메뉴 건너뛰기




Volumn 42, Issue 4, 2003, Pages 746-751

Utility of in vitro closure time test for evaluating platelet-related primary hemostasis in dialysis patients

Author keywords

Hemostasis; In vitro closure time; Platelet aggregation; Renal insufficiency; Skin bleeding time

Indexed keywords

ADENOSINE DIPHOSPHATE; ADRENALIN; COLLAGEN;

EID: 0141732145     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0272-6386(03)00913-2     Document Type: Article
Times cited : (40)

References (26)
  • 1
    • 0024587888 scopus 로고
    • Bleeding disorders in uremia: Pathophysiology and treatment
    • Remuzzi G: Bleeding disorders in uremia: Pathophysiology and treatment. Adv Nephrol 18:171-186, 1989
    • (1989) Adv Nephrol , vol.18 , pp. 171-186
    • Remuzzi, G.1
  • 2
    • 0028348766 scopus 로고
    • Hemostasis in renal disease: Pathophysiology and management
    • Eberst ME, Berkowitz LR: Hemostasis in renal disease: Pathophysiology and management. Am J Med 96:168-179, 1994
    • (1994) Am J Med , vol.96 , pp. 168-179
    • Eberst, M.E.1    Berkowitz, L.R.2
  • 4
    • 0022611325 scopus 로고
    • Uraemic platelets
    • Rao AK: Uraemic platelets. Lancet 1:913-914, 1986
    • (1986) Lancet , vol.1 , pp. 913-914
    • Rao, A.K.1
  • 5
    • 0031873310 scopus 로고    scopus 로고
    • Uremic bleeding: Pathogenesis and therapy
    • Weigert AL, Schafer AI: Uremic bleeding: Pathogenesis and therapy. Am J Med Sci 316:94-104, 1998
    • (1998) Am J Med Sci , vol.316 , pp. 94-104
    • Weigert, A.L.1    Schafer, A.I.2
  • 6
    • 10344238129 scopus 로고    scopus 로고
    • Hemostatic disorder of uremia: The platelet defect, main determinant of prolonged bleeding time, is correlated with indices of activation of coagulation and fibrinolysis
    • Mezzano D, Tagle R, Panes O, et al: Hemostatic disorder of uremia: The platelet defect, main determinant of prolonged bleeding time, is correlated with indices of activation of coagulation and fibrinolysis. Thromb Haemost 76:312-321, 1996
    • (1996) Thromb Haemost , vol.76 , pp. 312-321
    • Mezzano, D.1    Tagle, R.2    Panes, O.3
  • 7
    • 0032857219 scopus 로고    scopus 로고
    • Uremic bleeding: Closing the circle after 30 years of controversies?
    • Noris M, Remuzzi G: Uremic bleeding: Closing the circle after 30 years of controversies? Blood 94:2569-2574, 1999
    • (1999) Blood , vol.94 , pp. 2569-2574
    • Noris, M.1    Remuzzi, G.2
  • 8
    • 0023886940 scopus 로고
    • Bleeding in renal failure
    • Remuzzi G: Bleeding in renal failure. Lancet 1:1205-1208, 1988
    • (1988) Lancet , vol.1 , pp. 1205-1208
    • Remuzzi, G.1
  • 10
    • 0018581123 scopus 로고
    • Bleeding time in uremia: A useful test to assess clinical bleeding
    • Steiner RW, Coggins C, Carvalho AC: Bleeding time in uremia: a useful test to assess clinical bleeding. Am J Hematol 7:107-117, 1979
    • (1979) Am J Hematol , vol.7 , pp. 107-117
    • Steiner, R.W.1    Coggins, C.2    Carvalho, A.C.3
  • 11
    • 0036169990 scopus 로고    scopus 로고
    • The laboratory diagnosis of platelet disorders. An algorithmic approach
    • Marchant KK, Corcoran G: The laboratory diagnosis of platelet disorders. An algorithmic approach. Arch Pathol Lab Med 126:133-146, 2002
    • (2002) Arch Pathol Lab Med , vol.126 , pp. 133-146
    • Marchant, K.K.1    Corcoran, G.2
  • 12
    • 0033377551 scopus 로고    scopus 로고
    • Is the bleeding time predictive of bleeding prior to a percutaneous renal biopsy?
    • Mattix H, Singh AK: Is the bleeding time predictive of bleeding prior to a percutaneous renal biopsy? Curr Opin Nephrol Hypertens 8:715-718, 1999
    • (1999) Curr Opin Nephrol Hypertens , vol.8 , pp. 715-718
    • Mattix, H.1    Singh, A.K.2
  • 13
    • 0034955354 scopus 로고    scopus 로고
    • Discontinuation of the bleeding time test without detectable adverse clinical impact
    • Lehman CM, Blaylock RC, Alexander DP, Rodgers GM: Discontinuation of the bleeding time test without detectable adverse clinical impact. Clin Chem 47:1204-1211, 2001
    • (2001) Clin Chem , vol.47 , pp. 1204-1211
    • Lehman, C.M.1    Blaylock, R.C.2    Alexander, D.P.3    Rodgers, G.M.4
  • 14
    • 0008649975 scopus 로고
    • Platelet function defects: Simulation of primary hemostasis in vitro
    • Kratzer MAA, Born GVR: Platelet function defects: Simulation of primary hemostasis in vitro. Hemostasis 18: 167-185, 1985
    • (1985) Hemostasis , vol.18 , pp. 167-185
    • Kratzer, M.A.A.1    Born, G.V.R.2
  • 16
    • 0031596559 scopus 로고    scopus 로고
    • PFA-100™ System: A new method for assessment of platelet dysfunction
    • Mammen EF, Comp PC, Gosselin R, et al: PFA-100™ System: A new method for assessment of platelet dysfunction. Semin Thromb Hemostasis 24:195-202, 1998
