Volumn 14, Issue 3, 2003, Pages 245-251

Recent advances in magnetic resonance perfusion imaging of the lung

Author keywords

Chest; Lung; Magnetic resonance; Perfusion

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM PENTETATE MEGLUMINE;

EID: 0042414070     PISSN: 08993459     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002142-200306000-00005     Document Type: Review
Times cited : (11)

References (58)
  • 1
    • 0017295241 scopus 로고
    • The use of radioisotope techniques for the evaluation of patients with pulmonary disease
    • Wagner HN Jr. The use of radioisotope techniques for the evaluation of patients with pulmonary disease. Am Rev Respir Dis 1976;113: 203-218.
    • (1976) Am Rev Respir Dis , vol.113 , pp. 203-218
    • Wagner H.N., Jr.1
  • 2
    • 0033057471 scopus 로고    scopus 로고
    • Fast magnetic resonance imaging of the lung
    • Hatabu H, Chen Q, Stock KW, et al. Fast magnetic resonance imaging of the lung. Eur J Radiol 1999;29:114-132.
    • (1999) Eur J Radiol , vol.29 , pp. 114-132
    • Hatabu, H.1    Chen, Q.2    Stock, K.W.3
  • 4
    • 0026460816 scopus 로고
    • MR imaging of the lungs: Value of short TE spin-echo pulse sequences
    • Mayo JR, MacKay A, Muller NL. MR imaging of the lungs: Value of short TE spin-echo pulse sequences. AJR Am J Roentgenol 1992; 159:951-956.
    • (1992) AJR Am J Roentgenol , vol.159 , pp. 951-956
    • Mayo, J.R.1    MacKay, A.2    Muller, N.L.3
  • 5
    • 0033013455 scopus 로고    scopus 로고
    • MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence
    • Hatabu H, Gaa J, Tadamura E, et al. MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 1999;29:152-159.
    • (1999) Eur J Radiol , vol.29 , pp. 152-159
    • Hatabu, H.1    Gaa, J.2    Tadamura, E.3
  • 6
    • 0028910197 scopus 로고
    • Multi-slice, breathhold imaging of the lung with submillisecond echo times
    • Alsop DC, Hatabu H, Bonnet M, et al. Multi-slice, breathhold imaging of the lung with submillisecond echo times. Magn Reson Med 1995;33:678-682.
    • (1995) Magn Reson Med , vol.33 , pp. 678-682
    • Alsop, D.C.1    Hatabu, H.2    Bonnet, M.3
  • 7
    • 0032587625 scopus 로고    scopus 로고
    • T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging
    • Hatabu H, Alsop DC, Listerud J, et al. T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol 1999;29:245-252.
    • (1999) Eur J Radiol , vol.29 , pp. 245-252
    • Hatabu, H.1    Alsop, D.C.2    Listerud, J.3
  • 8
    • 0025876984 scopus 로고
    • Lung parenchyma: Projection reconstruction MR imaging
    • Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: Projection reconstruction MR imaging. Radiology 1991;179:777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    Macovski, A.3
  • 9
    • 0029760132 scopus 로고    scopus 로고
    • Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH
    • Hatabu H, Gaa I, Kim D, et al. Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH. Magn Reson Med 1996; 36:503-508.
    • (1996) Magn Reson Med , vol.36 , pp. 503-508
    • Hatabu, H.1    Gaa, I.2    Kim, D.3
  • 10
    • 0029745061 scopus 로고    scopus 로고
    • Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE
    • Hatabu H, Gaa J, Kim D, et al. Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE. AJR Am J Roentgenol 1996;167:653-655.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 653-655
    • Hatabu, H.1    Gaa, J.2    Kim, D.3
  • 11
    • 0035104550 scopus 로고    scopus 로고
    • Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
    • Goyen M, Laub G, Ladd ME, et al. Dynamic 3D MR angiography of the pulmonary arteries in under four seconds. J Magn Reson Imaging 2001;13:372-377.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 372-377
    • Goyen, M.1    Laub, G.2    Ladd, M.E.3
  • 12
    • 0036134060 scopus 로고    scopus 로고
    • Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imaging
    • Matsuoka S, Uchiyama K, Shima H, et al. Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imaging. J Magn Reson Imaging 2002;15:108-113.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 108-113
    • Matsuoka, S.1    Uchiyama, K.2    Shima, H.3
  • 13
    • 0032938791 scopus 로고    scopus 로고
    • Demonstration of gravity-dependent lung perfusion with contrast-enhanced magnetic resonance imaging
    • Stock KW, Chen Q, Levin D, et al. Demonstration of gravity-dependent lung perfusion with contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 1999;9:557-561.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 557-561
    • Stock, K.W.1    Chen, Q.2    Levin, D.3
  • 14
    • 0030939253 scopus 로고    scopus 로고
    • Diagnosis of pulmonary embolism with magnetic resonance angiography
    • Meaney JF, Weg JG, Chenevert TL, et al. Diagnosis of pulmonary embolism with magnetic resonance angiography. N Engl J Med 1997;336:1422-1427.
