메뉴 건너뛰기




Volumn 2, Issue 3, 2003, Pages 164-171

Image fusion of CT and MRI data enables improved target volume definition in 3D-brachytherapy treatment planning

Author keywords

Brachytherapy; Image fusion; Treatment planning

Indexed keywords

ARTICLE; BRACHYTHERAPY; CANCER RECURRENCE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; FEASIBILITY STUDY; HEAD AND NECK CANCER; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMPLANTATION; LIPOSARCOMA; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RELIABILITY; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING; UTERINE CERVIX CANCER; VULVA CANCER;

EID: 0141449136     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1538-4721(03)00133-8     Document Type: Article
Times cited : (70)

References (33)
  • 1
    • 0036535419 scopus 로고    scopus 로고
    • Brachytherapy for T1-T2 floor-of-the-mouth cancers: The Gustave-Roussy Institute experience
    • Marsiglia H., Haie-Meder C., Sasso G., et al. Brachytherapy for T1-T2 floor-of-the-mouth cancers: The Gustave-Roussy Institute experience. Int J Radiat Oncol Biol Phys. 52:2002;1257-1263.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1257-1263
    • Marsiglia, H.1    Haie-Meder, C.2    Sasso, G.3
  • 2
    • 0141454111 scopus 로고    scopus 로고
    • Cesium-137 needle brachytherapy boosts after external beam irradiation for locally advanced carcinoma of the tongue and floor of the mouth
    • Leborgne F., Leborgne J.H., Zubizarreta E., et al. Cesium-137 needle brachytherapy boosts after external beam irradiation for locally advanced carcinoma of the tongue and floor of the mouth. Brachytherapy. 1:2002;126-130.
    • (2002) Brachytherapy , vol.1 , pp. 126-130
    • Leborgne, F.1    Leborgne, J.H.2    Zubizarreta, E.3
  • 3
    • 0141565655 scopus 로고    scopus 로고
    • Pulsed-dose rate brachytherapy with concomitant chemotherapy and interstitial hyperthermia in patients with recurrent head and neck cancer
    • Geiger M., Strnad V., Lotter M., et al. Pulsed-dose rate brachytherapy with concomitant chemotherapy and interstitial hyperthermia in patients with recurrent head and neck cancer. Brachytherapy. 1:2002;149-153.
    • (2002) Brachytherapy , vol.1 , pp. 149-153
    • Geiger, M.1    Strnad, V.2    Lotter, M.3
  • 5
    • 0036854232 scopus 로고    scopus 로고
    • Five-year results of pulsed-dose-rate Brachytherapy applied as a boost after breast-conserving therapy in patients at high risk for local recurrence from breast cancer
    • Harms W., Krempien R., Hensley F.W., et al. Five-year results of pulsed-dose-rate Brachytherapy applied as a boost after breast-conserving therapy in patients at high risk for local recurrence from breast cancer. Strahlenther Onkol. 178:2002;607-614.
    • (2002) Strahlenther Onkol , vol.178 , pp. 607-614
    • Harms, W.1    Krempien, R.2    Hensley, F.W.3
  • 6
    • 0036781496 scopus 로고    scopus 로고
    • Localized prostate cancer: Brachytherapy
    • Zietman A.L. Localized prostate cancer: Brachytherapy. Curr Treat Options Oncol. 3:2002;429-436.
    • (2002) Curr Treat Options Oncol , vol.3 , pp. 429-436
    • Zietman, A.L.1
  • 7
    • 0033860233 scopus 로고    scopus 로고
    • Matched-pair analysis of conformal high-dose-rate brachytherapy boost versus external-beam radiation therapy alone for locally advanced prostate cancer
    • Kestin L.L., Martinez A.A., Stromberg J.S., et al. Matched-pair analysis of conformal high-dose-rate brachytherapy boost versus external-beam radiation therapy alone for locally advanced prostate cancer. J Clin Oncol. 18:2000;2869-2880.
    • (2000) J Clin Oncol , vol.18 , pp. 2869-2880
    • Kestin, L.L.1    Martinez, A.A.2    Stromberg, J.S.3
  • 8
    • 0036471508 scopus 로고    scopus 로고
    • A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model
    • Hsu I.C., Speight J., Hai J., et al. A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model. Int J Radiat Oncol Biol Phys. 52:2002;538-543.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 538-543
    • Hsu, I.C.1    Speight, J.2    Hai, J.3
  • 10
    • 0030866232 scopus 로고    scopus 로고
    • CT-based dosimetry for transperineal I-125 prostate brachytherapy
    • Willins J., Wallner K. CT-based dosimetry for transperineal I-125 prostate brachytherapy. Int J Radiat Oncol Biol Phys. 39:1997;347-353.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 347-353
