메뉴 건너뛰기




Volumn 50, Issue 4 II, 2003, Pages 809-819

Study of hole-type gas multiplication structures for portal imaging and other high count rate applications

Author keywords

Camillary plates; GEM; High counting rate; Portal imaging

Indexed keywords

GAMMA RAYS; MEDICAL IMAGING; PHOTONS; X RAYS;

EID: 0042928284     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2003.814562     Document Type: Conference Paper
Times cited : (53)

References (26)
  • 1
    • 0020151626 scopus 로고
    • Medical positron imaging with a dense drift space multiwire proportional chamber
    • Aug.
    • A. Del Guerra, C. Lim, D. Ortendahl, and V. Perez-Mendez, "Medical positron imaging with a dense drift space multiwire proportional chamber," IEEE Trans. Med. Imaging, vol. MI-1, pp. 4-11, Aug. 1982.
    • (1982) IEEE Trans. Med. Imaging , vol.MI-1 , pp. 4-11
    • Del Guerra, A.1    Lim, C.2    Ortendahl, D.3    Perez-Mendez, V.4
  • 2
    • 0030169844 scopus 로고    scopus 로고
    • A new type of proportional counter using a capillary plate
    • H. Sakurai, T. Tamura, S. Gunji, and M. Noma, "A new type of proportional counter using a capillary plate," Nucl. Instrum. Methods, vol. A374, pp. 341-344, 1996.
    • (1996) Nucl. Instrum. Methods , vol.A374 , pp. 341-344
    • Sakurai, H.1    Tamura, T.2    Gunji, S.3    Noma, M.4
  • 3
    • 0031074683 scopus 로고    scopus 로고
    • GEM: A new concept for electron multiplication in gaseous detectors
    • F. Sauli, "GEM: A new concept for electron multiplication in gaseous detectors," Nucl. Instrum. Methods, vol. A386, pp. 531-534, 1997.
    • (1997) Nucl. Instrum. Methods , vol.A386 , pp. 531-534
    • Sauli, F.1
  • 5
    • 0036494779 scopus 로고    scopus 로고
    • Discharge studies and prevention in the gas electron multiplier (GEM)
    • S. Bachmann et al., "Discharge studies and prevention in the gas electron multiplier (GEM)," Nucl. Instrum. Methods, vol. A479, pp. 294-308, 2002.
    • (2002) Nucl. Instrum. Methods , vol.A479 , pp. 294-308
    • Bachmann, S.1
  • 8
    • 0016486736 scopus 로고
    • The high-density multiwire drift chamber
    • A. Jeavons, G. Charpak, and B. Stubbs, "The High-density multiwire drift chamber," Nucl. Instrum. Methods, vol. 124, pp. 491-503, 1975.
    • (1975) Nucl. Instrum. Methods , vol.124 , pp. 491-503
    • Jeavons, A.1    Charpak, G.2    Stubbs, B.3
  • 10
    • 0034317033 scopus 로고    scopus 로고
    • Micro-gap parallel-plate chambers with porous secondary electron emitters
    • P. Fonte and V. Peskov, "Micro-gap parallel-plate chambers with porous secondary electron emitters," Nucl. Instrum. Methods, vol. A454, pp. 260-266, 2000.
    • (2000) Nucl. Instrum. Methods , vol.A454 , pp. 260-266
    • Fonte, P.1    Peskov, V.2
  • 11
    • 11644274109 scopus 로고
    • Secondary emission gaseous detectors: A new class of radiation imaging devices
    • A. Breskin, "Secondary emission gaseous detectors: A new class of radiation imaging devices," Nucl. Phys. B, vol. 44, pp. 351-363, 1995.
    • (1995) Nucl. Phys. B , vol.44 , pp. 351-363
    • Breskin, A.1
  • 12
    • 0036624320 scopus 로고    scopus 로고
    • Novel position-sensitive gaseous detectors with solid photocathodes
    • June
    • T. Francke, V. Peskov, I. Rodionov, and T. Sokolova, "Novel position-sensitive gaseous detectors with solid photocathodes," IEEE Trans. Nucl. Sci., vol. 49, pp. 977-983, June 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 977-983