    • (1997) N Engl J Med , vol.336 , pp. 1422-1427
    • Meaney, J.F.1    Weg, J.G.2    Chenevert, T.L.3
  • 15
    • 0030934861 scopus 로고    scopus 로고
    • Pulmonary embolism: Detection with MR perfusion imaging of lung - A feasibility study
    • Amundsen T, Kvaerness J, Jones RA, et al. Pulmonary embolism: Detection with MR perfusion imaging of lung - A feasibility study. Radiology 1997;203:181-185.
    • (1997) Radiology , vol.203 , pp. 181-185
    • Amundsen, T.1    Kvaerness, J.2    Jones, R.A.3
  • 16
    • 0032929484 scopus 로고    scopus 로고
    • Prospective comparison of MR lung perfusion and lung scintigraphy
    • Berthezene Y, Croisille P, Wiart M, et al. Prospective comparison of MR lung perfusion and lung scintigraphy. J Magn Reson Imaging 1999;9:61-68.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 61-68
    • Berthezene, Y.1    Croisille, P.2    Wiart, M.3
  • 17
    • 0036199278 scopus 로고    scopus 로고
    • Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation-perfusion scintigraphy: An intra-modality and inter-modality agreement study
    • Amundsen T, Torheim G, Kvistad KA, et al. Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation-perfusion scintigraphy: An intra-modality and inter-modality agreement study. J Magn Reson Imaging 2002;15:386-394.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 386-394
    • Amundsen, T.1    Torheim, G.2    Kvistad, K.A.3
  • 18
    • 0036169088 scopus 로고    scopus 로고
    • Contrast-enhanced MR perfusion imaging and MR angiography: Utility for management of pulmonary arteriovenous malformations for embolotherapy
    • Ohno Y, Hatabu H, Takenaka D, et al. Contrast-enhanced MR perfusion imaging and MR angiography: Utility for management of pulmonary arteriovenous malformations for embolotherapy. Eur J Radiol 2002;41:136-146.
    • (2002) Eur J Radiol , vol.41 , pp. 136-146
    • Ohno, Y.1    Hatabu, H.2    Takenaka, D.3
  • 19
    • 0036270776 scopus 로고    scopus 로고
    • Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung
    • Iwasawa T, Saito K, Ogawa N, et al. Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung. J Magn Reson Imaging 2002;15:685-692.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 685-692
    • Iwasawa, T.1    Saito, K.2    Ogawa, N.3
  • 20
    • 0032735406 scopus 로고    scopus 로고
    • Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI
    • Hatabu H, Tadamura E, Levin DL, et al. Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI. Magn Reson Med 1999;42:1033-1038.
    • (1999) Magn Reson Med , vol.42 , pp. 1033-1038
    • Hatabu, H.1    Tadamura, E.2    Levin, D.L.3
  • 21
    • 0035099710 scopus 로고    scopus 로고
    • Quantification of pulmonary perfusion with MR imaging: Recent advances
    • Uematsu H, Levin DL, Hatabu H. Quantification of pulmonary perfusion with MR imaging: Recent advances. Eur J Radiol 2001;37: 155-163.
    • (2001) Eur J Radiol , vol.37 , pp. 155-163
    • Uematsu, H.1    Levin, D.L.2    Hatabu, H.3
  • 22
    • 0034958205 scopus 로고    scopus 로고
    • Evaluation of regional pulmonary perfusion using ultrafast magnetic resonance imaging
    • Levin DL, Chen Q, Zhang M, et al. Evaluation of regional pulmonary perfusion using ultrafast magnetic resonance imaging. Magn Reson Med 2001;46:166-171.
