메뉴 건너뛰기




Volumn 23, Issue 4, 2003, Pages 361-369

Linear birefringence measurements of the in vitro human cornea

Author keywords

Azimuth angle; Birefringence; Cornea; Polarimetry; Retardation

Indexed keywords

ANISOTROPY; ARTICLE; BIREFRINGENCE; COMPUTER SYSTEM; CORNEA; EYEBANK; IN VITRO STUDY; POLARIMETRY; PRIORITY JOURNAL; HUMAN; INSTRUMENTATION; LASER; OPTICS; PHYSIOLOGY;

EID: 0141448766     PISSN: 02755408     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1475-1313.2003.00128.x     Document Type: Article
Times cited : (23)

References (24)
  • 1
    • 0017326865 scopus 로고
    • An interpretation of small-angle light-scattering patterns of human cornea
    • Bettelheim, F. A. and Mahadeva, K. (1977) An interpretation of small-angle light-scattering patterns of human cornea. Invest. Ophthalmol. Visual Sci. 16, 233-236.
    • (1977) Invest. Ophthalmol. Visual Sci. , vol.16 , pp. 233-236
    • Bettelheim, F.A.1    Mahadeva, K.2
  • 3
    • 0002720455 scopus 로고
    • Polarized light and the eye
    • ed W. N. Charman , CRC Press Inc, Macmillan, New York
    • Bour, L. J. (1991) Polarized light and the eye. In: Visual Optics and Instrumentation (ed W. N. Charman ), CRC Press Inc, Macmillan, New York. pp. 310-325.
    • (1991) Visual Optics and Instrumentation , pp. 310-325
    • Bour, L.J.1
  • 4
    • 0019407866 scopus 로고
    • On the birefringence of the living human eye
    • Bour, L. J. and Cardozo, N. J. L. (1981) On the birefringence of the living human eye. Vision Res. 21, 1413-1421.
    • (1981) Vision Res. , vol.21 , pp. 1413-1421
    • Bour, L.J.1    Cardozo, N.J.L.2
  • 5
    • 0002810045 scopus 로고    scopus 로고
    • Double-pass imaging polarimetry in the human eye
    • Bueno, J. M. and Artal, P. (1999) Double-pass imaging polarimetry in the human eye. Opt. Lett. 24, 64-66.
    • (1999) Opt. Lett. , vol.24 , pp. 64-66
    • Bueno, J.M.1    Artal, P.2
  • 6
    • 0034911959 scopus 로고    scopus 로고
    • Spatially resolved polarization properties for in vitro corneas
    • Bueno, J. M. and Jaronski, J. W. (2001) Spatially resolved polarization properties for in vitro corneas. Ophthal. Physiol. Opt. 21, 384-392.
    • (2001) Ophthal. Physiol. Opt. , vol.21 , pp. 384-392
    • Bueno, J.M.1    Jaronski, J.W.2
  • 7
    • 0036017336 scopus 로고    scopus 로고
    • Measurements of the corneal birefringence with a liquid-crystal imaging polariscope
    • Bueno, J. M. and Vargas-Martin, F. (2002) Measurements of the corneal birefringence with a liquid-crystal imaging polariscope. Appl. Opt. 41, 116-124.
    • (2002) Appl. Opt. , vol.41 , pp. 116-124
    • Bueno, J.M.1    Vargas-Martin, F.2
  • 8
    • 0031024768 scopus 로고    scopus 로고
    • Collagen fibril orientation in the human corneal stroma and its implications in Keratoconus
    • Daxer, A. and Fratzl, P. (1997) Collagen fibril orientation in the human corneal stroma and its implications in Keratoconus. Invest. Ophthalmol. Visual Sci. 38, 121-129.
    • (1997) Invest. Ophthalmol. Visual Sci. , vol.38 , pp. 121-129
    • Daxer, A.1    Fratzl, P.2
  • 9
    • 0029339562 scopus 로고
    • Numerical modeling of the cornea's lamellar structure and birefringence properties
    • Donohue, D. J., Stoyanow, B. J., McCally, R. L. and Farrell, R.A. (1995) Numerical modeling of the cornea's lamellar structure and birefringence properties. J. Opt. Soc. Am. A 12, 1425-1438.
    • (1995) J. Opt. Soc. Am. A , vol.12 , pp. 1425-1438
    • Donohue, D.J.1    Stoyanow, B.J.2    McCally, R.L.3    Farrell, R.A.4
  • 12
    • 0033858678 scopus 로고    scopus 로고
    • Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry
    • Greenfield, D. S., Knighton, R. W. and Huang, X. R. (2000) Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am. J. Ophthalmol. 129, 715-722.
