메뉴 건너뛰기




Volumn 4, Issue 1, 2002, Pages 41-44

Delayed recognition of esophageal intubation

Author keywords

Esophageal; Intubation; Mortality

Indexed keywords


EID: 0043144506     PISSN: 14818035     EISSN: 14818035     Source Type: Journal    
DOI: 10.1017/S1481803500006047     Document Type: Article
Times cited : (11)

References (23)
  • 1
    • 0031043722 scopus 로고    scopus 로고
    • Visualization of the extrahepatic segment of the ligamentum teres: A sign of free air on plain radiographs
    • Cho KC. Visualization of the extrahepatic segment of the ligamentum teres: a sign of free air on plain radiographs. Radiology 1997;202:651-4.
    • (1997) Radiology , vol.202 , pp. 651-654
    • Cho, K.C.1
  • 2
    • 0031896381 scopus 로고    scopus 로고
    • Airway management in the emergency department: A one-year study of 610 tracheal intubations
    • Sakles JC, Laurin EG, Rantapaa AA, Panacek E. Airway management in the emergency department: A one-year study of 610 tracheal intubations. Ann Emerg Med 1998;31:325-32.
    • (1998) Ann Emerg Med , vol.31 , pp. 325-332
    • Sakles, J.C.1    Laurin, E.G.2    Rantapaa, A.A.3    Panacek, E.4
  • 3
    • 0028868095 scopus 로고
    • Death and other implications of emergency airway management in critically ill adults: A prospective investigation of 297 tracheal intubations
    • Schwartz DE, Mattay MA, Cohen NH. Death and other implications of emergency airway management in critically ill adults: a prospective investigation of 297 tracheal intubations. Anaesthesiology 1995;82:367-76.
    • (1995) Anaesthesiology , vol.82 , pp. 367-376
    • Schwartz, D.E.1    Mattay, M.A.2    Cohen, N.H.3
  • 4
    • 4243646907 scopus 로고
    • Incidence and risks leading to cardiac arrest following emergency intubation [abstract]
    • Mort TC. Incidence and risks leading to cardiac arrest following emergency intubation [abstract]. Crit Care Med 1994;22:A137.
    • (1994) Crit Care Med , vol.22
    • Mort, T.C.1
  • 5
    • 0027672059 scopus 로고
    • Oesophageal intubation: An analysis of 2000 incident reports
    • Holland R, Webb RK, Runciman WB. Oesophageal intubation: an analysis of 2000 incident reports. Anaesth Intensive Care 1993;21:608-10.
    • (1993) Anaesth Intensive Care , vol.21 , pp. 608-610
    • Holland, R.1    Webb, R.K.2    Runciman, W.B.3
  • 6
    • 0031916998 scopus 로고    scopus 로고
    • Respiration in anaesthesia pathophysiology and clinical update
    • Wilson CW, Benumof JL. Respiration in anaesthesia pathophysiology and clinical update. Anesth Clin North Am 1998;16:29-75.
    • (1998) Anesth Clin North Am , vol.16 , pp. 29-75
    • Wilson, C.W.1    Benumof, J.L.2
  • 7
    • 0028284854 scopus 로고
    • Accidental oesophageal intubation
    • Clyburn P, Rosen M. Accidental oesophageal intubation. Br J Anaesth 1994;73:55-63.
    • (1994) Br J Anaesth , vol.73 , pp. 55-63
    • Clyburn, P.1    Rosen, M.2
  • 8
    • 0027978635 scopus 로고
    • Oesophageal intubation can be undetected by auscultation of the chest
    • Andersen KH, Schultz-Lebahn T. Oesophageal intubation can be undetected by auscultation of the chest. Acta Anaesthesiol Scand 1994;38:580-2.
    • (1994) Acta Anaesthesiol Scand , vol.38 , pp. 580-582
    • Andersen, K.H.1    Schultz-Lebahn, T.2
  • 9
    • 0024789102 scopus 로고
    • Assessing the position of the tracheal tube. The reality of different methods
    • Andersen KH, Registrar A, Hald A. Assessing the position of the tracheal tube. The reality of different methods. Anaesthesia 1989;44:984-5.
    • (1989) Anaesthesia , vol.44 , pp. 984-985
    • Andersen, K.H.1    Registrar, A.2    Hald, A.3
  • 10
    • 0029036166 scopus 로고
    • Condensation on tracheal tubes is commonly seen with oesophageal intubation
    • Haridas RP. Condensation on tracheal tubes is commonly seen with oesophageal intubation. Br J Anaesth 1995;75:115-6.
    • (1995) Br J Anaesth , vol.75 , pp. 115-116
    • Haridas, R.P.1