    • Willins, J.1    Wallner, K.2
  • 11
    • 0031055222 scopus 로고    scopus 로고
    • Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning
    • Khoo V.S., Dearnaley D.P., Finnigan D.J., et al. Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning. Radiother Oncol. 42:1997;1-15.
    • (1997) Radiother Oncol , vol.42 , pp. 1-15
    • Khoo, V.S.1    Dearnaley, D.P.2    Finnigan, D.J.3
  • 12
    • 0002585715 scopus 로고    scopus 로고
    • Artifacts in MRI: Description, causes, and solutions
    • R.R. Edelmann, J.K. Hesselink, & M.B. Zlatkin. Philadelphia: Saunders
    • Wesby G., Adamis M.K., Edelmann R.R. Artifacts in MRI: description, causes, and solutions. Edelmann R.R., Hesselink J.K., Zlatkin M.B. Clinical magnetic resonance imaging. 1996;88-144 Saunders, Philadelphia.
    • (1996) Clinical magnetic resonance imaging , pp. 88-144
    • Wesby, G.1    Adamis, M.K.2    Edelmann, R.R.3
  • 13
    • 0028289056 scopus 로고
    • Accurate frameless registration of MR and CT images of the head: Applications in planning surgery and radiation therapy
    • Hill D.L.G., Hawkes D.J., Gleeson M.J., et al. Accurate frameless registration of MR and CT images of the head: Applications in planning surgery and radiation therapy. Radiology. 191:1994;447-454.
    • (1994) Radiology , vol.191 , pp. 447-454
    • Hill, D.L.G.1    Hawkes, D.J.2    Gleeson, M.J.3
  • 14
    • 0031663432 scopus 로고    scopus 로고
    • Image processing in stereotactic planning: Volume visualization and image registration
    • Pelizzari C.A. Image processing in stereotactic planning: Volume visualization and image registration. Medical Dosimetry. 23:1998;137-145.
    • (1998) Medical Dosimetry , vol.23 , pp. 137-145
    • Pelizzari, C.A.1
  • 16
    • 0032587369 scopus 로고    scopus 로고
    • Possibilities of an open magnetic resonance scanner integration in therapy simulation and three-dimensional radiotherapy planning
    • Schubert K., Wenz F., Krempien R., et al. Possibilities of an open magnetic resonance scanner integration in therapy simulation and three-dimensional radiotherapy planning. Strahlenther Onkol. 175:1999;225-231.
    • (1999) Strahlenther Onkol , vol.175 , pp. 225-231
    • Schubert, K.1    Wenz, F.2    Krempien, R.3
  • 17
    • 0036680342 scopus 로고    scopus 로고
    • Open low field magnetic resonance imaging (MRI) in radiation therapy treatment planning
    • Krempien R.C., Schubert K., Zierhut D., et al. Open low field magnetic resonance imaging (MRI) in radiation therapy treatment planning. Int J Radiat Oncol Biol Phys. 53:2002;1350-1360.
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1350-1360
    • Krempien, R.C.1    Schubert, K.2    Zierhut, D.3
  • 18
    • 0032871479 scopus 로고    scopus 로고
    • Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynecological cancer
    • Buchali A., Koswig S., Dinges S., et al. Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynecological cancer. Radiother Oncol. 52:1999;29-34.
    • (1999) Radiother Oncol , vol.52 , pp. 29-34
    • Buchali, A.1    Koswig, S.2    Dinges, S.3
  • 20
    • 0034092127 scopus 로고    scopus 로고
    • Ligating clips for three-dimensional MR angiography at 1.5T: In vitro evaluation
    • Weishaupt D., Quick H.H., Nanz D., et al. Ligating clips for three-dimensional MR angiography at 1.5T: In vitro evaluation. Radiology. 214:2000;902-907.
    • (2000) Radiology , vol.214 , pp. 902-907
    • Weishaupt, D.1    Quick, H.H.2    Nanz, D.3
  • 21
    • 0035425537 scopus 로고    scopus 로고
    • The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for head-and-neck carcinoma
    • Nag S., Cano E.R., Demanes D.J., et al. The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for head-and-neck carcinoma. Int J Radiat Oncol Biol Phys. 50:2001;1190-1198.
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1190-1198
    • Nag, S.1    Cano, E.R.2    Demanes, D.J.3
  • 22
    • 0025299691 scopus 로고
    • Peripheral nerve and ureteral tolerance to intraoperative radiation therapy: Clinical and dose-response analysis
    • Shaw E.G., Gunderson L.L., Martin J.K., et al. Peripheral nerve and ureteral tolerance to intraoperative radiation therapy: Clinical and dose-response analysis. Radiother Oncol. 18:1990;247-255.
    • (1990) Radiother Oncol , vol.18 , pp. 247-255
    • Shaw, E.G.1    Gunderson, L.L.2    Martin, J.K.3
