메뉴 건너뛰기




Volumn 9, Issue 10, 2002, Pages 1128-1138

Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy

Author keywords

Magnetic resonance (MR), guidance; Magnetic resonance (MR), image processing; Phantoms; Radiofrequency (RF) ablation

Indexed keywords

GADOLINIUM PENTETATE MEGLUMINE;

EID: 0036789238     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1076-6332(03)80514-7     Document Type: Article
Times cited : (14)

References (22)
  • 1
    • 0030662573 scopus 로고    scopus 로고
    • Interventional magnetic resonance imaging
    • Lamb GM, Gedroyc WM. Interventional magnetic resonance imaging. Br J Radiol 1997; 70(spec no):S81-S88.
    • (1997) Br J Radiol , vol.70 , Issue.SPEC. NO.
    • Lamb, G.M.1    Gedroyc, W.M.2
  • 2
    • 0032748010 scopus 로고    scopus 로고
    • Interventional MR imaging: Concepts, systems, and applications in neuroradiology
    • Lewin JS. Interventional MR imaging: concepts, systems, and applications in neuroradiology. AJNR Am J Neuroradiol 1999; 20:735-748.
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 735-748
    • Lewin, J.S.1
  • 3
    • 0032768602 scopus 로고    scopus 로고
    • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: Demonstration of feasibility at 0.2 T
    • Merkle EM, Boll DT, Boaz T, et al. MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T. Magn Reson Med 1999; 42:141-149.
    • (1999) Magn Reson Med , vol.42 , pp. 141-149
    • Merkle, E.M.1    Boll, D.T.2    Boaz, T.3
  • 4
    • 0031446576 scopus 로고    scopus 로고
    • Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment: Preliminary ex vivo and in vivo results
    • Steiner P, Botnar R, Goldberg SN, Gazelle GS, Debatin JF. Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment: preliminary ex vivo and in vivo results. Invest Radiol 1997; 32:671-678.
    • (1997) Invest Radiol , vol.32 , pp. 671-678
    • Steiner, P.1    Botnar, R.2    Goldberg, S.N.3    Gazelle, G.S.4    Debatin, J.F.5
  • 5
    • 0031933092 scopus 로고    scopus 로고
    • Radio-frequency-induced thermoablation: Monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment
    • Steiner P, Botnar R, Dubno B, Zimmermann GG, Gazelle GS, Debatin JF. Radio-frequency-induced thermoablation: monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment. Radiology 1998; 206:803-810.
    • (1998) Radiology , vol.206 , pp. 803-810
    • Steiner, P.1    Botnar, R.2    Dubno, B.3    Zimmermann, G.G.4    Gazelle, G.S.5    Debatin, J.F.6
  • 6
    • 0033814469 scopus 로고    scopus 로고
    • Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: A comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T
    • Aschoff AJ, Rafie N, Jesberger JA, Duerk JL, Lewin JS. Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: a comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T. J Magn Reson Imaging 2000; 12:584-589.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 584-589
    • Aschoff, A.J.1    Rafie, N.2    Jesberger, J.A.3    Duerk, J.L.4    Lewin, J.S.5
  • 7
    • 0031933092 scopus 로고    scopus 로고
    • Radio-frequency-induced thermoablation: Monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment
    • Steiner P, Botnar R, Dubno B, Zimmermann GG, Gazelle GS, Debatin JF. Radio-frequency-induced thermoablation: monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment. Radiology 1998; 206:803-810.
    • (1998) Radiology , vol.206 , pp. 803-810
    • Steiner, P.1    Botnar, R.2    Dubno, B.3    Zimmermann, G.G.4    Gazelle, G.S.5    Debatin, J.F.6
  • 8
    • 0034875601 scopus 로고    scopus 로고
    • Three dimensional correlation of MR images to muscle tissue response for interventional MRI thermal ablation
    • Mun SK, ed. Visualization, display, and image-guided procedures
    • Breen MS, Lancaster TL, Lazebnik RS, et al. Three dimensional correlation of MR images to muscle tissue response for interventional MRI thermal ablation. In: Mun SK, ed. Visualization, display, and image-guided procedures. Proc SPIE Med Imaging 2001; 4319:211-220.
    • (2001) Proc SPIE Med Imaging , vol.4319 , pp. 211-220
    • Breen, M.S.1    Lancaster, T.L.2    Lazebnik, R.S.3
  • 9
    • 0031404897 scopus 로고    scopus 로고
    • Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging
