Volumn 95, Issue 3, 2003, Pages 1153-1158

Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension

Author keywords

Animal study; Radioactive microspheres

Indexed keywords

MICROSPHERE;

EID: 0042924190     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/japplphysiol.00299.2003     Document Type: Article
Times cited : (13)

References (46)
  • 1
    • 0021671523 scopus 로고
    • Blood flow in rabbit osteotomies studied with radioactive microspheres
    • Aalto K and Slatis P. Blood flow in rabbit osteotomies studied with radioactive microspheres. Acta Orthop Scand 55: 637-639, 1984.
    • (1984) Acta Orthop Scand , vol.55 , pp. 637-639
    • Aalto, K.1    Slatis, P.2
  • 2
    • 0037971243 scopus 로고    scopus 로고
    • Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample processing procedure
    • Anetzberger H, Thein E, Walli AK, and Messmer K. Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample processing procedure. Eur Surg Res 35: 337-345, 2003.
    • (2003) Eur Surg Res , vol.35 , pp. 337-345
    • Anetzberger, H.1    Thein, E.2    Walli, A.K.3    Messmer, K.4
  • 4
    • 0019016514 scopus 로고
    • Left ventricular cannulation for microsphere estimation of rabbit renal blood flow
    • Bhattacharya J and Beilin LJ. Left ventricular cannulation for microsphere estimation of rabbit renal blood flow. Am J Physiol Heart Circ Physiol 238: H736-H739, 1980.
    • (1980) Am J Physiol Heart Circ Physiol , vol.238
    • Bhattacharya, J.1    Beilin, L.J.2
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM and Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310, 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0014787090 scopus 로고
    • Arteriolar blockade: A method of measuring blood flow rates in the skeleton
    • Brookes M. Arteriolar blockade: a method of measuring blood flow rates in the skeleton. J Anat 106: 557-563, 1970.
    • (1970) J Anat , vol.106 , pp. 557-563
    • Brookes, M.1
  • 9
    • 0021082067 scopus 로고
    • Hemodynamics of the juvenile dog knee in relation to increased venous outlet resistance
    • Bünger C, Bulow J, Hjermind J, and Harving S. Hemodynamics of the juvenile dog knee in relation to increased venous outlet resistance. Pflügers Arch 399: 129-133, 1983.
    • (1983) Pflügers Arch , vol.399 , pp. 129-133
    • Bünger, C.1    Bulow, J.2    Hjermind, J.3    Harving, S.4
  • 10
    • 0004463924 scopus 로고
    • A study of blood flow to bone and marrow by a method of venous effluent collection
    • Cumming JD. A study of blood flow to bone and marrow by a method of venous effluent collection. J Physiol 162: 13-20, 1962.
    • (1962) J Physiol , vol.162 , pp. 13-20
    • Cumming, J.D.1
  • 11
    • 0023544770 scopus 로고
    • The effect of sympathectomy on blood flow in bone. Regional distribution and effect over time
    • Davis RF, Jones LC, and Hungerford DS. The effect of sympathectomy on blood flow in bone. Regional distribution and effect over time. J Bone Joint Surg Am 69: 1384-1390, 1987.
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 1384-1390
    • Davis, R.F.1    Jones, L.C.2    Hungerford, D.S.3
  • 13
    • 0035083323 scopus 로고    scopus 로고
    • Selective reduction of bone blood flow by short-term treatment with high-dose methylprednisolone. An experimental study in pigs
    • Drescher W, Schneider T, Becker C, Hobolth J, Ruther W, Hansen ES, and Bünger C. Selective reduction of bone blood flow by short-term treatment with high-dose methylprednisolone. An experimental study in pigs. J Bone Joint Surg Br 83: 274-277, 2001.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 274-277
    • Drescher, W.1    Schneider, T.2    Becker, C.3    Hobolth, J.4    Ruther, W.5    Hansen, E.S.6    Bünger, C.7
  • 15
    • 0025690394 scopus 로고