  • 11
    • 0025064183 scopus 로고
    • Radiographic detection of esophageal malposition of endotracheal tubes
    • Smith GM, Reed JC, Choplin RH. Radiographic detection of esophageal malposition of endotracheal tubes. AJR 1990;154:23-6.
    • (1990) AJR , vol.154 , pp. 23-26
    • Smith, G.M.1    Reed, J.C.2    Choplin, R.H.3
  • 13
    • 0026538036 scopus 로고
    • Multicenter study of a portable, hand size, calorimetric end-tidal carbon dioxide detection device
    • Ornato JP, Shipley JP, Racht EM, et al. Multicenter study of a portable, hand size, calorimetric end-tidal carbon dioxide detection device. Ann Emerg Med 1992;21:518-23.
    • (1992) Ann Emerg Med , vol.21 , pp. 518-523
    • Ornato, J.P.1    Shipley, J.P.2    Racht, E.M.3
  • 14
    • 0035099882 scopus 로고    scopus 로고
    • Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation
    • Li J. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation. J Emerg Med 2001;20:223-9.
    • (2001) J Emerg Med , vol.20 , pp. 223-229
    • Li, J.1
  • 16
    • 0032792408 scopus 로고    scopus 로고
    • Verification of endotracheal tube placement following intubation
    • O'Connor RE, Swor RA. Verification of endotracheal tube placement following intubation. Prehosp Emerg Care 1999;3:248-50.
    • (1999) Prehosp Emerg Care , vol.3 , pp. 248-250
    • O'Connor, R.E.1    Swor, R.A.2
  • 17
    • 0026667714 scopus 로고
    • The esophageal detector device: A rapid and accurate method for assessing tracheal versus esophageal intubation in the porcine model
    • Wee MYK. The esophageal detector device: a rapid and accurate method for assessing tracheal versus esophageal intubation in the porcine model. Ann Emerg Med 1992;21:1073-6.
    • (1992) Ann Emerg Med , vol.21 , pp. 1073-1076
    • Wee, M.Y.K.1
  • 18
    • 0024550719 scopus 로고
    • The esophageal detector device
    • Williams KN, Nunn FJ. The esophageal detector device. Anaesthesia 1989;44:412-4.
    • (1989) Anaesthesia , vol.44 , pp. 412-414
    • Williams, K.N.1    Nunn, F.J.2
  • 19
    • 0035102481 scopus 로고    scopus 로고
    • A prospective multicenter trial testing the SCOTI device for confirmation of endotracheal tube placement
    • Li J. A prospective multicenter trial testing the SCOTI device for confirmation of endotracheal tube placement. J Emerg Med 2001;20:231-9.
    • (2001) J Emerg Med , vol.20 , pp. 231-239
    • Li, J.1
  • 20
    • 0032820217 scopus 로고    scopus 로고
    • The esophageal detector device is unreliable when the stomach has been ventilated
    • Andres AH, Langenstein H. The esophageal detector device is unreliable when the stomach has been ventilated. Anesthesiology 1999;91:566-8.
    • (1999) Anesthesiology , vol.91 , pp. 566-568
    • Andres, A.H.1    Langenstein, H.2
  • 21
    • 0031948445 scopus 로고    scopus 로고
    • The self-inflating bulb to detect esophageal intubation during emergency airway management
    • Kasper CL, Deem S. The self-inflating bulb to detect esophageal intubation during emergency airway management. Anaesthesiology 1998;88:898-902.
    • (1998) Anaesthesiology , vol.88 , pp. 898-902
    • Kasper, C.L.1    Deem, S.2
  • 22
    • 0029940144 scopus 로고    scopus 로고
    • Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation
    • Bozeman WP, Hexter D, Liang HK, Kelen GD. Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation. Ann Emerg Med 1996;27:595-9.
    • (1996) Ann Emerg Med , vol.27 , pp. 595-599
    • Bozeman, W.P.1    Hexter, D.2    Liang, H.K.3    Kelen, G.D.4
  • 23
    • 0031007604 scopus 로고    scopus 로고
    • Out-of-hospital experience with the syringe esophageal detector device
    • Pelucio M, Halligan L, Dhindsa H. Out-of-hospital experience with the syringe esophageal detector device. Acad Emerg Med 1997;4:563-8.
    • (1997) Acad Emerg Med , vol.4 , pp. 563-568
    • Pelucio, M.1    Halligan, L.2    Dhindsa, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.