    • (2001) Magn Reson Med , vol.46 , pp. 166-171
    • Levin, D.L.1    Chen, Q.2    Zhang, M.3
  • 23
    • 0033067313 scopus 로고    scopus 로고
    • Clinical rationale for very-high-field (3.0 Tesla) functional magnetic resonance imaging
    • Thulborn KR. Clinical rationale for very-high-field (3.0 Tesla) functional magnetic resonance imaging. Top Magn Reson Imaging 1999; 10:37-50.
    • (1999) Top Magn Reson Imaging , vol.10 , pp. 37-50
    • Thulborn, K.R.1
  • 26
    • 0033810130 scopus 로고    scopus 로고
    • Ultra high resolution imaging of the human head at 8 tesla: 2K × 2K for Y2K
    • Robitaille PM, Abduljalil AM, Kangarlu A. Ultra high resolution imaging of the human head at 8 tesla: 2K × 2K for Y2K. J Comput Assist Tomogr 2000;24:2-8.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 2-8
    • Robitaille, P.M.1    Abduljalil, A.M.2    Kangarlu, A.3
  • 27
    • 0037300438 scopus 로고    scopus 로고
    • A direct comparison of signal behavior between 4.0 Tesla and 1.5 Tesla: A phantom study
    • Uematsu H, Dougherty L, Takahashi M, et al. A direct comparison of signal behavior between 4.0 Tesla and 1.5 Tesla: A phantom study. Eur J Radiol 2002;2002;45:154-159.
    • (2002) Eur J Radiol 2002 , vol.45 , pp. 154-159
    • Uematsu, H.1    Dougherty, L.2    Takahashi, M.3
  • 29
    • 0034759243 scopus 로고    scopus 로고
    • Pulmonary MR angiography with contrast agent at 4 Tesla: A preliminary result
    • Uematsu H, Dougherty L, Takahashi M, et al. Pulmonary MR angiography with contrast agent at 4 Tesla: A preliminary result. Magn Reson Med 2001;46:1028-1030.
    • (2001) Magn Reson Med , vol.46 , pp. 1028-1030
    • Uematsu, H.1    Dougherty, L.2    Takahashi, M.3
  • 30
    • 0041742225 scopus 로고    scopus 로고
    • Abdominal imaging at 4 Tesla MR system: A preliminary result
    • Uematsu H, Dougherty L, Takahashi M, et al. Abdominal imaging at 4 Tesla MR system: A preliminary result. Eur J Radiol 2003;47: 161-163.
    • (2003) Eur J Radiol , vol.47 , pp. 161-163
    • Uematsu, H.1    Dougherty, L.2    Takahashi, M.3
  • 31
    • 0028153930 scopus 로고
    • Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography
    • Edelman RR, Siewert B, Adamis M, et al. Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography. Magn Reson Med 1994;31:233-238.
    • (1994) Magn Reson Med , vol.31 , pp. 233-238
    • Edelman, R.R.1    Siewert, B.2    Adamis, M.3
  • 32
    • 0032980788 scopus 로고    scopus 로고
    • An attempt of pulmonary perfusion imaging utilizing ultrashort echo time turbo FLASH sequence with signal targeting and alternating radio-frequency (STAR)
    • Hatabu H, Wielopolski PA, Tadamura E. An attempt of pulmonary perfusion imaging utilizing ultrashort echo time turbo FLASH sequence with signal targeting and alternating radio-frequency (STAR). Eur J Radiol 1999;29:160-163.
    • (1999) Eur J Radiol , vol.29 , pp. 160-163
    • Hatabu, H.1    Wielopolski, P.A.2    Tadamura, E.3
  • 33
    • 0033756739 scopus 로고    scopus 로고
    • Noninvasive pulmonary perfusion imaging by STAR-HASTE sequence
    • Hatabu H, Tadamura E, Prasad PV, et al. Noninvasive pulmonary perfusion imaging by STAR-HASTE sequence. Magn Reson Med 2000;44:808-812.
    • (2000) Magn Reson Med , vol.44 , pp. 808-812
    • Hatabu, H.1    Tadamura, E.2    Prasad, P.V.3
  • 34
    • 0032945093 scopus 로고    scopus 로고
    • Perfusion imaging of the human lung using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER)
    • Mai VM, Hagspiel KD, Christopher JM, et al. Perfusion imaging of the human lung using flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER). Magn Reson Imaging 1999;17:355-361.
