메뉴 건너뛰기




Volumn 18, Issue 3, 2003, Pages 353-359

Sub-acute changes in lesion conspicuity and geometry following MR-guided radiofrequency ablation

Author keywords

Contrast enhanced T1 weighted images; Image analysis; Interventional magnetic resonance imaging; Medical image processing; Radiofrequency thermal ablation; Segmentation; T2 weighted images

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM PENTETATE MEGLUMINE; NUCLEAR MAGNETIC RESONANCE IMAGING AGENT;

EID: 0042829296     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10352     Document Type: Article
Times cited : (23)

References (15)
  • 1
    • 0035041810 scopus 로고    scopus 로고
    • Radiofrequency tissue ablation: Physical principles and techniques for increasing coagulation necrosis
    • Goldberg SN, Gazelle GS. Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. Hepatogastroenterology 2001;48:359-367.
    • (2001) Hepatogastroenterology , vol.48 , pp. 359-367
    • Goldberg, S.N.1    Gazelle, G.S.2
  • 2
    • 0031932248 scopus 로고    scopus 로고
    • Electric field and temperature distributions in RF thermal ablation: Comparison with gel experiments and liver imaging
    • Cheng YC, Brown RW, Chung YC, et al. Electric field and temperature distributions in RF thermal ablation: comparison with gel experiments and liver imaging. J Magn Reson Imaging 1998;8:70-76.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 70-76
    • Cheng, Y.C.1    Brown, R.W.2    Chung, Y.C.3
  • 3
    • 0033814469 scopus 로고    scopus 로고
    • Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: A comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T
    • Aschoff AJ, Rafle N, Jesberger JA, Duerk JL, Lewin JS. Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: a comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T. J Magn Reson Imaging 2000;12:584-589.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 584-589
    • Aschoff, A.J.1    Rafle, N.2    Jesberger, J.A.3    Duerk, J.L.4    Lewin, J.S.5
  • 4
    • 0031446576 scopus 로고    scopus 로고
    • Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment: Preliminary ex vivo and in vivo results
    • Steiner P, Botnar R, Goldberg SN, Gazelle GS, Debatin JF. Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment: preliminary ex vivo and in vivo results. Invest Radiol 1997;32:671-678.
    • (1997) Invest Radiol , vol.32 , pp. 671-678
    • Steiner, P.1    Botnar, R.2    Goldberg, S.N.3    Gazelle, G.S.4    Debatin, J.F.5
  • 6
    • 0038787489 scopus 로고    scopus 로고
    • Three dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response
    • Breen MS, Lancaster TL, Lazebnik RS, Nour SG, Lewin JS, Wilson DL. Three dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response. J Magn Reson Imaging 2003;18:90-102.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 90-102
    • Breen, M.S.1    Lancaster, T.L.2    Lazebnik, R.S.3    Nour, S.G.4    Lewin, J.S.5    Wilson, D.L.6
  • 7
    • 0031404897 scopus 로고    scopus 로고
    • Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging
    • Chung YC, Duerk JL, Lewin JS. Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging. Invest Radiol 1997;32:466-474.
    • (1997) Invest Radiol , vol.32 , pp. 466-474
    • Chung, Y.C.1    Duerk, J.L.2    Lewin, J.S.3
  • 8
    • 0036789238 scopus 로고    scopus 로고
    • Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy
    • Lazebnik RS, Weinberg BD, Breen MS, Lewin JS, Wilson DL. Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy. Acad Radiol 2002;9:1128-1138.
    • (2002) Acad Radiol , vol.9 , pp. 1128-1138
    • Lazebnik, R.S.1    Weinberg, B.D.2    Breen, M.S.3    Lewin, J.S.4    Wilson, D.L.5
  • 9
    • 0031934807 scopus 로고    scopus 로고
    • Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility
    • Lewin JS, Connell CF, Duerk JL, et al. Interactive MRI-guided radiofrequency Interstitial thermal ablation of abdominal tumors: clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 1998;8:40-47.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 40-47
    • Lewin, J.S.1    Connell, C.F.2    Duerk, J.L.3
  • 10
    • 0035409402 scopus 로고    scopus 로고
    • MR imaging-histopathologic correlation of radiofrequency thermal ablation lesion in a rabbit liver model: Observation during acute and chronic stages
    • Lee JD, Lee JM, Kim SW, Kim CS, Mun WS. MR imaging-histopathologic correlation of radiofrequency thermal ablation lesion in a rabbit liver model: observation during acute and chronic stages. Korean J Radiol 2001;2:151-158.
    • (2001) Korean J Radiol , vol.2 , pp. 151-158
    • Lee, J.D.1    Lee, J.M.2    Kim, S.W.3    Kim, C.S.4    Mun, W.S.5
  • 11
    • 0031240184 scopus 로고    scopus 로고
    • A methodology for evaluation of boundary detection algorithms on medical images
    • Chalana V, Kim Y. A methodology for evaluation of boundary detection algorithms on medical images. IEEE Trans Med Imaging 2002;16:642-652.
    • (2002) IEEE Trans Med Imaging , vol.16 , pp. 642-652
    • Chalana, V.1    Kim, Y.2
  • 13
    • 0029294873 scopus 로고
    • Tissue ablation with radiofrequency: Effect of probe size, gauge, duration, and temperature on lesion volume
    • Goldberg SN, Gazelle GS, Dawson SL, Rittman WJ, Mueller PR, Rosenthal DI. Tissue ablation with radiofrequency: effect of probe size, gauge, duration, and temperature on lesion volume. Acad Radiol 1995;2:399-404.
    • (1995) Acad Radiol , vol.2 , pp. 399-404
    • Goldberg, S.N.1    Gazelle, G.S.2    Dawson, S.L.3    Rittman, W.J.4    Mueller, P.R.5    Rosenthal, D.I.6
  • 14
    • 0026954616 scopus 로고
    • MR imaging-histopathologic correlation of thermal injuries induced with interstitial Nd:YAG laser irradiation in the chronic model
    • Anzai Y, Lufkin RB, Hirschowitz S, Farahani K, Castro DJ. MR imaging-histopathologic correlation of thermal injuries induced with interstitial Nd:YAG laser irradiation in the chronic model. J Magn Reson Imaging 1992;2:671-678.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 671-678
    • Anzai, Y.1    Lufkin, R.B.2    Hirschowitz, S.3    Farahani, K.4    Castro, D.J.5
  • 15
    • 0042353808 scopus 로고    scopus 로고
    • Follow up findings of a phase II clinical trial of interactive MR-guided interstitial radiofrequency thermal ablation of primary kidney tumors
    • Honolulu
    • Lewin JS, Nour SG, Connell CF, Sulrnan A, Duerk JL, Resnick NI. Follow up findings of a phase II clinical trial of interactive MR-guided interstitial radiofrequency thermal ablation of primary kidney tumors. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002. p. 238.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM , pp. 238
    • Lewin, J.S.1    Nour, S.G.2    Connell, C.F.3    Sulrnan, A.4    Duerk, J.L.5    Resnick, N.I.6