메뉴 건너뛰기




Volumn 36, Issue 1-6 SPEC., 2003, Pages 475-478

Performance of CR- 39® with addition of DOP (dioctylphthalate) for fast neutron dosimetry

Author keywords

CR 39 material; Neutron dosimetry; Quality assurance

Indexed keywords

DOSIMETRY; ETCHING; NEUTRON DETECTORS; POLYCARBONATES; QUALITY ASSURANCE;

EID: 0042536425     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4487(03)00175-6     Document Type: Conference Paper
Times cited : (10)

References (13)
  • 4
    • 0344836161 scopus 로고    scopus 로고
    • Energy losses of magnetic monopoles and dyons in scintillators, steamer tubes and nuclear track detectors
    • Derkaoui, J., Giacomelli, G., Lari, T., Mandrioli, G., Ouchrif, M., Patrizii, L., Popa, V., 1998. Energy losses of magnetic monopoles and dyons in scintillators, steamer tubes and nuclear track detectors. Astropart. Phys. DFUB-Bo 13/98.
    • (1998) Astropart. Phys. , vol.DFUB-BO 13-98
    • Derkaoui, J.1    Giacomelli, G.2    Lari, T.3    Mandrioli, G.4    Ouchrif, M.5    Patrizii, L.6    Popa, V.7
  • 6
    • 0036387419 scopus 로고    scopus 로고
    • CR-39 acceptance test and optimization for fast neutron dosimetry applications
    • Fantuzzi E., Morelli B., Falangi G., Patrizii L., Togo V. CR-39 acceptance test and optimization for fast neutron dosimetry applications. Radiat. Prot. Dosim. 101(1-4):2002;573-578.
    • (2002) Radiat. Prot. Dosim. , vol.101 , Issue.1-4 , pp. 573-578
    • Fantuzzi, E.1    Morelli, B.2    Falangi, G.3    Patrizii, L.4    Togo, V.5
  • 7
    • 0032590646 scopus 로고    scopus 로고
    • MACRO Collaboration. Search for magnetic monopoles and nuclearites with the MACRO nuclear track detector
    • Giacomelli G. MACRO Collaboration. Search for magnetic monopoles and nuclearites with the MACRO nuclear track detector. Radiat. Meas. 31:1999;605-608.
    • (1999) Radiat. Meas. , vol.31 , pp. 605-608
    • Giacomelli, G.1
  • 10
  • 11
    • 0042349535 scopus 로고    scopus 로고
    • Optimisation of chemical etching procedures and dosimetric performance evaluation of two different CR-39 detectors
    • Morelli, B., Vilela, E., Fantuzzi, E., 1998. Optimisation of chemical etching procedures and dosimetric performance evaluation of two different CR-39 detectors. Radioprotecciòn, N° Extraordinario-Mayo 1998, pp. 151-153.
    • (1998) Radioprotecciòn, N° Extraordinario-Mayo 1998 , pp. 151-153
    • Morelli, B.1    Vilela, E.2    Fantuzzi, E.3
  • 12
    • 0032767328 scopus 로고    scopus 로고
    • Dosimetric performance of the fast neutron dosemeter for ENEA Personal Dosimetry Service
    • Morelli B., Vilela E., Fantuzzi E. Dosimetric performance of the fast neutron dosemeter for ENEA Personal Dosimetry Service. Radiat. Prot. Dosim. 85(1-4):1999;105-108.
    • (1999) Radiat. Prot. Dosim. , vol.85 , Issue.1-4 , pp. 105-108
    • Morelli, B.1    Vilela, E.2    Fantuzzi, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.