    • (1999) Magn Reson Imaging , vol.17 , pp. 355-361
    • Mai, V.M.1    Hagspiel, K.D.2    Christopher, J.M.3
  • 35
    • 0032928766 scopus 로고    scopus 로고
    • MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR
    • Mai VM, Berr SS. MR perfusion imaging of pulmonary parenchyma using pulsed arterial spin labeling techniques: FAIRER and FAIR. J Magn Reson Imaging 1999;9:483-487.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 483-487
    • Mai, V.M.1    Berr, S.S.2
  • 36
    • 0026653875 scopus 로고
    • Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation
    • Kwong KK, Belliveau JW, Chesler DA, et al. Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. Proc Natl Acad Sci U S A 1992;89:5675-5679.
    • (1992) Proc Natl Acad Sci U S A , vol.89 , pp. 5675-5679
    • Kwong, K.K.1    Belliveau, J.W.2    Chesler, D.A.3
  • 37
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping. Magn Reson Med 1995;34:293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 38
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • Buxton RB, Frank LR, Wong EC, et al. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med 1998;40:383-396.
    • (1998) Magn Reson Med , vol.40 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3
  • 40
    • 0032873341 scopus 로고    scopus 로고
    • Pulmonary perfusion: Respiratory-triggered three-dimensional MR imaging with arterial spin tagging - Preliminary results in healthy volunteers
    • Roberts DA, Gefter WB, Hirsch JA, et al. Pulmonary perfusion: Respiratory-triggered three-dimensional MR imaging with arterial spin tagging - Preliminary results in healthy volunteers. Radiology 1999;212:890-895.
    • (1999) Radiology , vol.212 , pp. 890-895
    • Roberts, D.A.1    Gefter, W.B.2    Hirsch, J.A.3
  • 41
    • 0034898676 scopus 로고    scopus 로고
    • Dynamic observation of pulmonary perfusion using continuous arterial spin-labeling in a pig model
    • Roberts DA, Rizi RR, Lipson DA, et al. Dynamic observation of pulmonary perfusion using continuous arterial spin-labeling in a pig model. J Magn Reson Imaging 2001;14:175-180.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 175-180
    • Roberts, D.A.1    Rizi, R.R.2    Lipson, D.A.3
  • 42
    • 0035100421 scopus 로고    scopus 로고
    • Assessment of pulmonary perfusion using a subtracted HASTE image between diastole and systole
    • Tadamura E, Hatabu H. Assessment of pulmonary perfusion using a subtracted HASTE image between diastole and systole. Eur J Radiol 2001;37:179-183.
    • (2001) Eur J Radiol , vol.37 , pp. 179-183
    • Tadamura, E.1    Hatabu, H.2
  • 43
    • 0028466202 scopus 로고
    • Biological magnetic resonance imaging using laser-polarized 129Xe
    • Albert MS, Cates GD, Driehuys B, et al. Biological magnetic resonance imaging using laser-polarized 129Xe. Nature 1994;370:199-201.
    • (1994) Nature , vol.370 , pp. 199-201
    • Albert, M.S.1    Cates, G.D.2    Driehuys, B.3
  • 45
    • 10244222858 scopus 로고    scopus 로고
    • Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging
    • Kauczor HU, Hofmann D, Kreitner KF, et al. Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging. Radiology 1996;201:564-568.
    • (1996) Radiology , vol.201 , pp. 564-568
    • Kauczor, H.U.1    Hofmann, D.2    Kreitner, K.F.3
  • 46
    • 0029907856 scopus 로고    scopus 로고
    • Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging
    • Edelman RR, Hatabu H, Tadamura E, et al. Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging. Nat Med 1996;2:1236-1239.
    • (1996) Nat Med , vol.2 , pp. 1236-1239
    • Edelman, R.R.1    Hatabu, H.2    Tadamura, E.3
  • 47
    • 0345627981 scopus 로고    scopus 로고
    • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol
    • Misselwitz B, Muhler A, Heinzelmann I, et al. Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol. Invest Radiol 1997;32:797-801.
    • (1997) Invest Radiol , vol.32 , pp. 797-801
    • Misselwitz, B.1    Muhler, A.2    Heinzelmann, I.3
  • 48
    • 0023240108 scopus 로고
    • Aerosolized gadolinium-DTPA enhances the magnetic resonance signal of extravascular lung water
    • Montgomery AB, Paajanen H, Brasch RC, et al. Aerosolized gadolinium-DTPA enhances the magnetic resonance signal of extravascular lung water. Invest Radiol 1987;22:377-381.