  • 23
    • 0028984177 scopus 로고
    • Clinical toxicity of peripheral nerve to intraoperative radiotherapy in a canine model
    • Johnstone P.A.S., DeLuca A.M., Bacher J.D., et al. Clinical toxicity of peripheral nerve to intraoperative radiotherapy in a canine model. Int J Radiat Oncol Biol Phys. 32:1995;1031-1034.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 1031-1034
    • Johnstone, P.A.S.1    DeLuca, A.M.2    Bacher, J.D.3
  • 24
    • 0030175512 scopus 로고    scopus 로고
    • Dose-volume histogram analysis of high-dose-rate intracavitary brachytherapy for uterine cervix cancer
    • Terahara A., Nakano T., Ishikawa A., et al. Dose-volume histogram analysis of high-dose-rate intracavitary brachytherapy for uterine cervix cancer. Int J Radiat Oncol Biol Phys. 35:1996;549-554.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 549-554
    • Terahara, A.1    Nakano, T.2    Ishikawa, A.3
  • 25
    • 84940130997 scopus 로고
    • Transposition of target information from magnetic resonance and computed tomography scan images to conventional stereotactic space
    • De Salles A.W.T., Abe M., Kjellberg R.N. Transposition of target information from magnetic resonance and computed tomography scan images to conventional stereotactic space. Appl Neurophysiol. 50:1987;23-32.
    • (1987) Appl Neurophysiol , vol.50 , pp. 23-32
    • De Salles, A.W.T.1    Abe, M.2    Kjellberg, R.N.3
  • 27
    • 0031230541 scopus 로고    scopus 로고
    • The registration of multiple images acquired from a single subject: Why, how, what next?
    • Little J.A., Hawkes D.J. The registration of multiple images acquired from a single subject: Why, how, what next? Statistical Methods in Medical Research. 6:1997;239-265.
    • (1997) Statistical Methods in Medical Research , vol.6 , pp. 239-265
    • Little, J.A.1    Hawkes, D.J.2
  • 28
    • 0031727317 scopus 로고    scopus 로고
    • Algorithms for radiological image registration and their clinical application
    • Hawkes D.J. Algorithms for radiological image registration and their clinical application. J Anat. 193:1998;347-361.
    • (1998) J Anat , vol.193 , pp. 347-361
    • Hawkes, D.J.1
  • 29
    • 0032934241 scopus 로고    scopus 로고
    • Prostate seed implant quality assessment using MR and CT image fusion
    • Amdur R.J., Gladstone D., Leopold K.A., et al. Prostate seed implant quality assessment using MR and CT image fusion. Int J Radiat Oncol Biol Phys. 43:1999;67-72.
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 67-72
    • Amdur, R.J.1    Gladstone, D.2    Leopold, K.A.3
  • 30
    • 0035188625 scopus 로고    scopus 로고
    • CT and MRI derived source localization error in a custom prostate phantom using automated image coregistration
    • Dubois D.F., Bice W.S. Jr., Prestige B.R. CT and MRI derived source localization error in a custom prostate phantom using automated image coregistration. Med Phys. 28:2001;2280-2284.
    • (2001) Med Phys , vol.28 , pp. 2280-2284
    • Dubois, D.F.1    Bice W.S., Jr.2    Prestige, B.R.3
  • 31
    • 0034548067 scopus 로고    scopus 로고
    • The application of image fusion in stereotactic brachytherapy of brain tumours
    • Julow J., Major T., Emri M., et al. The application of image fusion in stereotactic brachytherapy of brain tumours. Acta Neurochir. 142:2000;1253-1258.
    • (2000) Acta Neurochir , vol.142 , pp. 1253-1258
    • Julow, J.1    Major, T.2    Emri, M.3
  • 32
    • 0031724260 scopus 로고    scopus 로고
    • Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer
    • D'Amico A.V., Cormack R., Tempany C.M., et al. Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer. Int J Radiat Oncol Biol Phys. 42:1998;507-515.
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 507-515
    • D'Amico, A.V.1    Cormack, R.2    Tempany, C.M.3
  • 33
    • 0034212270 scopus 로고    scopus 로고
    • Open magnetic resonance imaging using titanium-zirconium needles: Improved accuracy for interstitial brachytherapy implants?
    • Popowski Y., Hiltbrand E., Joliat D., et al. Open magnetic resonance imaging using titanium-zirconium needles: Improved accuracy for interstitial brachytherapy implants? Int J Radiat Oncol Biol Phys. 47:2000;759-765.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 759-765
    • Popowski, Y.1    Hiltbrand, E.2    Joliat, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.