Volumn 38, Issue 4, 2003, Pages 714-718

The lifesite hemodialysis access system in patients with limited access

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOVENOUS FISTULA; BLOOD VESSEL GRAFT; CATHETER; CATHETER INFECTION; CLINICAL ARTICLE; CONFERENCE PAPER; CONTROLLED STUDY; DEVICE; FEMALE; GRAFT PATENCY; HEMODIALYSIS; HUMAN; MALE; PATIENT SATISFACTION; PERFORMANCE; PRIORITY JOURNAL; SURVIVAL; TREATMENT FAILURE; VASCULAR ACCESS;

EID: 0141954239     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0741-5214(03)00793-6     Document Type: Conference Paper
Times cited : (7)

References (14)
  • 2
    • 0033042819 scopus 로고    scopus 로고
    • The hemodialysis catheter conundrum: Hate living with them, but can't live without them
    • Schwab SJ, Beathard G. The hemodialysis catheter conundrum: hate living with them, but can't live without them. Kidney Int 1999;56:1-17.
    • (1999) Kidney Int , vol.56 , pp. 1-17
    • Schwab, S.J.1    Beathard, G.2
  • 3
    • 0035523812 scopus 로고    scopus 로고
    • Subcutaneous vascular access devices
    • Moran JE. Subcutaneous vascular access devices. Semin Dial 2001;14:452-7.
    • (2001) Semin Dial , vol.14 , pp. 452-457
    • Moran, J.E.1
  • 4
    • 0033744764 scopus 로고    scopus 로고
    • Initial clinical results with the LifeSite hemodialysis access system
    • Beathard GA, Posen GA. Initial clinical results with the LifeSite hemodialysis access system. Kidney Int 2000;58:2221-7.
    • (2000) Kidney Int , vol.58 , pp. 2221-2227
    • Beathard, G.A.1    Posen, G.A.2
  • 5
    • 0036842779 scopus 로고    scopus 로고
    • High performance and low complication rates of a subcutaneous vascular access device: The LifeSite hemodialysis access system
    • Lamarche MB, Zeik JC, Clark RV. High performance and low complication rates of a subcutaneous vascular access device: the LifeSite hemodialysis access system. Dial Transplant 2002;31:799-806.
    • (2002) Dial Transplant , vol.31 , pp. 799-806
    • Lamarche, M.B.1    Zeik, J.C.2    Clark, R.V.3
  • 6
    • 18744410922 scopus 로고    scopus 로고
    • Multicenter clinical trial results with the LifeSite hemodialysis access system
    • Schwab SJ, Weiss MA, Rushton F, Ross JP, Jackson J, Kapoian T, et al. Multicenter clinical trial results with the LifeSite hemodialysis access system. Kidney Int 2002;62:1026-33.
    • (2002) Kidney Int , vol.62 , pp. 1026-1033
    • Schwab, S.J.1    Weiss, M.A.2    Rushton, F.3    Ross, J.P.4    Jackson, J.5    Kapoian, T.6
  • 8
    • 85031061877 scopus 로고    scopus 로고
    • Clinical outcomes of four hemodialysis patients implanted with the LifeSite® Hemodialysis Access System: A novel approach for vascular access
    • Henry ML, editor. Chicago: W.L. Gore and Precept Press
    • Ross JR. Clinical outcomes of four hemodialysis patients implanted with the LifeSite® Hemodialysis Access System: a novel approach for vascular access. In: Henry ML, editor. Vascular access for hemodialysis-VII. Chicago: W.L. Gore and Precept Press; 2001. p. 109-121.
    • (2001) Vascular Access for Hemodialysis-VII , pp. 109-121
    • Ross, J.R.1
  • 9
    • 0035522775 scopus 로고    scopus 로고
    • Central venous dialysis catheters: Catheter-associated infection
    • Saad TF. Central venous dialysis catheters: catheter-associated infection. Semin Dial 2001;14:446-51.
    • (2001) Semin Dial , vol.14 , pp. 446-451
    • Saad, T.F.1
  • 10
    • 0033662149 scopus 로고    scopus 로고
    • Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: A prospective study
    • Oliver MJ, Callery SM, Thorpe KE, Schwab SJ, Churchill DN. Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: a prospective study. Kidney Int 2000;58:2543-5.
    • (2000) Kidney Int , vol.58 , pp. 2543-2545
    • Oliver, M.J.1    Callery, S.M.2    Thorpe, K.E.3    Schwab, S.J.4    Churchill, D.N.5
  • 12
    • 0035228229 scopus 로고    scopus 로고
    • Clinical practice guidelines for vascular access: Update 2000
    • NKF-K/DOQI. Clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 2001;37(Suppl 1):S137-81.
    • (2001) Am J Kidney Dis , vol.37 , Issue.SUPPL. 1
  • 13
    • 85031066129 scopus 로고    scopus 로고
    • Number NWE-04-02W
    • Department of Health and Human Services, US Food and Drug Administration. Warning Letter 2001. Number NWE-04-02W. Available from: URL:http://www.fda.gov/foi/warning_letters/g2045d.pdf.
    • (2001) Warning Letter 2001
  • 14
    • 0034785089 scopus 로고    scopus 로고
    • Subcutaneous implantation of the LifeSite hemodialysis access system in the femoral vein
    • Ross J. Subcutaneous implantation of the LifeSite hemodialysis access system in the femoral vein. J Vasc Access 2001;2:91-6.
    • (2001) J Vasc Access , vol.2 , pp. 91-96
    • Ross, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.