford, I.P.2
Braybrook, J.H.3
-
22
-
-
0037106105
-
FDA report identifies DEHP exposure risks
-
Traynor K. FDA report identifies DEHP exposure risks. Am J Health Syst Pharm 2002; 59: 1706-707.
-
(2002)
Am. J. Health Syst. Pharm.
, vol.59
, pp. 1706-1707
-
-
Traynor, K.1
-
23
-
-
0036651660
-
Biochemical and structural changes in RBCs stored with different plasticizers: The role of hexanol
-
Draper CJ, Greenwalt TJ, Dumaswala UJ. Biochemical and structural changes in RBCs stored with different plasticizers: the role of hexanol. Transfusion 2002; 42: 830-35.
-
(2002)
Transfusion
, vol.42
, pp. 830-835
-
-
Draper, C.J.1
Greenwalt, T.J.2
Dumaswala, U.J.3
-
24
-
-
0033251926
-
Phthalic acid is the main metabolite of the plasticizer di(2-ethylhexyl)phthalate in peritoneal dialysis patients
-
Mettang T, Alscher DM, Pauli-Magnus C, Dunst R, Kuhlmann U, Rettenmeier AW. Phthalic acid is the main metabolite of the plasticizer di(2-ethylhexyl)phthalate in peritoneal dialysis patients. Adv Perit Dial 1999; 15: 229-33.
-
(1999)
Adv. Perit. Dial.
, vol.15
, pp. 229-233
-
-
Mettang, T.1
Alscher, D.M.2
Pauli-Magnus, C.3
Dunst, R.4
Kuhlmann, U.5
Rettenmeier, A.W.6
-
25
-
-
0034830566
-
Biomaterial development for cardiopulmonary bypass
-
Gourlay T. Biomaterial development for cardiopulmonary bypass. Perfusion 2001; 16: 381-90.
-
(2001)
Perfusion
, vol.16
, pp. 381-390
-
-
Gourlay, T.1
-
26
-
-
0036803163
-
Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation
-
Fromes Y, Gaillard D, Ponzio O et al. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. Eur J Cardiothorac Surg 2002; 22: 527-33.
-
(2002)
Eur. J. Cardiothorac. Surg.
, vol.22
, pp. 527-533
-
-
Fromes, Y.1
Gaillard, D.2
Ponzio, O.3
-
27
-
-
0036223007
-
A new concept of integrated cardiopulmonary bypass circuit
-
Mueller XM, Jegger D, Augstburger M, Horisberger J, Godar G, von Segesser LK. A new concept of integrated cardiopulmonary bypass circuit. Eur J Cardiothorac Surg 2002; 21: 840-46.
-
(2002)
Eur. J. Cardiothorac. Surg.
, vol.21
, pp. 840-846
-
-
Mueller, X.M.1
Jegger, D.2
Augstburger, M.3
Horisberger, J.4
Godar, G.5
von Segesser, L.K.6
-
28
-
-
0035183320
-
MAST system: A new condensed cardiopulmonary bypass circuit for adult cardiac surgery
-
McCusker K, Vijay V, DeBois W, Helm R, Sisto D. MAST system: a new condensed cardiopulmonary bypass circuit for adult cardiac surgery. Perfusion 2001; 16: 447-52.
-
(2001)
Perfusion
, vol.16
, pp. 447-452
-
-
McCusker, K.1
Vijay, V.2
DeBois, W.3
Helm, R.4
Sisto, D.5
-
29
-
-
0037235415
-
Retrograde autologous priming: Is it useful in elective on-pump coronary artery bypass surgery?
-
Eising GP, Pfauder M, Niemeyer M et al. Retrograde autologous priming: is it useful in elective on-pump coronary artery bypass surgery? Ann Thorac Surg 2003; 75: 23-27.
-
(2003)
Ann. Thorac. Surg.
