메뉴 건너뛰기




Volumn 101, Issue 1-4, 2002, Pages 183-186

A personal neutron monitoring system based on CR-39 recoil proton track detectors: Assessment of Hp(10) using image process algorithms

Author keywords

[No Author keywords available]

Indexed keywords

CARBONIC ACID; DIETHYLENE GLYCOL;

EID: 0036390415     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a005963     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 0032767328 scopus 로고    scopus 로고
    • Dosimetric Performance of the Fast Neutron Dosemeter for ENEA Personal Dosimetry Service
    • Morelli, B., Vilela, E. and Fantuzzi, E. Dosimetric Performance of the Fast Neutron Dosemeter for ENEA Personal Dosimetry Service. Radiat. Prot. Dosim. 85(1-4), 105-108 (1999).
    • (1999) Radiat. Prot. Dosim , vol.85 , Issue.1-4 , pp. 105-108
    • Morelli, B.1    Vilela, E.2    Fantuzzi, E.3
  • 3
    • 0036387419 scopus 로고    scopus 로고
    • CR-39 Acceptance test and Optimisation for Fast Neutron Dosimetry Applications
    • (this issue)
    • Fantuzzi, E., Morelli, B., Falangi, G., Patrizii, L. and Togo, V. CR-39 Acceptance test and Optimisation for Fast Neutron Dosimetry Applications. Radiat. Prot. Dosim. 101(1-4), 575-580 (this issue) (2002).
    • (2002) Radiat. Prot. Dosim , vol.101 , Issue.1-4 , pp. 575-580
    • Fantuzzi, E.1    Morelli, B.2    Falangi, G.3    Patrizii, L.4    Togo, V.5
  • 4
    • 0003575760 scopus 로고    scopus 로고
    • Optimisation of Chemical Etching Procedures and Dosimetric Performance Evaluation of Two Different CR-39 Detectors
    • IV Congreso de Proteccion Radiologica de Paises Europeos del Mediterraneo Occidental. VII Comreso de la Sociedad Espanola de Proteccion Radiologica. Barcelona. RADIOPROTECCION, N° Extraordinario
    • Morelli, B., Vilela, E. and Fantuzzi, E. Optimisation of Chemical Etching Procedures and Dosimetric Performance Evaluation of Two Different CR-39 Detectors. IV Congreso de Proteccion Radiologica de Paises Europeos del Mediterraneo Occidental. VII Comreso de la Sociedad Espanola de Proteccion Radiologica. Barcelona. RADIOPROTECCION, N° Extraordinario (1998).
    • (1998)
    • Morelli, B.1    Vilela, E.2    Fantuzzi, E.3
  • 5
    • 0003653716 scopus 로고    scopus 로고
    • Reference Neutron Radiations - Part 1: Characteristics and Methods of Production
    • ISO 8259-1
    • ISO 8259-1. Reference Neutron Radiations - Part 1: Characteristics and Methods of Production (1997).
    • (1997)
  • 6
    • 0019395377 scopus 로고
    • 238Pu-Li Source
    • 238Pu-Li Source. Health Phys. 40, 345-350 (1981).
    • (1981) Health Phys , vol.40 , pp. 345-350
    • Bunge, P.J.1
  • 7
    • 4243450948 scopus 로고    scopus 로고
    • Field Parameters and Dosimetric Characteristics of a Fast Neutron Calibration Facility: Experimental and Monte Carlo Evaluations
    • Proceedings of the International Workshop on Neutron Field Spectrometry in Science, Technology and Radiation Protection, 4-8 June 2000, PISA. (in press)
    • Bedogni, R., Gualdrini, G. and Monteventi, F. Field Parameters and Dosimetric Characteristics of a Fast Neutron Calibration Facility: Experimental and Monte Carlo Evaluations. Proceedings of the International Workshop on Neutron Field Spectrometry in Science, Technology and Radiation Protection, 4-8 June 2000, PISA. Nucl. Instr. Meth. (in press).
    • Nucl. Instr. Meth
    • Bedogni, R.1    Gualdrini, G.2    Monteventi, F.3
  • 8
    • 0000025439 scopus 로고    scopus 로고
    • Absolute Experimental and Numerical Calibration of the 14 MeV Neutron Source at the Frascati Neutron Generator
    • Angelone, M., Pillon, M., Batistoni, P., Martini, M., Martone, M. and Vado, V. Absolute Experimental and Numerical Calibration of the 14 MeV Neutron Source at the Frascati Neutron Generator. Rev. Sci. Instrum. 67(6), (1996).
    • (1996) Rev. Sci. Instrum , vol.67 , Issue.6
    • Angelone, M.1    Pillon, M.2    Batistoni, P.3    Martini, M.4    Martone, M.5    Vado, V.6
  • 9
    • 0030894192 scopus 로고    scopus 로고
    • Etched Truck Size Distribution Induced by Broad Neutron Spectra in PADC
    • Jakes, J., Voigt, J. and Schraube, H. Etched Truck Size Distribution Induced by Broad Neutron Spectra in PADC. Radiat. Prot. Dosim. 70(1-4), 133-138 (1997).
    • (1997) Radiat. Prot. Dosim , vol.70 , Issue.1-4 , pp. 133-138
    • Jakes, J.1    Voigt, J.2    Schraube, H.3
  • 10
    • 0031663214 scopus 로고    scopus 로고
    • The Contribution of EURADOS and CENDOS to Etched Tratck Neutron Dosimetry: the Current Status in Europe
    • Harvey, J. R., Tanner, R. J., Alberts, W. G., Bartlett, D. T., Piesch, E. K. A. and Schraube, H. The Contribution of EURADOS and CENDOS to Etched Tratck Neutron Dosimetry: the Current Status in Europe. Radiat. Prot. Dosim. 77(4), 267-304 (1998).
    • (1998) Radiat. Prot. Dosim , vol.77 , Issue.4 , pp. 267-304
    • Harvey, J.R.1    Tanner, R.J.2    Alberts, W.G.3    Bartlett, D.T.4    Piesch, E.K.A.5    Schraube, H.6
  • 11
    • 61449126227 scopus 로고    scopus 로고
    • II Servizio di Dosimetria Personale Dell'Istituto per la Radioprotezione dell'ENEA
    • ENEA Report AMB/99/13
    • Fantuzzi, E. and Bonarelli, T. II Servizio di Dosimetria Personale Dell'Istituto per la Radioprotezione dell'ENEA. ENEA Report AMB/99/13 (1999).
    • (1999)
    • Fantuzzi, E.1    Bonarelli, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.