메뉴 건너뛰기




Volumn 5030 I, Issue , 2003, Pages 445-458

An overall X-ray system simulation model developed for system design and image quality versus patient dose optimization

Author keywords

Figure of merit; Image quality; Optimization; Patient dose; Simulation; X ray system

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DOSIMETRY; IMAGE PROCESSING; IMAGE QUALITY; OPTIMIZATION; PARETO PRINCIPLE; X RAY RADIOGRAPHY;

EID: 0042877328     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.479950     Document Type: Conference Paper
Times cited : (11)

References (18)
  • 1
    • 84970400213 scopus 로고
    • Über das kontinuierliche röntgenspektrum
    • H. Kulenkampff, "Über das kontinuierliche Röntgenspektrum" Ann. Phys. Leipzig 69 548-596 (1922)
    • (1922) Ann. Phys. Leipzig , vol.69 , pp. 548-596
    • Kulenkampff, H.1
  • 2
    • 0000599583 scopus 로고
    • On the theory of X-ray absorption of the continuous X-ray spectrum
    • H.A. Kramers, " On the theory of X-ray absorption of the continuous X-ray spectrum" Philos. Mag. 46 836-871 (1923)
    • (1923) Philos. Mag. , vol.46 , pp. 836-871
    • Kramers, H.A.1
  • 3
    • 0025756532 scopus 로고
    • Semiemperical model for generating tungsten target X-ray spectra
    • D.M. Tucker, G.T. Barnes, D.P. Chakraborty "Semiemperical model for generating tungsten target X-ray spectra" Med. Phys. 18 (2) 211-218 (1991)
    • (1991) Med. Phys. , vol.18 , Issue.2 , pp. 211-218
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3
  • 5
    • 0003884120 scopus 로고
    • Measurement of dose equivalents from external photon and electron radiations
    • International Commission on Radiation Units and Measurements, Bethesda
    • ICRU Report 47, Measurement of dose equivalents from external photon and electron radiations, (International Commission on Radiation Units and Measurements, Bethesda), 1992.
    • (1992) ICRU Report , vol.47
  • 6
    • 0015667930 scopus 로고
    • Absorption and noise in X-ray phosphors
    • R.K. Swank, "Absorption and noise in X-ray phosphors" J. Appl. Phys. 44 (9) 4199-4203 (1983)
    • (1983) J. Appl. Phys. , vol.44 , Issue.9 , pp. 4199-4203
    • Swank, R.K.1
  • 9
    • 0034870333 scopus 로고    scopus 로고
    • Temporal artefacts in flat dynamic X-ray detectors
    • M. Overdick, T. Soif, H.-A. Wischmann, "Temporal artefacts in flat dynamic X-ray detectors", SPIE 4320 47-58 (2001)
    • (2001) SPIE , vol.4320 , pp. 47-58
    • Overdick, M.1    Soif, T.2    Wischmann, H.-A.3
  • 11
    • 0037253990 scopus 로고    scopus 로고
    • Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    • J.T. Dobbins III, E Samei, H.G. Chotas, R.J. Warp, A.H. Baydush, C.E. Floyd, C.E. Ravin, "Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector", Radiol. 226 221-230 (2003)
    • (2003) Radiol. , vol.226 , pp. 221-230
    • Dobbins J.T. III1    Samei, E.2    Chotas, H.G.3    Warp, R.J.4    Baydush, A.H.5    Floyd, C.E.6    Ravin, C.E.7
  • 12
    • 0000356133 scopus 로고    scopus 로고
    • Signal-to-noise optimization of medical imaging systems
    • I.A. Cunningham, R. Shaw, "Signal-to-noise optimization of medical imaging systems", J. Opt. Soc. Am. 16 (3), 621-632 (1999)
    • (1999) J. Opt. Soc. Am. , vol.16 , Issue.3 , pp. 621-632
    • Cunningham, I.A.1    Shaw, R.2
  • 13
    • 0028954458 scopus 로고
    • Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test object use in television fluoroscopy
    • J.H. Launders, S. McArdle, A. Workman, A.R. Cowen, "Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test object use in television fluoroscopy", Br. J. Radiol. 68 70-77 (1995)
    • (1995) Br. J. Radiol. , vol.68 , pp. 70-77
    • Launders, J.H.1    McArdle, S.2    Workman, A.3    Cowen, A.R.4
  • 14
    • 0041961358 scopus 로고
    • X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
    • IEC international standard 60336 ed 3.0, X-ray tube assemblies for medical diagnosis - Characteristics of focal spots (1993)
    • (1993) IEC International Standard 60336 ed 3.0
  • 15
    • 0026443715 scopus 로고
    • Parametrized X-ray absorption in diagnostic radiology from Monte Carlo calculations: Implications for X-ray detector design
    • J.M. Boone, "Parametrized X-ray absorption in diagnostic radiology from Monte Carlo calculations: Implications for X-ray detector design", Med. Phys. 16 (6) 1467-1473 (1992)
    • (1992) Med. Phys. , vol.16 , Issue.6 , pp. 1467-1473
    • Boone, J.M.1
  • 16
    • 0032964047 scopus 로고    scopus 로고
    • A search for improved technique factors in paediatric fluoroscopy
    • M.J. Tapiovaara, M. Sandborg, D.R. Dance, "A search for improved technique factors in paediatric fluoroscopy", Phys. Med. Biol. 44 537-559 (1999)
    • (1999) Phys. Med. Biol. , vol.44 , pp. 537-559
    • Tapiovaara, M.J.1    Sandborg, M.2    Dance, D.R.3
  • 17
    • 0003958372 scopus 로고
    • Italian; French translation, 1909, English translation, 1971
    • V. Pareto, Manual of political economy, (Italian; French translation, 1909, English translation, 1971) (p.261), http://cepa.newschool.edu/het/essays/paretian/paretoptimal.htm (1906)
    • (1906) Manual of Political Economy , pp. 261
    • Pareto, V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.