    • Francke, T.1    Peskov, V.2    Rodionov, I.3    Sokolova, T.4
  • 13
    • 0036475187 scopus 로고    scopus 로고
    • Detection of the primary scintillation light from dense Ar, Kr and Xe with novel photosensitive gaseous detectors
    • L. Periale et al., "Detection of the primary scintillation light from dense Ar, Kr and Xe with novel photosensitive gaseous detectors," Nucl. Instrum. Methods, vol. A478, pp. 377-383, 2002.
    • (2002) Nucl. Instrum. Methods , vol.A478 , pp. 377-383
    • Periale, L.1
  • 16
    • 0032298793 scopus 로고    scopus 로고
    • Rate and gain limitations of MSGC's and MGC's combined with GEM and other preamplification structures
    • P. Fonte, V. Peskov, and B. Ramsey, "Rate and gain limitations of MSGC's and MGC's combined with GEM and other preamplification structures," Nucl. Instrum. Methods, vol. A439, pp. 405-409, 1998.
    • (1998) Nucl. Instrum. Methods , vol.A439 , pp. 405-409
    • Fonte, P.1    Peskov, V.2    Ramsey, B.3
  • 18
    • 0017499171 scopus 로고
    • On some factors controlling highaccuracy measurements of X-ray quanta positions with multiwire proportional chambers
    • G. Charpak, F. Sauli, and R. Kahn, "On some factors controlling highaccuracy measurements of X-ray quanta positions with multiwire proportional chambers," Nucl. Instrum. Methods, vol. 152, pp. 185-190, 1978.
    • (1978) Nucl. Instrum. Methods , vol.152 , pp. 185-190
    • Charpak, G.1    Sauli, F.2    Kahn, R.3
  • 19
    • 0033321430 scopus 로고    scopus 로고
    • The fundamental limitations of high-rate gaseous detectors
    • June
    • P. Fonte, V. Peskov, and B. Ramsey, "The fundamental limitations of high-rate gaseous detectors," IEEE Trans. Nucl. Sci., vol. 46, pp. 321-325, June 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 321-325
    • Fonte, P.1    Peskov, V.2    Ramsey, B.3
  • 21
    • 0036703227 scopus 로고    scopus 로고
    • Sporadic electron jets from cathodes - The main break down triggering mechanism in gaseous detectors
    • Aug.
    • C. Iacobaeus, M. Danielsson, P. Fonte, T. Francke, J. Ostling, and V. Peskov, "Sporadic electron jets from cathodes - The main break down triggering mechanism in gaseous detectors," IEEE Trans. Nucl. Sci., vol. 49, pp. 1622-1628, Aug. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 1622-1628
    • Iacobaeus, C.1    Danielsson, M.2    Fonte, P.3    Francke, T.4    Ostling, J.5    Peskov, V.6
  • 25
    • 0003849963 scopus 로고
    • Drift and diffusion of electrons in gases: A compilation
    • A. Peisert and F. Sauli, "Drift and Diffusion of Electrons in Gases: A Compilation," CERN Yellow Rep. CERN 84-08, 1984.
    • (1984) CERN Yellow Rep. , vol.CERN 84 , Issue.8
    • Peisert, A.1    Sauli, F.2
  • 26
    • 0032178820 scopus 로고    scopus 로고
    • A study of breakdown limits in microstrip gas counters with preamplification structures
    • P. Fonte, V. Peskov, and B. D. Ramsey, "A study of breakdown limits in microstrip gas counters with preamplification structures," Nucl. Instrum. Methods, vol. A416, pp. 23-31, 1998.
    • (1998) Nucl. Instrum. Methods , vol.A416 , pp. 23-31
    • Fonte, P.1    Peskov, V.2    Ramsey, B.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.