, vol.75
, pp. 23-27
-
-
Eising, G.P.1
Pfauder, M.2
Niemeyer, M.3
-
30
-
-
0036428386
-
A combined approach for improving cardiopulmonary bypass in coronary artery surgery: A pilot study
-
Baufreton C, de Brux JL, Binuani P et al. A combined approach for improving cardiopulmonary bypass in coronary artery surgery: a pilot study. Perfusion 2002; 17: 407-13.
-
(2002)
Perfusion
, vol.17
, pp. 407-413
-
-
Baufreton, C.1
de Brux, J.L.2
Binuani, P.3
-
31
-
-
0034027021
-
Size makes a difference: Use of a low-prime cardiopulmonary bypass circuit and autologous priming in small adults
-
Cormack JE, Forest RJ, Groom RC, Morton J. Size makes a difference: use of a low-prime cardiopulmonary bypass circuit and autologous priming in small adults. Perfusion 2000; 15: 129-35.
-
(2000)
Perfusion
, vol.15
, pp. 129-135
-
-
Cormack, J.E.1
Forest, R.J.2
Groom, R.C.3
Morton, J.4
-
32
-
-
0034844040
-
Glucose biosensors: 40 years of advances and challenges
-
Wang J. Glucose biosensors: 40 years of advances and challenges. Electroanalysis 2001; 13: 983-88.
-
(2001)
Electroanalysis
, vol.13
, pp. 983-988
-
-
Wang, J.1
-
33
-
-
0034158429
-
Biosensors and biochips: Advances in biological and medical diagnostics
-
Vo-Dinh T, Cullum B. Biosensors and biochips: advances in biological and medical diagnostics. Fres J Anal Chem 2000; 366: 540-51.
-
(2000)
Fres. J. Anal. Chem.
, vol.366
, pp. 540-551
-
-
Vo-Dinh, T.1
Cullum, B.2
-
34
-
-
0036313577
-
Point of care testing in the emergency department
-
Fermann GJ, Suyama J. Point of care testing in the emergency department. J Emerg Med 2002; 22: 303-404.
-
(2002)
J. Emerg. Med.
, vol.22
, pp. 303-404
-
-
Fermann, G.J.1
Suyama, J.2
-
35
-
-
0033579205
-
Non-invasive glucose monitoring: Comprehensive clinical results
-
Tamada JA, Garg S, Jovanic L, Pitzer KR, Fermi S, Potts RO. Non-invasive glucose monitoring: comprehensive clinical results. JAMA 1999; 282: 1839-44.
-
(1999)
JAMA
, vol.282
, pp. 1839-1844
-
-
Tamada, J.A.1
Garg, S.2
Jovanic, L.3
Pitzer, K.R.4
Fermi, S.5
Potts, R.O.6
-
37
-
-
84949794130
-
Opportunities at the skin interface for continuous patient monitoring
-
Proceedings of IEEE-EMBS Conference on Molecular, Cellular and Tissue Engineering, ISBN 0-7803-7557-2, Library of Congress 2002106798
-
Connolly P, Cotton C, Morin F. Opportunities at the skin interface for continuous patient monitoring. Proceedings of IEEE-EMBS Conference on Molecular, Cellular and Tissue Engineering, 2002: 57-58. ISBN 0-7803-7557-2, Library of Congress 2002106798.
-
(2002)
, pp. 57-58
-
-
Connolly, P.1
Cotton, C.2
Morin, F.3
-
38
-
-
0032897266
-
Amperometric biosensors for clinical and therapeutic drug monitoring: A review
-
Wang J. Amperometric biosensors for clinical and therapeutic drug monitoring: a review. J Pharm Biomed Anal 1999; 19: 47-53.
-
(1999)
J. Pharm. Biomed. Anal.
, vol.19
, pp. 47-53
-
-
Wang, J.1
-
39
-
-
0036883638
-
Biosensors for in vivo glucose measurement: Can we cross the experimental stage
-
Abel PU, von Woedtke T. Biosensors for in vivo glucose measurement: can we cross the experimental stage. Biosens Bioelectron 2002; 17: 1059-70
-
(2002)
Biosens Bioelectron
, vol.17
, pp. 1059-1070
-
-
Abel, P.U.1
von Woedtke, T.2
|