    • (1998) Semin Thromb Hemostasis , vol.24 , pp. 195-202
    • Mammen, E.F.1    Comp, P.C.2    Gosselin, R.3
  • 17
    • 0035080832 scopus 로고    scopus 로고
    • Utility of the PFA-100 for assessing bleeding disorders and monitoring therapy: A review of analytical variables, benefits and limitations
    • Favaloro EJ: Utility of the PFA-100 for assessing bleeding disorders and monitoring therapy: A review of analytical variables, benefits and limitations. Haemophilia 7:170-179, 2001
    • (2001) Haemophilia , vol.7 , pp. 170-179
    • Favaloro, E.J.1
  • 18
    • 0030851305 scopus 로고    scopus 로고
    • A comparison of the effects of aspirin on bleeding time measured using the Simplate™ method and closure time measured using the PFA-100™, in healthy volunteers
    • Marshall PW, Williams AJ, Dixon RM, et al: A comparison of the effects of aspirin on bleeding time measured using the Simplate™ method and closure time measured using the PFA-100™, in healthy volunteers. Br J Clin Pharmacol 44:151-155, 1997
    • (1997) Br J Clin Pharmacol , vol.44 , pp. 151-155
    • Marshall, P.W.1    Williams, A.J.2    Dixon, R.M.3
  • 19
    • 0034742126 scopus 로고    scopus 로고
    • The PFA-100 system for the assessment of platelet function in normotensive and hypertensive pregnancies
    • Marietta M, Castelli I, Piccinini F, et al: The PFA-100 system for the assessment of platelet function in normotensive and hypertensive pregnancies. Clin Lab Haematol 23: 131-134, 2001
    • (2001) Clin Lab Haematol , vol.23 , pp. 131-134
    • Marietta, M.1    Castelli, I.2    Piccinini, F.3
  • 20
    • 0035868302 scopus 로고    scopus 로고
    • Clinical utility of the platelet function analyzer (PFA-100) for the assessment of the platelet status in patients with congestive heart failure (EPCOT trial)
    • Serebruany VL, Alford A, Meister AF, et al: Clinical utility of the platelet function analyzer (PFA-100) for the assessment of the platelet status in patients with congestive heart failure (EPCOT trial). Thromb Res 15:427-433, 2001
    • (2001) Thromb Res , vol.15 , pp. 427-433
    • Serebruany, V.L.1    Alford, A.2    Meister, A.F.3
  • 21
    • 0012815726 scopus 로고    scopus 로고
    • Investigation of hemostasis
    • Lewis SM (ed). New York, NY, Churchill Livingstone
    • Laffan MA, Manning RA: Investigation of hemostasis, in Lewis SM (ed): Practical Haematology (ed 9). New York, NY, Churchill Livingstone, 2001, pp 339-390
    • (2001) Practical Haematology (Ed 9) , pp. 339-390
    • Laffan, M.A.1    Manning, R.A.2
  • 22
    • 0346367328 scopus 로고
    • Aggregation of blood platelets by adenosine diphosphate and its reversal
    • Born GVR: Aggregation of blood platelets by adenosine diphosphate and its reversal. Nature 194:927-929, 1962
    • (1962) Nature , vol.194 , pp. 927-929
    • Born, G.V.R.1
  • 23
    • 0040668664 scopus 로고    scopus 로고
    • Laboratory evaluation of hemostatic disorders
    • Hoffman R (ed). New York, NY, Churchill Livingstone
    • Santoro SA, Eby CS: Laboratory evaluation of hemostatic disorders, in Hoffman R (ed): Hematology: Basic Principles and Practise (ed 3). New York, NY, Churchill Livingstone, 2000, pp 1841-1850
    • (2000) Hematology: Basic Principles and Practise (Ed 3) , pp. 1841-1850
    • Santoro, S.A.1    Eby, C.S.2
  • 24
    • 0036344893 scopus 로고    scopus 로고
    • Clinical application of the PFA-100
    • Favaloro EJ: Clinical application of the PFA-100. Curr Opin Hematol 9:407-415, 2002
    • (2002) Curr Opin Hematol , vol.9 , pp. 407-415
    • Favaloro, E.J.1
  • 25
    • 0032766096 scopus 로고    scopus 로고
    • Evaluation of acquired platelet dysfunctions in uremic and cirrotic patients using the platelet function analyser (PFA-100™): Influence of hematocrit elevation
    • Escolar G, Cases A, Vinas M, et al: Evaluation of acquired platelet dysfunctions in uremic and cirrotic patients using the platelet function analyser (PFA-100™): Influence of hematocrit elevation. Haematologica 84:614-619, 1999
    • (1999) Haematologica , vol.84 , pp. 614-619
    • Escolar, G.1    Cases, A.2    Vinas, M.3
  • 26
    • 0036474295 scopus 로고    scopus 로고
    • Comparison of in vitro closure time (PFA-100) with whole blood electrical aggregometry and platelet surface antigen expression in healthy volunteers
    • Salat A, Kroess S, Felfernig-Boehm D, et al: Comparison of in vitro closure time (PFA-100) with whole blood electrical aggregometry and platelet surface antigen expression in healthy volunteers. Thromb Res 105:205-208, 2002
    • (2002) Thromb Res , vol.105 , pp. 205-208
    • Salat, A.1    Kroess, S.2    Felfernig-Boehm, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.