    • (1987) Invest Radiol , vol.22 , pp. 377-381
    • Montgomery, A.B.1    Paajanen, H.2    Brasch, R.C.3
  • 49
    • 0036240070 scopus 로고    scopus 로고
    • Regional lung functional impairment in acute airway obstruction and pulmonary embolic dog models assessed with gadolinium-based aerosol ventilation and perfusion magnetic resonance imaging
    • Suga K, Ogasawara N, Okada M, et al. Regional lung functional impairment in acute airway obstruction and pulmonary embolic dog models assessed with gadolinium-based aerosol ventilation and perfusion magnetic resonance imaging. Invest Radiol 2002;37:281-291.
    • (2002) Invest Radiol , vol.37 , pp. 281-291
    • Suga, K.1    Ogasawara, N.2    Okada, M.3
  • 51
    • 0032720216 scopus 로고    scopus 로고
    • Pulmonary disorders: Ventilation-perfusion MR imaging with animal models
    • Chen Q, Levin DL, Kim D, et al. Pulmonary disorders: Ventilation-perfusion MR imaging with animal models. Radiology 1999;213: 871-879.
    • (1999) Radiology , vol.213 , pp. 871-879
    • Chen, Q.1    Levin, D.L.2    Kim, D.3
  • 52
    • 0034806908 scopus 로고    scopus 로고
    • Pulmonary ventilation-perfusion MR imaging in clinical patients
    • Nakagawa T, Sakuma H, Murashima S, et al. Pulmonary ventilation-perfusion MR imaging in clinical patients. J Magn Reson Imaging 2001;14:419-424.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 419-424
    • Nakagawa, T.1    Sakuma, H.2    Murashima, S.3
  • 53
    • 0034759082 scopus 로고    scopus 로고
    • MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques
    • Mai VM, Bankier AA, Prasad PV, et al. MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques. J Magn Reson Imaging 2001;14:574-579.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 574-579
    • Mai, V.M.1    Bankier, A.A.2    Prasad, P.V.3
  • 54
    • 0036187987 scopus 로고    scopus 로고
    • Combined MR proton lung perfusion/angiography and helium ventilation: Potential for detecting pulmonary emboli and ventilation defects
    • Zheng J, Leawoods JC, Nolte M, et al. Combined MR proton lung perfusion/angiography and helium ventilation: Potential for detecting pulmonary emboli and ventilation defects. Magn Reson Med 2002;47:433-438.
    • (2002) Magn Reson Med , vol.47 , pp. 433-438
    • Zheng, J.1    Leawoods, J.C.2    Nolte, M.3
  • 55
    • 0033923377 scopus 로고    scopus 로고
    • Laser-polarized (3)He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging
    • Viallon M, Berthezene Y, Decorps M, et al. Laser-polarized (3)He as a probe for dynamic regional measurements of lung perfusion and ventilation using magnetic resonance imaging. Magn Reson Med 2000;44:1-4.
    • (2000) Magn Reson Med , vol.44 , pp. 1-4
    • Viallon, M.1    Berthezene, Y.2    Decorps, M.3
  • 56
    • 0032968308 scopus 로고    scopus 로고
    • Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating: Pilot study
    • Ahlstrom KH, Johansson LO, Rodenburg JB, et al. Pulmonary MR angiography with ultrasmall superparamagnetic iron oxide particles as a blood pool agent and a navigator echo for respiratory gating: Pilot study. Radiology 1999;211:865-869.
    • (1999) Radiology , vol.211 , pp. 865-869
    • Ahlstrom, K.H.1    Johansson, L.O.2    Rodenburg, J.B.3
  • 57
    • 0034806799 scopus 로고    scopus 로고
    • Three-dimensional MR pulmonary perfusion imaging and angiography with an injection of a new blood pool contrast agent B-22956/1
    • Zheng J, Carr J, Harris K, et al. Three-dimensional MR pulmonary perfusion imaging and angiography with an injection of a new blood pool contrast agent B-22956/1. J Magn Reson Imaging 2001;14: 425-432.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 425-432
    • Zheng, J.1    Carr, J.2    Harris, K.3
  • 58
    • 0034846105 scopus 로고    scopus 로고
    • MR perfusion imaging using encapsulated laser-polarized 3He
    • Callot V, Canet E, Brochot J, et al. MR perfusion imaging using encapsulated laser-polarized 3He. Magn Reson Med 2001;46:535-540.
    • (2001) Magn Reson Med , vol.46 , pp. 535-540
    • Callot, V.1    Canet, E.2    Brochot, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.