메뉴 건너뛰기




Volumn 5, Issue , 2003, Pages 1-4

Image combination for high-field phased-array MRI

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; FOURIER TRANSFORMS; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE IMAGING; VECTORS;

EID: 0141632709     PISSN: 15206149     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0031425055 scopus 로고    scopus 로고
    • Theory and application of array coils in MR spectroscopy
    • S. M. Wright and L. L. Wald, "Theory and application of array coils in MR spectroscopy," NMR in Biomedicine, vol. 10, pp. 394-410, 1997.
    • (1997) NMR in Biomedicine , vol.10 , pp. 394-410
    • Wright, S.M.1    Wald, L.L.2
  • 5
    • 0030669303 scopus 로고    scopus 로고
    • Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements
    • J. P. Debbins, J. P. Felmlee, and S. J. Riederer, "Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements," Magnetic Resonance in Medicine, vol. 38, pp. 1003-1011, 1997.
    • (1997) Magnetic Resonance in Medicine , vol.38 , pp. 1003-1011
    • Debbins, J.P.1    Felmlee, J.P.2    Riederer, S.J.3
  • 6
    • 0036187917 scopus 로고    scopus 로고
    • Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    • M. Bydder, D. J. Larkman, and J. V. Hajnal, "Combination of signals from array coils using image-based estimation of coil sensitivity profiles," Magnetic Resonance in Medicine, vol. 47, pp. 539-548, 2002.
    • (2002) Magnetic Resonance in Medicine , vol.47 , pp. 539-548
    • Bydder, M.1    Larkman, D.J.2    Hajnal, J.V.3
  • 7
    • 0034899816 scopus 로고    scopus 로고
    • Ghost artifact cancellation using phased array processing
    • P. Kellman and E. R. McVeigh, "Ghost artifact cancellation using phased array processing," Magnetic Resonance in Medicine, vol. 46, pp. 335-343, 2001.
    • (2001) Magnetic Resonance in Medicine , vol.46 , pp. 335-343
    • Kellman, P.1    McVeigh, E.R.2
  • 11
    • 0035504506 scopus 로고    scopus 로고
    • Phased array imaging on a 4.7T/33cm animal research system
    • B. L. Beck and S. J. Blackband, "Phased array imaging on a 4.7T/ 33cm animal research system," Review of Scientific Instruments, vol. 72, no. 11, pp. 4292-4294, 2001.
    • (2001) Review of Scientific Instruments , vol.72 , Issue.11 , pp. 4292-4294
    • Beck, B.L.1    Blackband, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.