    • Responses of bone and joint blood vessels in cats and rabbits to electrical stimulation of nerves supplying the knee
    • Ferrell WR, Khoshbaten A, and Angerson WJ. Responses of bone and joint blood vessels in cats and rabbits to electrical stimulation of nerves supplying the knee. J Physiol 431: 677-687, 1990.
    • (1990) J Physiol , vol.431 , pp. 677-687
    • Ferrell, W.R.1    Khoshbaten, A.2    Angerson, W.J.3
  • 16
    • 0027231021 scopus 로고
    • Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
    • Glenny RW, Bernard S, and Brinkley M. Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. J Appl Physiol 74: 2585-2597, 1993.
    • (1993) J Appl Physiol , vol.74 , pp. 2585-2597
    • Glenny, R.W.1    Bernard, S.2    Brinkley, M.3
  • 17
    • 0018890901 scopus 로고
    • Regional distribution of circulating microspheres in the femur of the rabbit
    • Gregg PJ and Walder DN. Regional distribution of circulating microspheres in the femur of the rabbit. J Bone Joint Surg Br 62: 222-226, 1980.
    • (1980) J Bone Joint Surg Br , vol.62 , pp. 222-226
    • Gregg, P.J.1    Walder, D.N.2
  • 19
    • 0019596351 scopus 로고
    • Measurement of blood flow to bone and marrow in experimental animals by means of the microsphere technique
    • Gross PM, Marcus ML, and Heistad DD. Measurement of blood flow to bone and marrow in experimental animals by means of the microsphere technique. J Bone Joint Surg Am 63: 1028-1031, 1981.
    • (1981) J Bone Joint Surg Am , vol.63 , pp. 1028-1031
    • Gross, P.M.1    Marcus, M.L.2    Heistad, D.D.3
  • 21
    • 0025500073 scopus 로고
    • MIC-III - An integrated software package to support experiments using the radioactive microsphere technique
    • Gross W, Schosser R, and Messmer K. MIC-III - an integrated software package to support experiments using the radioactive microsphere technique. Comput Methods Programs Biomed 33: 65-85, 1990.
    • (1990) Comput Methods Programs Biomed , vol.33 , pp. 65-85
    • Gross, W.1    Schosser, R.2    Messmer, K.3
  • 22
    • 0026478065 scopus 로고
    • Blood flow and mechanical properties of healing bone. Femoral osteotomies studied in rats
    • Grundnes O and Reikeras O. Blood flow and mechanical properties of healing bone. Femoral osteotomies studied in rats. Acta Orthop Scand 63: 487-491, 1992.
    • (1992) Acta Orthop Scand , vol.63 , pp. 487-491
    • Grundnes, O.1    Reikeras, O.2
  • 23
    • 0025891256 scopus 로고
    • Arteriovenous shunting is not associated with venous congestion in bone. Knee tamponade studied with 15-μm and 50-μm microspheres in immature dogs
    • Hansen ES, Hjortdal VE, Kjolseth D, He SZ, Hoy K, Soballe K, and Bünger C. Arteriovenous shunting is not associated with venous congestion in bone. Knee tamponade studied with 15-μm and 50-μm microspheres in immature dogs. Acta Orthop Scand 62: 268-275, 1991.
    • (1991) Acta Orthop Scand , vol.62 , pp. 268-275
    • Hansen, E.S.1    Hjortdal, V.E.2    Kjolseth, D.3    He, S.Z.4    Hoy, K.5    Soballe, K.6    Bünger, C.7
  • 24
    • 0014297285 scopus 로고
    • Fundamental concepts in bone blood flow studies
    • Kane WJ. Fundamental concepts in bone blood flow studies. J Bone Joint Surg Am 50: 801-811, 1968.
    • (1968) J Bone Joint Surg Am , vol.50 , pp. 801-811
    • Kane, W.J.1
  • 25
    • 0014483626 scopus 로고
    • Blood flow to canine hind-limb bone, muscle, and skin. A quantitative method and its validation
    • Kane WJ and Grim E. Blood flow to canine hind-limb bone, muscle, and skin. A quantitative method and its validation. J Bone Joint Surg Am 51: 309-322, 1969.
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 309-322
    • Kane, W.J.1    Grim, E.2
  • 26
    • 0014848815 scopus 로고
    • Determination of cortical blood flow in rabbit femur by radioactive microspheres
