Indexed keywords
2 HYDROXYETHYL METHACRYLATE;
ETHYLENE GLYCOL DIMETHACRYLATE;
METHACRYLIC ACID DERIVATIVE;
METHACRYLIC ACID METHYL ESTER;
MONOMER;
POLYVINYLCHLORIDE;
TRIETHYLENE GLYCOL;
URETHAN DERIVATIVE;
ALCOHOL;
BISPHENOL A BIS(2 HYDROXYPROPYL) ETHER DIMETHACRYLATE;
LATEX;
MACROGOL DERIVATIVE;
NEOPRENE;
POLYMETHACRYLIC ACID DERIVATIVE;
POLYURETHAN;
RESIN;
SOLVENT;
TRIETHYLENE GLYCOL DIMETHACRYLATE;
URETHANE DIMETHACRYLATE LUTING RESIN;
ANALYSIS OF VARIANCE;
ARTICLE;
DISPOSABLE EQUIPMENT;
EXTRACTION;
GLOVE;
INTERMETHOD COMPARISON;
MATERIAL COATING;
PERMEABILITY;
ROOM TEMPERATURE;
SPECTROPHOTOMETER;
STATISTICAL SIGNIFICANCE;
CHEMISTRY;
CLASSIFICATION;
HUMAN;
MATERIALS TESTING;
NONPARAMETRIC TEST;
SURGICAL GLOVE;
TEMPERATURE;
TIME;
ULTRAVIOLET SPECTROPHOTOMETRY;
ANALYSIS OF VARIANCE;
BISPHENOL A-GLYCIDYL METHACRYLATE;
COMPOSITE RESINS;
DISPOSABLE EQUIPMENT;
ETHANOL;
GLOVES, SURGICAL;
HUMANS;
LATEX;
MATERIALS TESTING;
METHACRYLATES;
METHYLMETHACRYLATE;
NEOPRENE;
PERMEABILITY;
POLYETHYLENE GLYCOLS;
POLYMETHACRYLIC ACIDS;
POLYURETHANES;
POLYVINYL CHLORIDE;
SOLVENTS;
SPECTROPHOTOMETRY, ULTRAVIOLET;
STATISTICS, NONPARAMETRIC;
TEMPERATURE;
TIME FACTORS;
1
0018630181
Contact urticaria to rubber
Nutter A.F. Contact urticaria to rubber. Br J Dermatol. 101:1979;597-598.
(1979)
Br J Dermatol
, vol.101
, pp. 597-598
Nutter, A.F.1
2
0027723973
Reactions to latex in health care setting: Dealing with patient/worker concerns
Reactions to latex in health care setting dealing with patient/worker concerns . J Am Dent Assoc. 124:1993;91-92.
(1993)
J Am Dent Assoc
, vol.124
, pp. 91-92
3
0016771661
Contact dermatitis in surgeons from methylmethacrylate bone cement
Fries I.B., Fisher A.A., Salvati E.A. Contact dermatitis in surgeons from methylmethacrylate bone cement. J Bone Joint Surgery. 57:1975;547-549.
(1975)
J Bone Joint Surgery
, vol.57
, pp. 547-549
Fries, I.B.1
Fisher, A.A.2
Salvati, E.A.3
4
0032884572
In vivo testing of the protection of gloves against acrylates in dentin-bonding system on patients with known contact allergy to acrylates
Andersson T., Bruze M., Bjorkner B. In vivo testing of the protection of gloves against acrylates in dentin-bonding system on patients with known contact allergy to acrylates. Contact Dermatitis. 41:1999;254-259.
(1999)
Contact Dermatitis
, vol.41
, pp. 254-259
Andersson, T.1
Bruze, M.2
Bjorkner, B.3
5
0032833250
In vivo testing of the protective efficacy of gloves against allergen-containing products using an open chamber system
Andersson T., Bruze M. In vivo testing of the protective efficacy of gloves against allergen-containing products using an open chamber system. Contact Dermatitis. 41:1999;260-263.
(1999)
Contact Dermatitis
, vol.41
, pp. 260-263
Andersson, T.1
Bruze, M.2
6
0030628041
The permeability of dental gloves following exposure to certain dental materials
Tinsley D., Chadwick R.G. The permeability of dental gloves following exposure to certain dental materials. J Dent. 25:1997;65-70.
(1997)
J Dent
, vol.25
, pp. 65-70
Tinsley, D.1
Chadwick, R.G.2
7
0027669845
Permeability of latex gloves after contact with dental materials
Richards J.M., Sydiskis R.J., Davidson W.M., Josell S.D., Lavine D.S. Permeability of latex gloves after contact with dental materials. Am J Orthod Dentofacial Orthop. 104:1993;224-229.
(1993)
Am J Orthod Dentofacial Orthop
, vol.104
, pp. 224-229
Richards, J.M.1
Sydiskis, R.J.2
Davidson, W.M.3
Josell, S.D.4
Lavine, D.S.5
9
0034199483
The science of bonding: From first to sixth generation
Kugel G., Ferrari M. The science of bonding from first to sixth generation . J Am Dent Assoc. 131:(Suppl):2000;S20-25.
(2000)
J Am Dent Assoc
, vol.131
, Issue.SUPPL.
, pp. 20-25
Kugel, G.1
Ferrari, M.2
10
0033810704
Biocompatibility of resin-modified filling materials
Geurtsen W. Biocompatibility of resin-modified filling materials. Crit Rev Oral Biol Med. 11:2000;333-355.
(2000)
Crit Rev Oral Biol Med
, vol.11
, pp. 333-355
Geurtsen, W.1
11
0034909392
Allergic contact stomatitis caused by acrylic monomer in a denture
Koutis D., Freeman S. Allergic contact stomatitis caused by acrylic monomer in a denture. Australas J Dermatol. 42:2001;203-206.
(2001)
Australas J Dermatol
, vol.42
, pp. 203-206
Koutis, D.1
Freeman, S.2
12
0015230085
Contact dermatitis from penetration of rubber gloves by acrylic monomer
Pegum J.S., Medhurst F.A. Contact dermatitis from penetration of rubber gloves by acrylic monomer. Br Med J. 2:1971;141-143.
(1971)
Br Med J
, vol.2
, pp. 141-143
Pegum, J.S.1
Medhurst, F.A.2
14
84989554834
Permeability of protective gloves to (di)methacrylates in resinous dental materials
Munksgaard E.C. Permeability of protective gloves to (di)methacrylates in resinous dental materials. Scand J Dent Res. 100:1992;189-192.
(1992)
Scand J Dent Res
, vol.100
, pp. 189-192
Munksgaard, E.C.1
15
0033073795
The dental team and latex hypersensitivity
The dental team and latex hypersensitivity. J Am Dent Assoc. 130:1999;257-264.
(1999)
J Am Dent Assoc
, vol.130
, pp. 257-264