    • (2000) Am. J. Ophthalmol. , vol.129 , pp. 715-722
    • Greenfield, D.S.1    Knighton, R.W.2    Huang, X.R.3
  • 13
    • 0001129908 scopus 로고    scopus 로고
    • Generalized algorithm for photoelastic measurements based on phase-stepping imaging polarimetry
    • Jaronski, J. W. and Kasprzak, H. T. (1999) Generalized algorithm for photoelastic measurements based on phase-stepping imaging polarimetry. Appl. Opt. 38, 7018-7025.
    • (1999) Appl. Opt. , vol.38 , pp. 7018-7025
    • Jaronski, J.W.1    Kasprzak, H.T.2
  • 15
    • 0036139716 scopus 로고    scopus 로고
    • Linear birefringence measured in the central human cornea
    • Knighton, R. W. and Huang, X. R. (2002) Linear birefringence measured in the central human cornea. Invest. Ophthalmol. Visual Sci. 43, 82-86.
    • (2002) Invest. Ophthalmol. Visual Sci. , vol.43 , pp. 82-86
    • Knighton, R.W.1    Huang, X.R.2
  • 17
    • 0020060942 scopus 로고
    • Structural implications of small-angle light scattering from cornea
    • McCally, R. L. and Farrell, R. A. (1982) Structural implications of small-angle light scattering from cornea. Exp. Eye Res. 34, 99-113.
    • (1982) Exp. Eye Res. , vol.34 , pp. 99-113
    • McCally, R.L.1    Farrell, R.A.2
  • 18
    • 0002567294 scopus 로고
    • The cornea and sciera
    • ed. H. Davson , Academic, Orlando, FL
    • Maurice, D. M. (1984) The cornea and sciera. In: The Eye (ed. H. Davson ), Academic, Orlando, FL, pp. 1-158.
    • (1984) The Eye , pp. 1-158
    • Maurice, D.M.1
  • 19
    • 0004458774 scopus 로고
    • Polarized light studies of the corneal structure
    • Naylor, E. J. (1953) Polarized light studies of the corneal structure. Br. J. Ophthal. 37, 77-84.
    • (1953) Br. J. Ophthal. , vol.37 , pp. 77-84
    • Naylor, E.J.1
  • 20
    • 0031722984 scopus 로고    scopus 로고
    • The integration of the corneal and limbal fibrils in the human eye
    • Newton, R. H. and Meek K. M. (1998) The integration of the corneal and limbal fibrils in the human eye. Biophys. J. 75, 2508-2512.
    • (1998) Biophys. J. , vol.75 , pp. 2508-2512
    • Newton, R.H.1    Meek, K.M.2
  • 21
    • 0031717072 scopus 로고    scopus 로고
    • Interlacing and cross-angle distribution of collagen lamellae in the human cornea
    • Radner, W., Zehetmayer, M. and Aufreiter, R. (1998) Interlacing and cross-angle distribution of collagen lamellae in the human cornea. Cornea 17, 537-543.
    • (1998) Cornea , vol.17 , pp. 537-543
    • Radner, W.1    Zehetmayer, M.2    Aufreiter, R.3
  • 22
    • 0000156217 scopus 로고
    • The polarization optics of the isolated cornea
    • Stanworth, A. and Naylor, E. J. (1950) The polarization optics of the isolated cornea. Br. J. Ophthal. 34, 201-211.
    • (1950) Br. J. Ophthal. , vol.34 , pp. 201-211
    • Stanworth, A.1    Naylor, E.J.2
  • 23
    • 0023070873 scopus 로고
    • Corneal polarization in the living human eye explained with a biaxial model
    • Van Blokland, G. J. and Verhelst, S. C. (1987) Corneal polarization in the living human eye explained with a biaxial model. J. Opt. Soc. Am. A 4, 82-90.
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 82-90
    • Van Blokland, G.J.1    Verhelst, S.C.2
  • 24
    • 0036293309 scopus 로고    scopus 로고
    • Individualized compensation of anterior segment birefringence during scanning laser polarimetry
    • Zhou, Q. and Weinreb, R. N. (2002) Individualized compensation of anterior segment birefringence during scanning laser polarimetry. Invest. Ophthalmol. Visual Sci. 43, 2221-2228.
    • (2002) Invest. Ophthalmol. Visual Sci. , vol.43 , pp. 2221-2228
    • Zhou, Q.1    Weinreb, R.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.