    • Lunde PK and Michelsen K. Determination of cortical blood flow in rabbit femur by radioactive microspheres. Acta Physiol Scand 80: 39-44, 1970.
    • (1970) Acta Physiol Scand , vol.80 , pp. 39-44
    • Lunde, P.K.1    Michelsen, K.2
  • 27
    • 0028337414 scopus 로고
    • Canine bone blood flow measurements using serial microsphere injections
    • McGrory BJ, Moran CG, Bronk J, Weaver AL, and Wood MB. Canine bone blood flow measurements using serial microsphere injections. Clin Orthop 303: 264-279, 1994.
    • (1994) Clin Orthop , vol.303 , pp. 264-279
    • McGrory, B.J.1    Moran, C.G.2    Bronk, J.3    Weaver, A.L.4    Wood, M.B.5
  • 28
    • 85047692313 scopus 로고
    • Hemodynamics of the bone marrow circulation
    • Michelsen K. Hemodynamics of the bone marrow circulation. Acta Physiol Scand 73: 264-280, 1968.
    • (1968) Acta Physiol Scand , vol.73 , pp. 264-280
    • Michelsen, K.1
  • 30
    • 0033106345 scopus 로고    scopus 로고
    • Cerebral blood flow determinations using fluorescent microspheres: Variations on the sedimentation method validated
    • Powers KM, Schimmel C, Glenny RW, and Bernards CM. Cerebral blood flow determinations using fluorescent microspheres: variations on the sedimentation method validated. J Neurosci Methods 87: 159-165, 1999.
    • (1999) J Neurosci Methods , vol.87 , pp. 159-165
    • Powers, K.M.1    Schimmel, C.2    Glenny, R.W.3    Bernards, C.M.4
  • 31
    • 85047678005 scopus 로고
    • Developments in non-radioactive microsphere techniques for blood flow measurement
    • Prinzen FW and Glenny RW. Developments in non-radioactive microsphere techniques for blood flow measurement. Cardiovasc Res 28: 1467-1475, 1994.
    • (1994) Cardiovasc Res , vol.28 , pp. 1467-1475
    • Prinzen, F.W.1    Glenny, R.W.2
  • 33
    • 0027240405 scopus 로고
    • Bone blood flow in the rat using arteriolar blockade: Comparisons between labelled resin particles and microspheres
    • Revell WJ and Brookes M. Bone blood flow in the rat using arteriolar blockade: comparisons between labelled resin particles and microspheres. J Anat 182: 305-312, 1993.
    • (1993) J Anat , vol.182 , pp. 305-312
    • Revell, W.J.1    Brookes, M.2
  • 34
    • 0034984758 scopus 로고    scopus 로고
    • Extending fluorescent microsphere methods for regional organ blood flow to 13 simultaneous colors
    • Schimmel C, Frazer D, and Glenny RW. Extending fluorescent microsphere methods for regional organ blood flow to 13 simultaneous colors. Am J Physiol Heart Circ Physiol 280: H2496-H2506, 2001.
    • (2001) Am J Physiol Heart Circ Physiol , vol.280
    • Schimmel, C.1    Frazer, D.2    Glenny, R.W.3
  • 35
    • 0034646486 scopus 로고    scopus 로고
    • Validation of automated spectrofluorimetry for measurement of regional organ perfusion using fluorescent microspheres
    • Schimmel C, Frazer D, Huckins SR, and Glenny RW. Validation of automated spectrofluorimetry for measurement of regional organ perfusion using fluorescent microspheres. Comput Methods Programs Biomed 62: 115-125, 2000.
    • (2000) Comput Methods Programs Biomed , vol.62 , pp. 115-125
    • Schimmel, C.1    Frazer, D.2    Huckins, S.R.3    Glenny, R.W.4
  • 36
    • 0014298496 scopus 로고
    • Physiology of blood circulation of bone
    • Shim SS. Physiology of blood circulation of bone. J Bone Joint Surg Am 50: 812-824, 1968.
    • (1968) J Bone Joint Surg Am , vol.50 , pp. 812-824
    • Shim, S.S.1
  • 37
    • 0013941991 scopus 로고
    • Bone blood flow in the limb following complete sciatic nerve section
    • Shim SS, Copp DH, and Patterson FP. Bone blood flow in the limb following complete sciatic nerve section. Surg Gynecol Obstet 123: 333-335, 1966.
    • (1966) Surg Gynecol Obstet , vol.123 , pp. 333-335