    • Chung YC, Duerk JL, Lewin JS. Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging. Invest Radiol 1997; 32:466-474.
    • (1997) Invest Radiol , vol.32 , pp. 466-474
    • Chung, Y.C.1    Duerk, J.L.2    Lewin, J.S.3
  • 10
    • 0029294873 scopus 로고
    • Tissue ablation with radiofrequency: Effect of probe size, gauge, duration, and temperature on lesion volume
    • Goldberg SN, Gazelle GS, Dawson SL, Rittman WJ, Mueller PR, Rosenthal DI. Tissue ablation with radiofrequency: effect of probe size, gauge, duration, and temperature on lesion volume. Acad Radiol 1995; 2:399-404.
    • (1995) Acad Radiol , vol.2 , pp. 399-404
    • Goldberg, S.N.1    Gazelle, G.S.2    Dawson, S.L.3    Rittman, W.J.4    Mueller, P.R.5    Rosenthal, D.I.6
  • 11
    • 0031932248 scopus 로고    scopus 로고
    • Calculated RF electric field and temperature distributions in RF thermal ablation: Comparison with gel experiments and liver imaging
    • Cheng YC, Brown RW, Chung YC, et al. Calculated RF electric field and temperature distributions in RF thermal ablation: comparison with gel experiments and liver imaging. J Magn Reson Imaging 1998; 8:70-76.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 70-76
    • Cheng, Y.C.1    Brown, R.W.2    Chung, Y.C.3
  • 12
    • 0031934807 scopus 로고    scopus 로고
    • Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility
    • Lewin JS, Connell CF, Duerk JL, et al. Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 1998; 8:40-47.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 40-47
    • Lewin, J.S.1    Connell, C.F.2    Duerk, J.L.3
  • 14
    • 0030187101 scopus 로고    scopus 로고
    • A cooled needle electrode for radiofrequency tissue ablation: Thermodynamic aspects of improved performance compared with conventional needle design
    • Lorentzen T. A cooled needle electrode for radiofrequency tissue ablation: thermodynamic aspects of improved performance compared with conventional needle design. Acad Radiol 1996; 3:556-563.
    • (1996) Acad Radiol , vol.3 , pp. 556-563
    • Lorentzen, T.1
  • 15
    • 0032778383 scopus 로고    scopus 로고
    • Percutaneous radiofrequency tissue ablation: Optimization of pulsed-radiofrequency technique to increase coagulation necrosis
    • Goldberg SN, Stein MC, Gazelle GS, Sheiman RG, Kruskal JB, Clouse ME. Percutaneous radiofrequency tissue ablation: optimization of pulsed-radiofrequency technique to increase coagulation necrosis. J Vasc Interv Radiol 1999; 10:907-916.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 907-916
    • Goldberg, S.N.1    Stein, M.C.2    Gazelle, G.S.3    Sheiman, R.G.4    Kruskal, J.B.5    Clouse, M.E.6
  • 16
    • 0036190130 scopus 로고    scopus 로고
    • Radio-frequency tumor ablation: Internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model
    • Boehm T, Malich A, Goldberg SN, et al. Radio-frequency tumor ablation: internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model. Radiology 2002; 222:805-813.
    • (2002) Radiology , vol.222 , pp. 805-813
    • Boehm, T.1    Malich, A.2    Goldberg, S.N.3
  • 17
    • 85031438572 scopus 로고    scopus 로고
    • Thermal model for fast simulation during MRI guidance of RF tumor ablation
    • in press
    • Johnson PC, Saidel GM. Thermal model for fast simulation during MRI guidance of RF tumor ablation. Ann Biomed Eng (in press).
    • Ann Biomed Eng
    • Johnson, P.C.1    Saidel, G.M.2
  • 19
    • 0000764589 scopus 로고
    • Distance to an ellipsoid
    • Heckbert PS, ed. Boston, Mass: AP Professional
    • Hart JC. Distance to an ellipsoid. In: Heckbert PS, ed. Graphics gems IV. Boston, Mass: AP Professional, 1994; 113-119.
    • (1994) Graphics gems IV , pp. 113-119
    • Hart, J.C.1
  • 21
    • 0000873069 scopus 로고
    • A method for the solution of certain problems in least squares
    • Levenberg K. A method for the solution of certain problems in least squares. Q Appl Math 1944; 2:164-168.
    • (1944) Q Appl Math , vol.2 , pp. 164-168
    • Levenberg, K.1
  • 22
    • 0000169232 scopus 로고
    • An algorithm for least squares estimation of nonlinear parameters
    • Marquardt D. An algorithm for least squares estimation of nonlinear parameters. SIAM J Appl Math 1963; 11:431-441.
    • (1963) SIAM J Appl Math , vol.11 , pp. 431-441
    • Marquardt, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.