    • Shim, S.S.1    Copp, D.H.2    Patterson, F.P.3
  • 38
    • 0014097664 scopus 로고
    • An indirect method of bone blood-flow measurement based on the bone clearance of a circulating bone-seeking radioisotope
    • Shim SS, Copp DH, and Patterson FP. An indirect method of bone blood-flow measurement based on the bone clearance of a circulating bone-seeking radioisotope. J Bone Joint Surg Am 49: 693-702, 1967.
    • (1967) J Bone Joint Surg Am , vol.49 , pp. 693-702
    • Shim, S.S.1    Copp, D.H.2    Patterson, F.P.3
  • 39
    • 0035112737 scopus 로고    scopus 로고
    • Physiological and mechanical adaptation of periarticular cancellous bone after joint ligament injury
    • Shymkiw RC, Bray RC, Boyd SK, Kantzas A, and Zernicke RF. Physiological and mechanical adaptation of periarticular cancellous bone after joint ligament injury. J Appl Physiol 90: 1083-1087, 2001.
    • (2001) J Appl Physiol , vol.90 , pp. 1083-1087
    • Shymkiw, R.C.1    Bray, R.C.2    Boyd, S.K.3    Kantzas, A.4    Zernicke, R.F.5
  • 40
    • 0015850762 scopus 로고
    • Sequential changes in distribution of cardiac output in hemorrhagic shock
    • Slater GI, Vladeck BC, Bassin R, Kark AE, and Shoemaker WC. Sequential changes in distribution of cardiac output in hemorrhagic shock. Surgery 73: 714-722, 1973.
    • (1973) Surgery , vol.73 , pp. 714-722
    • Slater, G.I.1    Vladeck, B.C.2    Bassin, R.3    Kark, A.E.4    Shoemaker, W.C.5
  • 41
    • 0030723864 scopus 로고    scopus 로고
    • Use of an automated fluorescent microsphere method to measure regional blood flow in the fetal lamb
    • Tan W, Riggs KW, Thies RL, and Rurak DW. Use of an automated fluorescent microsphere method to measure regional blood flow in the fetal lamb. Can J Physiol Pharmacol 75: 959-968, 1997.
    • (1997) Can J Physiol Pharmacol , vol.75 , pp. 959-968
    • Tan, W.1    Riggs, K.W.2    Thies, R.L.3    Rurak, D.W.4
  • 42
    • 0035998983 scopus 로고    scopus 로고
    • Comparison of regional blood flow values measured by radioactive and fluorescent microspheres
    • Thein E, Raab S, Harris AG, Kleen M, Habler O, Meisner F, and Messmer K. Comparison of regional blood flow values measured by radioactive and fluorescent microspheres. Eur Surg Res 34: 215-223, 2002.
    • (2002) Eur Surg Res , vol.34 , pp. 215-223
    • Thein, E.1    Raab, S.2    Harris, A.G.3    Kleen, M.4    Habler, O.5    Meisner, F.6    Messmer, K.7
  • 43
    • 0033990647 scopus 로고    scopus 로고
    • Automation of the use of fluorescent microspheres for the determination of blood flow
    • Thein E, Raab S, Harris AG, and Messmer K. Automation of the use of fluorescent microspheres for the determination of blood flow. Comput Methods Programs Biomed 61: 11-21, 2000.
    • (2000) Comput Methods Programs Biomed , vol.61 , pp. 11-21
    • Thein, E.1    Raab, S.2    Harris, A.G.3    Messmer, K.4
  • 45
    • 0030833607 scopus 로고    scopus 로고
    • Validation of the multiple colored microsphere technique for regional blood flow measurements in newborn piglets
    • Walter B, Bauer R, Gaser E, and Zwiener U. Validation of the multiple colored microsphere technique for regional blood flow measurements in newborn piglets. Basic Res Cardiol 92: 191-200, 1997.
    • (1997) Basic Res Cardiol , vol.92 , pp. 191-200
    • Walter, B.1    Bauer, R.2    Gaser, E.3    Zwiener, U.4
  • 46
    • 0015393772 scopus 로고
    • Bone circulation in hemorrhagic shock. An experimental study
    • Yu W, Shim SS, and Hawk HE. Bone circulation in hemorrhagic shock. An experimental study. J Bone Joint Surg Am 54: 1157-1166, 1972.
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 1157-1166
    • Yu, W.1    Shim, S.S.2    Hawk, H.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.